52 matches found
EUVD-2021-34684
Malicious code in bioql PyPI...
CVE-2021-4459
An authorized remote attacker can access files and directories outside the intended web root, potentially exposing sensitive system information of the affected Sunny Boy devices...
CVE-2021-4459
An authorized remote attacker can access files and directories outside the intended web root, potentially exposing sensitive system information of the affected Sunny Boy devices...
CVE-2021-4459 SMA: Directory Traversal in Sunny Boy <3.10.27.R
An authorized remote attacker can access files and directories outside the intended web root, potentially exposing sensitive system information of the affected Sunny Boy devices...
CVE-2021-4459
CVE-2021-4459 is a directory traversal vulnerability in SMA Sunny Boy inverters. The issue allows an authenticated remote attacker to access files/directories outside the web root, potentially exposing sensitive system information on affected Sunny Boy devices. The CVE is described with the title...
PT-2025-34841 · Sma Solar Technology · Sunny Boy
Name of the Vulnerable Software and Affected Versions: Sunny Boy affected versions not specified Description: An authorized remote attacker can access files and directories outside the intended web root, potentially exposing sensitive system information of the affected devices. Recommendations: A...
SMA Solar Technology AG Sunny Boy 安全漏洞
SMA Solar Technology AG Sunny Boy is a photovoltaic inverter from SMA Solar Technology AG, Germany. A security vulnerability exists in the SMA Solar Technology AG Sunny Boy that stems from improper access control and could lead to the disclosure of sensitive system information...
Information disclosure
DISPUTED An issue was discovered in SMA Solar Technology products. When signed into Sunny Explorer with a wrong password, it is possible to create a debug report, disclosing information regarding the application and allowing the attacker to create and save a .txt file with contents to his liking...
Authentication flaw
DISPUTED An issue was discovered in SMA Solar Technology products. The SIP implementation does not properly use authentication with encryption: it is vulnerable to replay attacks, packet injection attacks, and man in the middle attacks. An attacker is able to successfully use SIP to communicate...
CVE-2017-9861
An issue was discovered in SMA Solar Technology products. The SIP implementation does not properly use authentication with encryption: it is vulnerable to replay attacks, packet injection attacks, and man in the middle attacks. An attacker is able to successfully use SIP to communicate with the...
CVE-2017-9857
An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, etc. can be...
Default credentials
DISPUTED An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline cracker...
CVE-2017-9851
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...
CVE-2017-9863
An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cross-site request forgery can be used to change settings in the inverters for example, issuing a POST request to change the user password. All Sunny Explorer...
CVE-2017-9862
An issue was discovered in SMA Solar Technology products. When signed into Sunny Explorer with a wrong password, it is possible to create a debug report, disclosing information regarding the application and allowing the attacker to create and save a .txt file with contents to his liking. An...
CVE-2017-9854
An issue was discovered in SMA Solar Technology products. By sniffing for specific packets on the localhost, plaintext passwords can be obtained as they are typed into Sunny Explorer by the user. These passwords can then be used to compromise the overall device. NOTE: the vendor reports that...
CVE-2017-9853
An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of...
Authentication flaw
DISPUTED An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the...
Design/Logic Flaw
DISPUTED An issue was discovered in SMA Solar Technology products. By sniffing for specific packets on the localhost, plaintext passwords can be obtained as they are typed into Sunny Explorer by the user. These passwords can then be used to compromise the overall device. NOTE: the vendor reports...
CVE-2017-9855
An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...