Lucene search
+L

11881 matches found

Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•6 views

Siemens SIMATIC S7-1500 Improper Handling of Length Parameter Inconsistency (CVE-2024-37371)

In MIT Kerberos 5 aka krb5 before 1.21.3, an attacker can cause invalid memory reads during GSS message token handling by sending message tokens with invalid length fields. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...

9.1CVSS7.3AI score0.01863EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•10 views

Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2020-13434)

SQLite through 3.32.0 has an integer overflow in sqlite3strvappendf in printf.c. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504226;...

5.5CVSS6.9AI score0.01013EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•10 views

Siemens SIMATIC and SCALANCE Improper Input Validation (CVE-2024-7264)

libcurl's ASN1 parser code has the GTime2str function, used for parsing an ASN.1 Generalized Time field. If given an syntactically incorrect field, the parser might end up using -1 for the length of the time fraction, leading to a strlen getting performed on a pointer to a heap buffer area that i...

6.5CVSS6.8AI score0.17301EPSS
SaveExploits1References5
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•13 views

Siemens SIMATIC S7-1500 Improper Initialization (CVE-2024-35830)

In the Linux kernel, the following vulnerability has been resolved: media: tc358743: register v4l2 async device only after successful setup Ensure the device has been setup correctly before registering the v4l2 async device, thus allowing userspace to access. This plugin only works with Tenable.o...

7.8CVSS6.2AI score0.00242EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•13 views

Siemens SIMATIC S7-1500 Missing Encryption of Sensitive Data (CVE-2023-28531)

ssh-add in OpenSSH before 9.3 adds smartcard keys to ssh-agent without the intended per-hop destination constraints. The earliest affected version is 8.9. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

9.8CVSS6.9AI score0.02267EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•9 views

Siemens SIMATIC S7-1500 Use After Free (CVE-2024-49982)

In the Linux kernel, the following vulnerability has been resolved: aoe: fix the potential use-after-free problem in more places For fixing CVE-2023-6270, f98364e92662 aoe: fix the potential use-after- free problem in aoecmdcfgpkts makes tx calling devput instead of doing in aoecmdcfgpkts. It...

8.8CVSS6.8AI score0.00376EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•13 views

Siemens SIMATIC S7-1500 Cleartext Transmission of Sensitive Information (CVE-2023-23915)

A cleartext transmission of sensitive information vulnerability exists in curl v7.88.0 that could cause HSTS functionality to behave incorrectly when multiple URLs are requested in parallel. Using its HSTS support, curl can be instructed to use HTTPS instead of using an insecure clear-text HTTP...

6.5CVSS6.6AI score0.00861EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•7 views

Siemens SIMATIC S7-1500 Encoding Error (CVE-2019-10160)

A security regression of CVE-2019-9636 was discovered in python since commit d537ab0ff9767ef024f26246899728f0116b1ec3 affecting versions 2.7, 3.5, 3.6, 3.7 and from v3.8.0a4 through v3.8.0b1, which still allows an attacker to exploit CVE-2019-9636 by abusing the user and password parts of a URL...

9.8CVSS7.1AI score0.07673EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•14 views

Siemens SIMATIC S7-1500 Cleartext Transmission of Sensitive Information (CVE-2022-43551)

A vulnerability exists in curl 7.87.0 HSTS check that could be bypassed to trick it to keep using HTTP. Using its HSTS support, curl can be instructed to use HTTPS instead of using an insecure clear-text HTTP step even when HTTP is provided in the URL. However, the HSTS mechanism could be bypasse...

7.5CVSS6.6AI score0.1654EPSS
SaveExploits1References5
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•12 views

Siemens SIMATIC S7-1500 Use After Free (CVE-2021-20231)

A flaw was found in gnutls. A use after free issue in client sending keyshare extension may lead to memory corruption and other consequences. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...

