7 matches found
PT-2025-48405
opening the vault on a 3-year-old vulnerability: CVE-2022-35420 back in 2022, I got bored and decided to hunt for a zero-day instead of writing the red-team report. I found an unauthenticated admin takeover in a SCADA system used to control real-world physical machinery. I waited until now to...
The vulnerability of the OPC Server implementation in MIR and SCADA systems, related to the transmission of data in an open manner, allows attackers to disclose protected information.
The vulnerability of the OPC Server implementation and the MIIR SCADA system is related to the transmission of data in an open manner. Exploiting this vulnerability can allow a malicious actor to disclose the protected information...
Triangle MicroWorks SCADA Data Gateway 安全漏洞
Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle MicroWorks, Inc. A security vulnerability exists in Triangle MicroWorks SCADA Data Gateway that originates from a specific flaw in workspace files that allows remote attackers to create arbitrary files...
The vulnerability of the get_config component of the data exchange software between SCADA systems, such as Triangle MicroWorks SCADA Data Gateway (SDG), allows a intruder to bypass security restrictions and gain unauthorized access to the system.
The vulnerability of the getconfig component of the data exchange software between SCADA systems is related to deficiencies in authentication procedures. Exploiting this vulnerability allows an intruder to bypass security restrictions and gain unauthorized access to the system...
The vulnerability of the SCADA system “SKADA-NEV” arises from the storage of critical information in unencrypted form, allowing attackers to gain access to confidential data.
The vulnerability of the SCADA system “SKADA-NEV” is related to the storage of critical information in unencrypted form. Exploiting this vulnerability can allow an intruder to gain access to confidential information...
The vulnerability of the “bdate” parameter in the xhisvalue.htm component of the HMI/SCADA application xArrow allows attackers to perform cross-site scripting attacks.
The vulnerability of the “bdate” parameter in the xhisvalue.htm component of the HMI/SCADA application xArrow is related to the lack of measures taken to protect the web page structure. Exploiting this vulnerability could allow a malicious actor to perform cross-site scripting attacks remotely...
Racom 安全漏洞
The RACOM M!DGE is a cellular router designed for SCADA and telemetry mission-critical applications and is ideally suited for many different wireless applications. An OS command injection vulnerability exists in the RACOM M!DGE firmware version 4.4.40.105. An attacker can exploit this vulnerabili...