14 matches found
EUVD-2013-2760
Malware in sbrugna...
EUVD-2013-2761
Malware in sbrugna...
An Advanced Cyber-Physical System Security Testbed for Substation Automation
A Cyber-Physical System CPS testbed serves as a powerful platform for testing and validating cyber intrusion detection and mitigation strategies in substations. This study presents the design and development of a CPS testbed that can effectively assess the real-time dynamics of a substation. Cybe...
The vulnerability of the microprogrammed control module software for Schneider Electric Easergy T300 (HU250) automation systems, related to the use of vulnerable external software, allows attackers to carry out various attacks on these components.
The vulnerability of the microprogramming software of the modular controller for the automation of transformer substations of Schneider Electric Easergy T300 HU250 is related to the use of a vulnerable external software. Exploiting this vulnerability allows a malicious actor to carry out various...
ABB MicroSCADA Pro SYS600 Access Control Error Vulnerability
ABB MicroSCADA Pro SYS600 is a suite of monitoring and data acquisition software from ABB Switzerland. The software is used for substation automation, SCADA electrical, distribution management applications and industrial power management. An access control error vulnerability exists in ABB...
Sifang CSI-200EA Measurement and Control Device IP Protocol Segmentation Denial of Service Vulnerability
CSI-200EA measurement and control device is mainly used in substation automation system of 110kV and above voltage level. A denial of service vulnerability exists in the IP protocol fragmentation of the Sifang CSI-200EA measurement and control device. An attacker can cause the network function of...
Denial of Service Vulnerability in MMS Protocol for Sifang CSI-200EA Measurement and Control Device
CSI-200EA measurement and control device is mainly used in substation automation system of 110kV and above voltage level. A denial of service vulnerability exists in the MMS protocol of the Sifang CSI-200EA measurement and control device. An attacker can exploit the vulnerability to cause a devic...
SIEMENS SICAM PAS Security Bypass Vulnerability (CNVD-2016-11836)
SICAM PAS is an energy automation solution for the operation of substation equipment. It has open communication interfaces for power system control and control of industrial power supply equipment. A security bypass vulnerability exists in SIEMENS SICAM PAS. A remote attacker can exploit the...
SIEMENS SICAM PAS Local Security Bypass Vulnerability
SICAM PAS is an energy automation solution for the operation of substation equipment. It has open communication interfaces for power system control and control of industrial power supply equipment. A local security bypass vulnerability exists in SIEMENS SICAM PAS. An authenticated local attacker...
Siemens SICAM PAS Information Disclosure Vulnerability
SICAM PAS is an energy automation solution for the operation of substation equipment. It has open communication interfaces for power system control and control of industrial power supply equipment. An information disclosure vulnerability exists in Siemens SICAM PAS. An attacker with privileged...
CVE-2013-2822
NovaTech Orion Substation Automation Platform OrionLX DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier and Orion5/Orion5r DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier allow physically proximate attackers to cause a denial of service driver crash and process restart via crafted input...
CVE-2013-2822
NovaTech Orion Substation Automation Platform (OrionLX: Master 1.27.38 / Slave 1.23.10 and earlier; Orion5/Orion5r Master 1.27.38 / Slave 1.23.10 and earlier) contains a denial-of-service vulnerability when processing crafted input over a serial line, causing the Orion driver to crash and the pro...
CVE-2013-2821
NovaTech Orion Substation Automation Platform (OrionLX DNP Master 1.27.38 / DNP Slave 1.23.10 and Orion5/Orion5r 1.27.38 / 1.23.10 and earlier) contains an improper input validation vulnerability in the DNP3 implementation that can cause the Orion Process to restart (driver crash) when processing...
ABB RTU560 Substation Automation Detection
Binary data 6756.prm...