11714 matches found
Schneider Electric End-of-Life Devices Detection
The current plugin identifies Schneider devices that are end-of-life, i.e., still supported but have a discontinued date announced. Schneider Lifecycle Statuses: - Active: Most current offering within a product category. - End of Life: Discontinued date announced - actively execute migrations and...
Siemens SIMATIC S7-1500 TM MFP Buffer Access with Incorrect Length Value (CVE-2024-42154)
In the Linux kernel, the following vulnerability has been resolved: tcpmetrics: validate source addr length I don't see anything checking that TCPMETRICSATTRSADDRIPV4 is at least 4 bytes long, and the policy doesn't have an entry for this attribute at all neither does it for IPv6 but v6 is manual...
Siemens SCALANCE LPE9403 Improper Neutralization of Special Elements Used in an OS Command (CVE-2025-27398)
Affected devices do not properly neutralize special characters when interpreting user controlled log paths. This could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem. This plugin only works with Tenable.ot...
Siemens SCALANCE LPE9403 Improper Check For Dropped Privileges (CVE-2025-27396)
Affected devices do not properly limit the elevation of privileges required to perform certain valid functionality. This could allow an authenticated lowly-privileged remote attacker to escalate their privileges. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE LPE9403 Improper Neutralization of Special Elements Used in an OS Command (CVE-2025-27392)
Affected devices do not properly sanitize user input when creating new VXLAN configurations. This could allow an authenticated highly- privileged remote attacker to execute arbitrary code on the device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-...
Siemens SCALANCE M-800 and SC-600 Families Partial String Comparison (CVE-2025-23384)
A remote attacker needs to have access to a valid certificate in order to perform a successful attack. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SIMATIC S7-1500 TM MFP Use of Uninitialized Variable (CVE-2024-42161)
In the Linux kernel, the following vulnerability has been resolved: bpf: Avoid uninitialized value in BPFCOREREADBITFIELD. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'...
AI Chatbot DeepSeek R1 Can Be Manipulated to Create Malware
Tenable Research reveals that AI chatbot DeepSeek R1 can be manipulated to generate keyloggers and ransomware code. While…...
Siemens SCALANCE X-200RNA Switch Devices Cryptographic Issues (CVE-2015-0285)
The ssl3clienthello function in s3clnt.c in OpenSSL 1.0.2 before 1.0.2a does not ensure that the PRNG is seeded before proceeding with a handshake, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by sniffing the network and then conducting a brute-force...
Siemens SCALANCE X-200RNA Switch Devices Improper Access Control (CVE-2015-5352)
The x11openhelper function in channels.c in ssh in OpenSSH before 6.9, when ForwardX11Trusted mode is not used, lacks a check of the refusal deadline for X connections, which makes it easier for remote attackers to bypass intended access restrictions via a connection outside of the permitted time...
Siemens SCALANCE X-200RNA Switch Devices Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2015-1789)
The X509cmptime function in crypto/x509/x509vfy.c in OpenSSL before 0.9.8zg, 1.0.0 before 1.0.0s, 1.0.1 before 1.0.1n, and 1.0.2 before 1.0.2b allows remote attackers to cause a denial of service out-of- bounds read and application crash via a crafted length field in ASN1TIME data, as demonstrate...
Siemens SCALANCE X-200RNA Switch Devices Resource Management Errors (CVE-2015-1788)
The BNGF2mmodinv function in crypto/bn/bngf2m.c in OpenSSL before 0.9.8s, 1.0.0 before 1.0.0e, 1.0.1 before 1.0.1n, and 1.0.2 before 1.0.2b does not properly handle ECParameters structures in which the curve is over a malformed binary polynomial field, which allows remote attackers to cause a...
Siemens SIMATIC S7-1500 and S7-1200 Use After Free (CVE-2021-22901)
curl 7.75.0 through 7.76.1 suffers from a use-after-free vulnerability resulting in already freed memory being used when a TLS 1.3 session ticket arrives over a connection. A malicious server can use this in rare unfortunate circumstances to potentially reach remote code execution in the client...
Siemens SCALANCE X-200RNA Switch Devices Out-of-bounds Write (CVE-2016-6303)
Integer overflow in the MDC2Update function in crypto/mdc2/mdc2dgst.c in OpenSSL before 1.1.0 allows remote attackers to cause a denial of service out-of-bounds write and application crash or possibly have unspecified other impact via unknown vectors. This plugin only works with Tenable.ot. Pleas...
Siemens SCALANCE X-200RNA Switch Devices Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2014-8176)
The dtls1clearqueues function in ssl/d1lib.c in OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h frees data structures without considering that application data can arrive between a ChangeCipherSpec message and a Finished message, which allows remote DTLS peers to cause a deni...
Siemens SCALANCE X-200RNA Switch Devices Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2016-10012)
The shared memory manager associated with pre-authentication compression in sshd in OpenSSH before 7.4 does not ensure that a bounds check is enforced by all compilers, which might allows local users to gain privileges by leveraging access to a sandboxed privilege-separation process, related to t...
Siemens SCALANCE X-200RNA Switch Devices Use After Free (CVE-2015-6564)
Use-after-free vulnerability in the mmanswerpamfreectx function in monitor.c in sshd in OpenSSH before 7.0 on non-OpenBSD platforms might allow local users to gain privileges by leveraging control of the sshd uid to send an unexpectedly early MONITORREQPAMFREECTX request. This plugin only works...
Siemens SCALANCE X-200RNA Switch Devices Untrusted Search Path (CVE-2015-8325)
The dosetupenv function in session.c in sshd in OpenSSH through 7.2p2, when the UseLogin feature is enabled and PAM is configured to read .pamenvironment files in user home directories, allows local users to gain privileges by triggering a crafted environment for the /bin/login program, as...
Siemens SCALANCE X-200RNA Switch Devices Observable Discrepancy (CVE-2016-2178)
The dsasignsetup function in crypto/dsa/dsaossl.c in OpenSSL through 1.0.2h does not properly ensure the use of constant-time operations, which makes it easier for local users to discover a DSA private key via a timing side-channel attack. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE X-200RNA Switch Devices Improper Certificate Validation (CVE-2019-1552)
OpenSSL has internal defaults for a directory tree where it can find a configuration file as well as certificates used for verification in TLS. This directory is most commonly referred to as OPENSSLDIR, and is configurable with the --prefix / --openssldir configuration options. For OpenSSL versio...