Lucene search
+L

11881 matches found

Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•6 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50295)

net: arc: A warning is shown because ndev-dev and pdev-dev are not the same device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504563;...

5.5CVSS6.9AI score0.00229EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•11 views

Siemens SCALANCE and RUGGEDCOM Devices Integer Overflow or Wraparound (CVE-2024-53145)

um: potential integer overflow during physmem setup. This vulnerability happens when the real map size is greater than LONGMAX, which can be easily triggered on UML/i386. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...

5.5CVSS6.7AI score0.00218EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•12 views

Siemens APOGEE PXC and TALON TC Series Expected Behavior Violation (CVE-2025-40555)

Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted...

5.3CVSS5.8AI score0.00219EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49962)

ACPICA: check null return of ACPIALLOCATEZEROED in acpidbconverttopackage. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504785;...

5.5CVSS6.9AI score0.0025EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•6 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56576)

media: i2c: tc358743: crash in the probe error path when using polling. If an error occurs in the probe function, the polling timer that was alarmed earlier should be removed, otherwise the timer is called with arguments that are already freed, which results in a crash. This plugin only works wit...

7.8CVSS6.9AI score0.00184EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•4 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53227)

scsi: bfa: use-after-free in bfadimmoduleexit. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504501; scriptversion"1.2";...

7.8CVSS7.2AI score0.00278EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•12 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56728)

octeontx2-pf: handle otx2mboxgetrsp errors in otx2ethtool.c. Add error pointer check after calling otx2mboxgetrsp. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...

5.5CVSS6.7AI score0.00212EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•7 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56720)

bpf, sockmap: Several fixes to bpfmsgpopdata, 1. In skmsgshiftleft, it should putpage 2. if len == 0, returning early is better 3. pop the entire skmsg last == msg-sg.size should be supported 4. Fix for the value of variable a 5. In skmsgshiftleft, after shifting, it has already pointed to the ne...

7.8CVSS6.6AI score0.00244EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•11 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42153)

i2c: pnx: potential deadlock warning from deltimersync call in isr. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504657; scriptversion"1.3";...

5.5CVSS6.7AI score0.00182EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•6 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56659)

net: lapb: It is unclear if net/lapb code is supposed to be ready for 8021q, this may lead to crashes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...

5.5CVSS6.8AI score0.00226EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•4 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42105)

nilfs2: use-after-free. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504674; scriptversion"1.3";...

7.8CVSS6.7AI score0.0026EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•12 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50180)

"fbdev: sisfb: Fix strbuf array overflow. The values of the variables xres and yres are placed in strbuf. These variables are obtained from strbuf1. The strbuf1 array contains digit characters and a space if the array contains non-digit characters. Then, when executing sprintfstrbuf, %ux%ux8, xre...

7.8CVSS7.5AI score0.00255EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•9 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56539)

wifi: mwifiex: Fix memcpy field-spanning write warning in mwifiexconfigscan. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504636;...

5.5CVSS6.7AI score0.00296EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•7 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53103)

hvsock: Initializing vsk-trans to NULL to prevent a dangling pointer When hvs is released, there is a possibility that vsk-trans may not be initialized to NULL, which could lead to a dangling pointer. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot...

7.8CVSS6.8AI score0.00238EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•11 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49963)

mailbox: bcm2835: timeout during suspend mode. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504800; scriptversion"1.3";...

5.5CVSS6.9AI score0.00257EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•9 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Initialization (CVE-2024-50193)

x86/entry32: Clear CPU buffers after register restore in NMI return CPU buffers are currently cleared after call to excnmi, but before register state is restored. This may be okay for MDS mitigation but not for RDFS. Because RDFS mitigation requires CPU buffers to be cleared when registers don't...

7.1CVSS7.3AI score0.00215EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•7 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50236)

wifi: ath10k: Fix memory leak in management tx In the current logic, memory is allocated for storing the MSDU context during management packet TX but this memory is not being freed during management TX completion. Similar leaks are seen in the management TX cleanup logic. This plugin only works...

5.5CVSS6.5AI score0.00261EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56633)

tcpbpf: The current sk memory accounting logic in SKREDIRECT is pre-uncharging tosend bytes, which is either msg-sg.size or a smaller value applybytes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

7.8CVSS6.8AI score0.00281EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•8 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40983)

tipc: possible crash before doing decryption. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504584; scriptversion"1.2";...

9.8CVSS6.7AI score0.00881EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2025/11/18 12:00 a.m.•7 views

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49924)

fbdev: pxafb:use after free in pxafbtask. In the pxafbprobe function, it calls the pxafbinitfbinfo function, after which &fbi-task is associated with pxafbtask. Moreover, within this pxafbinitfbinfo function, the pxafbblank function within the &pxafbops struct is capable of scheduling work. If we...

7.8CVSS7.6AI score0.00249EPSS
SaveExploits0References4
Rows per page
Query Builder