54 matches found
CVE-2026-48697
Summary: CVE-2026-48697 affects FastNetMon Community Edition up to 1.2.9. The root cause is in execute_web_request_secure() in src/fast_library.cpp, which creates a Boost.Asio TLS client context (tls_client) and calls set_default_verify_paths() but never enables verify_peer. As a result, OpenSSL ...
PT-2026-43312
FastNetMon Community Edition through 1.2.9 does not verify TLS certificates on outbound HTTPS connections. The execute web request secure function in src/fast library.cpp creates a boost::asio::ssl::context with tls client mode and calls set default verify paths to load CA certificates, but never...
CVE-2026-1233
The Text to Speech for WP AI Voices by Mementor plugin for WordPress is vulnerable to sensitive information exposure in all versions up to, and including, 1.9.8. This is due to the plugin containing hardcoded MySQL database credentials for the vendor's external telemetry server in the...
CVE-2026-1233
CVE-2026-1233 affects the WordPress plugin Text to Speech for WP (AI Voices by Mementor). All versions up to 1.9.8 contain hardcoded MySQL credentials for the vendor’s external telemetry server in the Mementor_TTS_Remote_Telemetry class, enabling unauthenticated actors to extract and decode these...
CVE-2025-54470
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when...
CVE-2025-54470
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when...
CVE-2025-54470 NeuVector telemetry sender is vulnerable to MITM and DoS
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when...
EUVD-2020-28106
Malware in sbrugna...
EUVD-2020-28102
Malware in sbrugna...
EUVD-2020-28105
Malware in sbrugna...
EUVD-2020-28104
Malware in sbrugna...
EUVD-2023-23525
Malicious code in bioql PyPI...
CVE-2023-1748
The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server MQTT server and the ability to remotely control garage door...
CVE-2020-6964
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X and CARESCAPE Central Station CSCS Versions 2.X, the integrated service for keyboard switching of the...
CVE-2020-6961
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station CSCS Versions 1.X, a vulnerability exists in the affected products that could allow...
CVE-2020-6965
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability...
CVE-2020-6966
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an...
CVE-2020-6962
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station CSCS Versions 1.X CARESCAPE Central Station CSCS Versions 2.X, B450 Version 2.X, B6...
CVE-2020-6963
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center CIC Versions 4.X and 5.X, CARESCAPE Central Station CSCS Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execut...
Improper Check for Unusual or Exceptional Conditions
Overview nipype is a Neuroimaging in Python: Pipelines and Interfaces Affected versions of this package are vulnerable to Improper Check for Unusual or Exceptional Conditions that sends it into a retry loop when the eTelemetry server is unavailable, which may block or delay responses to other...