Lucene search
+L

6 matches found

RedhatCVE
RedhatCVE
added 2025/08/30 6:18 p.m.9 views

CVE-2025-54492

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch 35a819fa. A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This...

9.8CVSS7.8AI score0.00682EPSS
SaveExploits1References1
Vulnrichment
Vulnrichment
added 2025/08/25 1:53 p.m.2 views

CVE-2025-54492

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch 35a819fa. A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This...

9.8CVSS8.2AI score0.00682EPSS
SaveExploits1References1
CVE
CVE
added 2025/08/25 1:53 p.m.37 views

CVE-2025-54492

A stack-based buffer overflow in The Biosig Project libbiosig 3.9.0 and Master (35a819fa) MFER parsing can be triggered by a crafted MFER file, causing arbitrary code execution. The issue occurs in biosig.c line 9141 on master, when tag==67 (0x43: Sample skew); a local integer skew is overflowed ...

9.8CVSS8.2AI score0.00682EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
added 2025/08/25 1:53 p.m.14 views

CVE-2025-54492

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch 35a819fa. A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This...

9.8CVSS0.00682EPSS
SaveExploits1References1
Debian CVE
Debian CVE
added 2025/08/25 1:53 p.m.11 views

CVE-2025-54492

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch 35a819fa. A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This...

9.8CVSS6.4AI score0.00682EPSS
SaveExploits1
Positive Technologies
Positive Technologies
added 2025/01/01 12:00 a.m.12 views

PT-2025-34646 · Libbiosig +1 · Libbiosig +1

Name of the Vulnerable Software and Affected Versions: libbiosig versions 3.9.0 libbiosig Master Branch 35a819fa Description: A stack-based buffer overflow vulnerability exists in the MFER parsing functionality. A specially crafted MFER file can lead to arbitrary code execution. The vulnerability...

9.8CVSS7.3AI score0.00682EPSS
SaveExploits1References9
Rows per page
Query Builder