775 matches found
PT-2023-1360 · Unknown · Telecontrol Server Basic V3 +2
Name of the Vulnerable Software and Affected Versions: Automation License Manager V5 All versions Automation License Manager V6 All versions prior to V6.0 SP9 Upd4 TeleControl Server Basic V3 All versions prior to V3.1.2 Description: The issue is related to a path traversal vulnerability. It may...
Rapid7 Metasploit 安全漏洞
Rapid7 Metasploit is a suite of penetration testing software from the US-based Rapid7. A security vulnerability exists in Metasploit version 3.11.0.248350, which originates from a module that utilizes the Unified Remote Telecontrol Protocol to enter and deploy payloads.The telecontrol protocol ca...
Siemens Industrial Products with OPC UA
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC NET PC, SITOP Manager, TeleControl Server Basic Vulnerability: Null Pointer Dereference 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory...
Siemens Industrial Products Local Privilege Escalation Vulnerability (Update I)
1. EXECUTIVE SUMMARY CVSS v3 6.4 ATTENTION: Exploitable locally Vendor: Siemens Equipment: Industrial Products Vulnerability: Improper privilege management 2. UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-16-313-02 Siemens Industrial Products Local...
CVE-2019-6575
CVE-2019-6575 affects Siemens industrial products using OPC UA, including SIMATIC CP443-1 OPC UA, ET 200 Open Controller CPU 1515SP PC2, HMI Outdoor Panels (7"/15"), HMI Comfort Panels (4"–22"), KTP Mobile Panels, IPC DiagMonitor, NET PC Software, RF188C, RF600R, S7‑1500 family, WinCC OA/Runtime,...
Siemens Industrial Products with OPC UA (Update H)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC, SINEC-NMS, SINEMA, SINEMURIK Industrial Control Products with OPC UA Vulnerability: Uncaught Exception 2. UPDATE INFORMATION This updated advisory is a follow-up to the...
PT-2019-2034 · Siemens · Simatic Hmi Comfort Outdoor Panels 7" & 15" +16
Name of the Vulnerable Software and Affected Versions: SIMATIC CP 443-1 OPC UA versions prior to the fixed version SIMATIC ET 200SP Open Controller CPU 1515SP PC2 versions prior to V2.7 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15.1 Upd 4 SIMATIC HMI Comfort Panels 4" - 22"...
CVE-2019-6528
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions...
CVE-2019-6528
The CVE-2019-6528 issue affects PSI GridConnect Telecontrol Gateway and Smart Telecontrol Unit family, specifically IEC104 Security Proxy and Telecontrol Gateway variants. The root cause is improper neutralization of input during web page generation, allowing a browser to interpret input as activ...
Code injection
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions...
CVE-2019-6528
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions...
CVE-2019-6528
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions...
PSI GridConnect Telecontrol
1. EXECUTIVE SUMMARY CVSS v3 8.5 ATTENTION: Remotely exploitable/low skill level to exploit Vendor: PSI GridConnect GmbH formerly known as PSI Nentec GmbH Equipment: Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy Vulnerability: Cross-site Scripting 2. RISK EVALUATION...
Siemens TeleControl Server Basic
CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: TeleControl Server Basic Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Permissions, Privileges, and Access Controls, Resource Exhaustion AFFECTED PRODUCTS The following...
Siemens TeleControl Server Basic Authentication Bypass Vulnerability
Siemens TeleControl Server Basic is a remote control system for Siemens equipment from Siemens, Germany. A security vulnerability exists in Siemens TeleControl Server Basic versions prior to 3.1. An attacker could use this vulnerability to bypass the identity access mechanism and read restricted...
Siemens TeleControl Server Basic Denial of Service Vulnerability
Siemens TeleControl Server Basic is a remote control system for Siemens equipment from Siemens, Germany. A security vulnerability exists in Siemens TeleControl Server Basic versions prior to 3.1. An attacker could exploit this vulnerability to cause a denial of service...
Siemens TeleControl Server Basic Elevation of Privilege Vulnerability
Siemens TeleControl Server Basic is a remote control system for Siemens equipment from Siemens, Germany. A security vulnerability exists in Siemens TeleControl Server Basic versions prior to 3.1. An attacker could use this vulnerability to elevate privileges and perform administrative operations...
CVE-2018-4835
A vulnerability has been identified in TeleControl Server Basic V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information...
Race condition
A vulnerability has been identified in TeleControl Server Basic V3.1. An attacker with access to the TeleControl Server Basic's webserver port 80/tcp or 443/tcp could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected...
CVE-2018-4836
A vulnerability has been identified in TeleControl Server Basic V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations...