Lucene search
+L

444 matches found

CNVD
CNVD
added 2019/12/11 12:00 a.m.16 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45422)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker can...

7.5CVSS7.2AI score0.02502EPSS
SaveExploits1References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.12 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45410)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with...

7.5CVSS7.1AI score0.02475EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.10 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability (CNVD-2019-45424)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02475EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.14 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability (CNVD-2019-45382)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02475EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.12 views

Siemens SPPA-T3000 MS3000 Migration Server Incorrect Access Control Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. It allows an attacker with local...

7.8CVSS6.8AI score0.00315EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.12 views

Siemens SPPA-T3000 Deserialization Untrusted Data Vulnerability

The SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. A security vulnerability exists in the Siemens SPPA-T3000. An attacker could exploit the vulnerability to execute arbitrary code...

9.8CVSS7.4AI score0.05431EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.8 views

Siemens SPPA-T3000 Heap Buffer Overflow Vulnerability

The SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000. An attacker with network access to the MS3000 server could be allowed to cause a denial of service...

9.8CVSS8.3AI score0.02672EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.10 views

Siemens SPPA-T3000 improper authentication vulnerability (CNVD-2019-44767)

The SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. A security vulnerability exists in the Siemens SPPA-T3000. An attacker with network access to the application server could upload arbitrary files without authentication...

7.5CVSS7.1AI score0.01067EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.13 views

Siemens SPPA-T3000 Improper Authentication Vulnerability

The SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. A security vulnerability exists in the Siemens SPPA-T3000. It allows an attacker with network access to the MS3000 server to read and write arbitrary files on the local file...

9.1CVSS6.7AI score0.01181EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.9 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability (CNVD-2019-45384)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02475EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.8 views

Siemens SPPA-T3000 Application Server Improper Authentication Vulnerability (CNVD-2019-45414)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.Application Server is the application server in it, which provides the main system services including access control, distribution of data to thin clients and archiving. A...

5.3CVSS6.7AI score0.0158EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.9 views

Siemens SPPA-T3000 Heap Buffer Overflow Vulnerability (CNVD-2019-44774)

The SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000. This allows an attacker with network access to the MS3000 server to cause a denial of service conditio...

9.8CVSS8.3AI score0.02672EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.15 views

Siemens SPPA-T3000 MS3000 Migration Server Incorrect Access Control Vulnerability (CNVD-2019-45386)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A security vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. It allows an attacker with local...

7.8CVSS6.8AI score0.00315EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.10 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02502EPSS
SaveExploits1References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.9 views

Siemens SPPA-T3000 improper authentication vulnerability (CNVD-2019-44769)

The SPPA-T3000 is a distributed control system mainly used in thermal power plants and large renewable energy power plants. A security vulnerability exists in the Siemens SPPA-T3000. An attacker with network access to the application server could cause a denial of service condition by sending...

7.5CVSS6.7AI score0.01051EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.12 views

Siemens SPPA-T3000 MS3000 Migration Server Heap Buffer Overflow Vulnerability (CNVD-2019-45409)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. A heap buffer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker can...

7.5CVSS7.2AI score0.02475EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.64 views

Siemens SPPA-T3000 Application Server Improper Authentication Vulnerability (CNVD-2019-45374)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.Application Server is the application server in it, which provides the main system services including access control, distribution of data to thin clients and archiving. A...

9.8CVSS8.1AI score0.02295EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.14 views

Siemens SSPPA-T3000 MS3000 Migration Server Out-of-Bounds Read Vulnerability (CNVD-2019-45371)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An out-of-bounds read vulnerability exists in the Siemens SSPPA-T3000 MS3000 Migration Server. An attacker with...

7.5CVSS6.7AI score0.02475EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/12/11 12:00 a.m.11 views

Siemens SPPA-T3000 MS3000 Migration Server Integer Overflow Vulnerability (CNVD-2019-45423)

SPPA-T3000 is a distributed control system mainly used in thermal power plants and large-scale renewable energy power plants.MS3000 Migration Server is one of the migration servers. An integer overflow vulnerability exists in the Siemens SPPA-T3000 MS3000 Migration Server. An attacker with networ...

7.5CVSS6.9AI score0.02475EPSS
SaveExploits0References1
ICS
ICS
added 2019/12/10 12:00 a.m.205 views

Siemens SPPA-T3000 (Update A)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SPPA-T3000 Vulnerabilities: Improper Input Validation, Deserialization of Untrusted Data, Improper Authentication, Cleartext Transmission of Sensitive Information, Unrestricted...

9.8CVSS9.4AI score0.05431EPSS
SaveExploits1References11
Rows per page
Query Builder