11711 matches found
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50024)
net: unsafe loop on the list. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504469; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50179)
ceph: incorrect Fw reference check when dirtying pages. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504801; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53146)
NFSD: Prevent a potential integer overflow If the tag length is = U32MAX - 3 then the length + 4 addition can result in an integer overflow. Address this by splitting the decoding into several steps so that decodecbcompound4res does not have to perform arithmetic on the unsafe length value. This...
Structured Extraction of Vulnerabilities in OpenVAS and Tenable WAS Reports Using LLMs
This paper proposes an automated LLM-based method to extract and structure vulnerabilities from OpenVAS and Tenable WAS scanner reports, converting unstructured data into a standardized format for risk management. In an evaluation using a report with 34 vulnerabilities, GPT-4.1 and DeepSeek...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56698)
usb: dwc3: gadget: looping of queued SG entries The dwc3request-numqueuedsgs is decremented on completion. If a partially completed request is handled, then the dwc3request-numqueuedsgs no longer reflects the total number of numqueuedsgs it would be cleared. This plugin only works with Tenable.ot...
Resource Allocation in Siemens RUGGEDCOM Allocation of Resources Without Limits or Throttling (CVE-2023-39269)
The web server of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause total loss of availability of the web server, which might recover after the attack is over. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Allocation of Resources Without Limits or Throttling (CVE-2024-41009)
bpf: Fix overrunning reservations in ringbuf. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504616; scriptversion"1.3";...
Siemens SIPROTEC Inadequate Encryption Strength (CVE-2024-38867)
The affected devices are supporting weak ciphers on several ports 443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS. This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports. This plugin only...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46740)
binder: UAF caused by offsets overwrite. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504456; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56595)
jfs: add a check to prevent array-index-out-of-bounds in dbAdjTree. When the value of lp is 0 at the beginning of the for loop, it will become negative in the next assignment and we should bail out. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot f...
Siemens SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-47748)
vhostvdpa: assign irq bypass producer token correctly. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504731; scriptversion"1.3";...
Siemens SICAM Q100/Q200 Cleartext Storage of Sensitive Information (CVE-2025-40752)
Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50237)
wifi: mac80211: do not pass a stopped vif to the driver in .gettxpower Avoid potentially crashing in the driver because of uninitialized private data. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56701)
powerpc/pseries: The dtlaccesslock needs to be a rwsempahore, a sleeping lock, because the code calls kmalloc while holding it, which can sleep. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, In...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56700)
media: wl128x: Atomicity violation occurs when the fmcsendcmd function is executed. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504519;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50184)
virtiopmem: Check device status before requesting flush. If a pmem device is in a bad status, the driver side could wait for host ack forever in virtiopmemflush, causing the system to hang. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Siemens RUGGEDCOM Devices Inadequate Encryption Strength (CVE-2021-37209)
The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in- the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. This plugin only works with...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56586)
f2fs: fix f2fsbugon when uninstalling filesystem call f2fsevictinode. creating a large files during checkpoint disable until it runs out of space and then delete it, then remount to enable checkpoint again, and then unmount the filesystem triggers the f2fsbugon. This plugin only works with...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49966)
ocfs2: cancel dqisyncwork before freeing oinfo ocfs2globalreadinfo will initialize and schedule dqisyncwork at the end. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; i...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46755)
wifi: mwifiex: Do not return unused priv in mwifiexgetprivbyid. mwifiexgetprivbyid returns the priv pointer corresponding to the bssnum and bsstype, but without checking if the priv is actually currently in use. Unused priv pointers do not have a wiphy attached to them which can lead to NULL...