Lucene search
+L

2834 matches found

CVE
CVE
added 2023/12/05 6:04 a.m.44 views

CVE-2023-39248

Dell OS10 Networking Switches running 10.5.2.x and above are affected by an Uncontrolled Resource Consumption (Denial of Service) vulnerability when VLT and VRRP are configured. A remote unauthenticated attacker can flood the network, causing outages for legitimate users. Impact is high availabil...

7.5CVSS7.4AI score0.007EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2023/12/05 12:00 a.m.9 views

Dell OS10 Networking Switches 安全漏洞

The Dell Networking OS10 is a switch from Dell USA. A denial of service vulnerability exists in Dell Networking OS10, which can be exploited by an attacker to cause a network outage...

7.5CVSS7.3AI score0.007EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2023/12/04 12:00 a.m.11 views

PT-2023-26847 · Dell · Dell Os10 Networking Switches

Name of the Vulnerable Software and Affected Versions: Dell OS10 Networking Switches versions 10.5.2.x and above Description: The issue is related to an Uncontrolled Resource Consumption Denial of Service vulnerability. When switches are configured with VLT and VRRP, a remote unauthenticated user...

7.5CVSS7.3AI score0.007EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
added 2023/11/22 12:00 a.m.10 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to the use of a rigidly encrypted cryptographic key, allows attackers to gain unauthorized access to protected information.

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software is related to the use of a rigidly encrypted cryptographic key. Exploiting this vulnerability could allow an unauthorized actor to gain unauthorized access to protected information...

6.1CVSS6.3AI score0.00688EPSS
SaveExploits0References3Affected Software40
BDU FSTEC
BDU FSTEC
added 2023/11/22 12:00 a.m.11 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to uncontrolled resource consumption, allows a intruder to trigger a service failure.

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software is related to uncontrolled resource consumption. Exploiting this vulnerability could allow a malicious actor to trigger maintenance failures remotely...

3.3CVSS6.5AI score0.01001EPSS
SaveExploits0References3Affected Software40
BDU FSTEC
BDU FSTEC
added 2023/11/22 12:00 a.m.8 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software relates to unauthorized access to shared data in a multi-threaded context, allowing attackers to gain increased privileges.

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software is related to unsynchronized access to shared data in a multi-threaded context. Exploiting this vulnerability could allow an attacker operating remotely to enhance their privileges...

6.8CVSS7.2AI score0.00666EPSS
SaveExploits0References4Affected Software40
BDU FSTEC
BDU FSTEC
added 2023/11/22 12:00 a.m.13 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to the use of a weak password hash function, allows attackers to modify the device’s configuration.

The vulnerability of Siemens SCALANCE industrial switches’ microprogrammed software is related to the use of a weak password hash function. Exploiting this vulnerability could allow an attacker to remotely modify the device’s configuration...

6.1CVSS6.3AI score0.00446EPSS
SaveExploits0References3Affected Software40
BDU FSTEC
BDU FSTEC
added 2023/11/22 12:00 a.m.8 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to security mechanism errors, allows a intruder to alter the user interface.

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software is related to security mechanism errors. Exploiting this vulnerability could allow a malicious actor to alter the user interface remotely...

4.3CVSS5.4AI score0.00643EPSS
SaveExploits0References3Affected Software40
CNVD
CNVD
added 2023/11/15 12:00 a.m.58 views

Multiple Siemens Products Input Validation Error Vulnerability (CNVD-2023-86591)

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

9.4CVSS6.9AI score0.01352EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2023/11/15 12:00 a.m.51 views

Rockwell Automation Stratix Industrial Managed Ethernet Switch Improper Input Validation (CVE-2018-0174)

A vulnerability in the DHCP option 82 encapsulation functionality of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service DoS condition. The vulnerability exists because the affected...

8.6CVSS7.4AI score0.07793EPSS
SaveExploits0References7
Tenable Nessus
Tenable Nessus
added 2023/11/15 12:00 a.m.26 views

Rockwell Automation Stratix Industrial Managed Ethernet Switch Use of Externally-Controlled Format String (CVE-2018-0175)

A vulnerability in the LLDP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an adjacent, unauthenticated attacker to cause a DoS condition or execute arbitrary code with elevated privileges. This plugin only works with Tenable.ot. Please visit...

8CVSS7.6AI score0.03501EPSS
SaveExploits0References9
Tenable Nessus
Tenable Nessus
added 2023/11/15 12:00 a.m.33 views

Rockwell Automation Stratix Services Router Improper Input Validation (CVE-2018-0158)

A vulnerability in the Internet Key Exchange Version 2 IKEv2 module of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause a memory leak or a reload of an affected device that leads to a denial of service DoS condition. The vulnerability is due to...

8.6CVSS7.2AI score0.07237EPSS
SaveExploits0References6
RedHat Linux
RedHat Linux
added 2023/11/14 3:46 p.m.11 views

kernel: wifi: rtw88: use work to update rate to avoid RCU warning

A flaw was identified in the Linux kernel’s rtw88 Wi-Fi driver drivers/net/wireless/realtek/rtw88 where the ieee80211ops::starcupdate callback was invoked within a Read-Copy-Update RCU read-side critical section without proper atomicity or deferral. The ieee80211chanbwchange function holds an RCU...

8.8CVSS5.9AI score0.00265EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.8 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

8.8CVSS7AI score0.00666EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.9 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

4.3CVSS6.7AI score0.00643EPSS
SaveExploits0References9
Positive Technologies
Positive Technologies
added 2023/11/14 12:00 a.m.11 views

PT-2023-6993 · Siemens · Scalance M826-2 Shdsl-Router +16

Name of the Vulnerable Software and Affected Versions: RUGGEDCOM RM1224 LTE4G EU versions V8.0 RUGGEDCOM RM1224 LTE4G NAM versions V8.0 SCALANCE M804PB versions V8.0 SCALANCE M812-1 ADSL-Router versions V8.0 SCALANCE M816-1 ADSL-Router versions V8.0 SCALANCE M826-2 SHDSL-Router versions V8.0...

5.9CVSS6.6AI score0.00879EPSS
SaveExploits0References11
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.13 views

Siemens SCALANCE 注入漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

9.4CVSS7.1AI score0.01352EPSS
SaveExploits0References8
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.9 views

Siemens SCALANCE 资源管理错误漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

6.5CVSS6.7AI score0.01001EPSS
SaveExploits0References6
IBM Security Bulletins
IBM Security Bulletins
added 2023/11/06 9:23 p.m.43 views

Security Bulletin: Vulnerability in SANNav Software used by IBM b-type SAN directors and switches.

Summary The SANnav Management Portal and Global View products are vulnerable due to a Jave SE issue. The vulnerability has been addressed and can be resolved by applying the SANnav code level listed below. Vulnerability Details CVEID: CVE-2022-21426 DESCRIPTION: An unspecified vulnerability in Ja...

5.3CVSS6.4AI score0.03203EPSS
SaveExploits0Affected Software1
IBM Security Bulletins
IBM Security Bulletins
added 2023/11/06 9:22 p.m.22 views

Security Bulletin: Vulnerability in SANNav Software used by IBM b-type SAN directors and switches.

Summary The SANnav Management Portal and Global View products are vulnerable due to Jave SE issues. The vulnerabilities have been addressed and can be resolved by applying the SANnav code level listed below. Vulnerability Details CVEID: CVE-2023-21830 DESCRIPTION: An unspecified vulnerability in...

5.3CVSS7.2AI score0.01369EPSS
SaveExploits0Affected Software1
Rows per page