Lucene search
K

4 matches found

CVE
CVE
added 2018/08/22 6:0 p.m.47 views

CVE-2018-14801

CVE-2018-14801 affects Philips PageWriter TC10/TC20/TC30/TC50/TC70 Cardiographs. The vulnerability arises from hard-coded credentials allowing an attacker who has the superuser password and physical access to enter the superuser password and gain access to/modify all device settings, including re...

7.2CVSS6.2AI score0.00102EPSS
Exploits0References3Affected Software1
CVE
CVE
added 2018/08/22 6:0 p.m.44 views

CVE-2018-14799

CVE-2018-14799 affects Philips PageWriter TC10/TC20/TC30/TC50/TC70 Cardiographs (all versions prior to May 2018). The vulnerability arises from improper input validation / unsanitized user data, enabling potential buffer overflow and format string issues within the device. Impact details in the c...

4.6CVSS4.6AI score0.00163EPSS
Exploits0References3Affected Software1
CNVD
CNVD
added 2018/08/21 12:0 a.m.1 views

Multiple Philips Products Incorrectly Validated Vulnerability

Philips PageWriter TC10 Cardiograph and others are different models of electrocardiograph equipment from Philips Netherlands. A security vulnerability exists in a number of Philips products, which stems from the device not validating user-submitted data. An attacker could exploit the vulnerabilit...

4.6CVSS5.2AI score0.00163EPSS
Exploits0References1
Saint
Saint
added 2010/06/10 12:0 a.m.38 views

Informix Dynamic Server librpc.dll credentials length buffer overflow

Added: 06/10/2010 CVE: CVE-2009-2753 BID: 38471 OSVDB: 62783 Background Informix Dynamic Server is a database solution from IBM. It includes a portmapper service which listens for connections on port 36890/TCP and uses librpc.dll. Problem A buffer overflow vulnerability in librpc.dll allows remot...

10CVSS8AI score0.30501EPSS
Exploits4