Lucene search
+L

5600 matches found

SUSE CVE
SUSE CVE
added 2024/04/15 11:20 p.m.15 views

SUSE CVE-2021-47194

In the Linux kernel, the following vulnerability has been resolved: cfg80211: call cfg80211stopap when switch from P2PGO type If the userspace tools switch from NL80211IFTYPEP2PGO to NL80211IFTYPEADHOC via sendmsgNL80211CMDSETINTERFACE, it does not call the cleanup cfg80211stopap, this leads to t...

5.5CVSS7.5AI score0.00249EPSS
SaveExploits0References14
CVE
CVE
added 2024/04/15 9:37 a.m.92 views

CVE-2024-22438

CVE-2024-22438 affects Hewlett Packard Enterprise OfficeConnect 1820 Network switches. The connected documents indicate a cross-site request forgery (CSRF) vulnerability that could enable remote execution of malicious code. Affected versions include OfficeConnect 1820 switches prior to PT.02.19; ...

3.5CVSS6.9AI score0.00206EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/04/15 12:0 a.m.8 views

Hewlett Packard Enterprise FlexFabric 和 FlexNetwork 安全漏洞

Hewlett Packard Enterprise FlexNetwork HPE FlexFabric and Hewlett Packard Enterprise FlexFabric HPE FlexFabric are both part of a series of switches from the U.S. firm Hewlett Packard Hewlett Packard Enterprise FlexFabric and Hewlett Packard Enterprise FlexFabric are a family of switches from...

6.9CVSS6.5AI score0.002EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/04/15 12:0 a.m.13 views

Hewlett Packard Enterprise OfficeConnect 安全漏洞

Hewlett Packard Enterprise OfficeConnect is a series of switches from Hewlett Packard Enterprise USA. A security vulnerability exists in the Hewlett Packard Enterprise OfficeConnect 1820 Network switches that stems from the presence of a cross-site request forgery CSRF vulnerability. An attacker...

3.5CVSS6.8AI score0.00206EPSS
SaveExploits0References2
OSV
OSV
added 2024/04/12 3:15 p.m.10 views

CVE-2024-30410

An Incorrect Behavior Order in the routing engine RE of Juniper Networks Junos OS on EX4300 Series allows traffic intended to the device to reach the RE instead of being discarded when the discard term is set in loopback lo0 interface. The intended function is that the lo0 firewall filter takes...

6.9CVSS5.8AI score0.00363EPSS
SaveExploits0References2
NVD
NVD
added 2024/04/11 1:25 a.m.21 views

CVE-2024-2740

Information exposure vulnerability in Planet IGS-4215-16T2S, affecting firmware version 1.305b210528. This vulnerability could allow a remote attacker to access some administrative resources due to lack of proper management of the Switch web interface...

7.7CVSS7.5AI score0.00348EPSS
SaveExploits0References1
NVD
NVD
added 2024/04/11 1:25 a.m.22 views

CVE-2024-2741

Cross-Site Request Forgery CSRF vulnerability in Planet IGS-4215-16T2S, affecting firmware version 1.305b210528. This vulnerability could allow a remote attacker to trick some authenticated users into performing actions in their session, such as adding or updating accounts through the Switch web...

7.1CVSS6.9AI score0.00225EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/04/11 12:0 a.m.35 views

Planet IGS-4215-16T2S 信息泄露漏洞

The Planet IGS-4215-16T2S is an industrial grade switching device. The Planet IGS-4215-16T2S suffers from an information disclosure vulnerability that stems from a lack of proper management of the Switch web interface. An attacker can exploit this vulnerability to obtain sensitive information...

7.7CVSS6.1AI score0.00348EPSS
SaveExploits0References2
NVD
NVD
added 2024/04/10 7:15 p.m.24 views

CVE-2021-47194

In the Linux kernel, the following vulnerability has been resolved: cfg80211: call cfg80211stopap when switch from P2PGO type If the userspace tools switch from NL80211IFTYPEP2PGO to NL80211IFTYPEADHOC via sendmsgNL80211CMDSETINTERFACE, it does not call the cleanup cfg80211stopap, this leads to t...

7.8CVSS7.3AI score0.00249EPSS
SaveExploits0References8
UbuntuCve
UbuntuCve
added 2024/04/10 7:15 p.m.19 views

CVE-2021-47194

In the Linux kernel, the following vulnerability has been resolved: cfg80211: call cfg80211stopap when switch from P2PGO type If the userspace tools switch from NL80211IFTYPEP2PGO to NL80211IFTYPEADHOC via sendmsgNL80211CMDSETINTERFACE, it does not call the cleanup cfg80211stopap, this leads to t...