9.8CVSS7.3AI score0.03751EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•8 views

Siemens SIMATIC S7-1500 Allocation of Resources Without Limits or Throttling (CVE-2023-23916)

An allocation of resources without limits or throttling vulnerability exists in curl v7.88.0 based on the chained HTTP compression algorithms, meaning that a server response can be compressed multiple times and potentially with differentalgorithms. The number of acceptable links in this...

6.5CVSS6.8AI score0.01703EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•10 views

Generex UPS Adapter CS141 Unrestricted Upload of File with Dangerous Type (CVE-2022-47186)

There is an unrestricted upload of file vulnerability in Generex CS141 below 2.06 version. An attacker could upload and/or delete any type of file, without any format restriction and without any authentication, in the upload directory. This plugin only works with Tenable.ot. Please visit...

9.1CVSS8AI score0.00634EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•14 views

Siemens SIMATIC S7-1500 Use of Incorrectly-Resolved Name or Reference (CVE-2022-27778)

A use of incorrectly resolved name vulnerability fixed in 7.83.1 might remove the wrong file when --no-clobber is used together with --remove-on-error. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

8.1CVSS6.5AI score0.03808EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•24 views

Siemens SIMATIC S7-1500 Out-of-bounds Read (CVE-2024-56650)

In the Linux kernel, the following vulnerability has been resolved: netfilter: xtables: fix LED ID check in ledtgcheck Syzbot has reported the following BUG detected by KASAN This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...

7.1CVSS6.2AI score0.00263EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•17 views

Siemens SIMATIC S7-1500 Use After Free (CVE-2024-56600)

net: inet6: do not leave a dangling sk pointer in inet6create sockinitdata attaches the allocated sk pointer to the provided sock object. If inet6create fails later, the sk object is released, but the sock object retains the dangling sk pointer, which may cause use-after-free later. Clear the soc...

7.8CVSS6.8AI score0.00243EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•10 views

Siemens SIMATIC S7-1500 Cleartext Transmission of Sensitive Information (CVE-2021-22946)

A user can tell curl = 7.20.0 and = 7.20.0 and = 7.78.0 to require a successful upgrade to TLS when speaking to an IMAP, POP3 or FTP server --ssl- reqd on the command line orCURLOPTUSESSL set to CURLUSESSLCONTROL or CURLUSESSLALL withlibcurl. This requirement...

7.5CVSS6.6AI score0.04539EPSS
SaveExploits1References8
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•8 views

Siemens SIMATIC S7-1500 Exposure of Resource to Wrong Sphere (CVE-2019-12904)

In Libgcrypt 1.8.4, the C implementation of AES is vulnerable to a flush-and-reload side-channel attack because physical addresses are available to other processes. The C implementation is used on platforms where an assembly-language implementation is unavailable. NOTE: the vendor's position is...

5.9CVSS6.9AI score0.02063EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•13 views

Siemens SIMATIC S7-1500 Loop with Unreachable Exit Condition (CVE-2017-16932)

parser.c in libxml2 before 2.9.5 does not prevent infinite recursion in parameter entities. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504324...

7.5CVSS6.9AI score0.05928EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•19 views

Siemens SIMATIC S7-1500 Loop with Unreachable Exit Condition (CVE-2024-57884)

mm: vmscan: account for free pages to prevent infinite Loop in throttledirectreclaim The task sometimes continues looping in throttledirectreclaim because allowdirectreclaimpgdat keeps returning false. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-o...

5.5CVSS6.9AI score0.00213EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/13 12:00 a.m.•19 views

Siemens SIMATIC S7-1500 Allocation of Resources Without Limits or Throttling (CVE-2024-28182)

nghttp2 is an implementation of the Hypertext Transfer Protocol version 2 in C. The nghttp2 library prior to version 1.61.0 keeps reading the unbounded number of HTTP/2 CONTINUATION frames even after a stream is reset to keep HPACK context in sync. This causes excessive CPU usage to decode HPACK...

5.3CVSS7AI score0.8496EPSS
SaveExploits1References5
Rows per page
Query Builder