93 matches found
PT-2026-32134
Summary Both standalone servers configure CORS with allow origins="", allow credentials=True, allow methods="", and allow headers="". Affected Code python server/key-server/app/main.py:86-92 server/telemetry-server/app/main.py:23-29 app.add middleware CORSMiddleware, allow origins=settings.cors...
PT-2026-32137
Summary A vulnerability in vehicle authentication allows threat actor with valid client credentials i.e., a private key and certificate from a rooted infotainment system to impersonate arbitrary VINs when authenticating to the telemetry server. Impact The attacker would be able to submit falsifie...
CVE-2025-54470
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when...
CVE-2025-54470
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when...
CVE-2025-54470 NeuVector telemetry sender is vulnerable to MITM and DoS
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when...
CVE-2025-54470: Improper Certificate Validation
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when...
PT-2025-43269
Name of the Vulnerable Software and Affected Versions NeuVector versions prior to 5.4.7 Description NeuVector deployments are affected when the Report anonymous cluster data option is enabled. Without TLS certificate verification, the communication channel to the telemetry server at...
EUVD-2020-28104
Malware in sbrugna...
EUVD-2020-28105
Malware in sbrugna...
EUVD-2020-28102
Malware in sbrugna...
EUVD-2020-28106
Malware in sbrugna...
EUVD-2023-23525
Malicious code in bioql PyPI...
CVE-2023-1748
The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server MQTT server and the ability to remotely control garage door...
CVE-2020-6964
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X and CARESCAPE Central Station CSCS Versions 2.X, the integrated service for keyboard switching of the...
CVE-2020-6961
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station CSCS Versions 1.X, a vulnerability exists in the affected products that could allow...
CVE-2020-6965
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability...
CVE-2020-6966
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an...
CVE-2020-6962
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station CSCS Versions 1.X CARESCAPE Central Station CSCS Versions 2.X, B450 Version 2.X, B6...
CVE-2020-6963
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execut...
Improper Check for Unusual or Exceptional Conditions
Overview nipype is a Neuroimaging in Python: Pipelines and Interfaces Affected versions of this package are vulnerable to Improper Check for Unusual or Exceptional Conditions that sends it into a retry loop when the eTelemetry server is unavailable, which may block or delay responses to other...