7.8CVSS6.1AI score0.00249EPSS
SaveExploits0References11
OSV
OSV
added 2024/04/10 7:15 p.m.16 views

UBUNTU-CVE-2021-47194

In the Linux kernel, the following vulnerability has been resolved: cfg80211: call cfg80211stopap when switch from P2PGO type If the userspace tools switch from NL80211IFTYPEP2PGO to NL80211IFTYPEADHOC via sendmsgNL80211CMDSETINTERFACE, it does not call the cleanup cfg80211stopap, this leads to t...

7.8CVSS6AI score0.00249EPSS
SaveExploits0References12
SUSE CVE
SUSE CVE
added 2024/04/09 2:29 a.m.8 views

SUSE CVE-2024-26683

In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: detect stuck ECSA element in probe resp We recently added some validation that we don't try to connect to an AP that is currently in a channel switch process, since that might want the channel to be quiet or we...

5.5CVSS6.4AI score0.00193EPSS
SaveExploits0References10
SUSE CVE
SUSE CVE
added 2024/04/09 2:29 a.m.6 views

SUSE CVE-2024-26682

In the Linux kernel, the following vulnerability has been resolved: wifi: mac80211: improve CSA/ECSA connection refusal As mentioned in the previous commit, we pretty quickly found that some APs have ECSA elements stuck in their probe response, so using that to not attempt to connect while CSA is...

5.5CVSS6.5AI score0.00193EPSS
SaveExploits0References10
Vulnrichment
Vulnrichment
added 2024/04/05 2:33 a.m.16 views

CVE-2023-5973 Truncated port name

Brocade Web Interface in Brocade Fabric OS v9.x and before v9.2.0 does not properly represent the portName to the user if the portName contains reserved characters. This could allow an authenticated user to alter the UI of the Brocade Switch and change ports display...

4.3CVSS4.5AI score0.00178EPSS
SaveExploits0References2
NVD
NVD
added 2024/04/04 5:15 p.m.24 views

CVE-2023-3454

Remote code execution RCE vulnerability in Brocade Fabric OS after v9.0 and before v9.2.0 could allow an attacker to execute arbitrary code and use this to gain root access to the Brocade switch...

9.8CVSS9.1AI score0.01205EPSS
SaveExploits1References2
Cvelist
Cvelist
added 2024/04/04 5:3 p.m.40 views

CVE-2023-3454

Remote code execution RCE vulnerability in Brocade Fabric OS after v9.0 and before v9.2.0 could allow an attacker to execute arbitrary code and use this to gain root access to the Brocade switch...

8.6CVSS9.2AI score0.01205EPSS
SaveExploits1References2
CVE
CVE
added 2024/04/04 5:3 p.m.73 views

CVE-2023-3454

CVE-2023-3454 is a remote code execution flaw in Brocade Fabric OS that affects versions after 9.0 and before 9.2.0. An unauthenticated attacker could execute arbitrary code and gain root access on affected Brocade Fibre Channel switches. Documented impact is high to critical, with disclosures in...

9.8CVSS9.1AI score0.01205EPSS
SaveExploits1References2Affected Software1
Broadcom
Broadcom
added 2024/04/04 12:0 a.m.37 views

Truncated port name (CVE-2023-5973)

Brocade Web Interface in Brocade Fabric OS v9.x and before v9.2.0 does not properly represent the portName to the user if the portName contains reserved characters. This could allow an authenticated user to alter the UI of the Brocade Switch and change ports display. Note: The vulnerability doesn...

4.3CVSS6.6AI score0.00178EPSS
SaveExploits0Affected Software1
Debian CVE
Debian CVE
added 2024/04/03 5:0 p.m.59 views

CVE-2024-26747

In the Linux kernel, the following vulnerability has been resolved: usb: roles: fix NULL pointer issue when put module's reference In current design, usb role class driver will get usbroleswitch parent's module reference after the user get usbroleswitch device and put the reference after the user...

4.4CVSS6.1AI score0.00238EPSS
SaveExploits0
RedhatCVE
RedhatCVE
added 2024/04/03 12:3 a.m.23 views

CVE-2024-26683

A vulnerability was found in the Linux kernel. This issue occurs when an AP continually advertises a stuck ECSA element, leading to incorrect channel switch process handling. This can lead to network connectivity issues if the AP is stuck in a state where it continuously advertises a false channe...

5.5CVSS8.1AI score0.00193EPSS
SaveExploits0References4
Rows per page
Query Builder