15 matches found
StruxureWare SCADA Expert ClearSCADA Weak Hashing Algorithm
Binary data scadaclearscadaweakhashingalgorithm.nbin...
CVE-2014-5411
Multiple cross-site scripting XSS vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors...
PT-2014-6458
Name of the Vulnerable Software and Affected Versions Schneider Electric StruxureWare SCADA Expert ClearSCADA versions 2010 R3 through 2014 R1 Description The issue allows remote authenticated users to inject arbitrary web script or HTML via unspecified vectors, which can lead to multiple...
CVE-2014-5411: Improper Neutralization of Input During Web Page Generation
Multiple cross-site scripting XSS vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors...
CVE-2014-5413: Undefined Security Weakness
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm...
PT-2014-6460
Name of the Vulnerable Software and Affected Versions Schneider Electric StruxureWare SCADA Expert ClearSCADA versions 2010 R3 through 2014 R1 Description The issue concerns the use of the MD5 algorithm for an X.509 certificate, which can be exploited by remote attackers to spoof servers via a...
CVE-2014-5412: Improper Authentication
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account...
PT-2014-6459
Name of the Vulnerable Software and Affected Versions Schneider Electric StruxureWare SCADA Expert ClearSCADA versions 2010 R3 through 2014 R1 Description The issue allows remote attackers to read database records by leveraging access to the guest account. Recommendations For versions 2010 R3...
CVE-2014-0779
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
CVE-2014-0779 Schneider Electric StruxureWare SCADA Expert ClearSCADA Improper Restriction of Operations within the Bounds of a Memory Buffer
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
PT-2014-3839
Name of the Vulnerable Software and Affected Versions Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA versions 2010 R2 build 71.4165 through 2013 R2 build 74.5094 Description The issue allows remote attackers to cause a denial of service, resulting in an...
CVE-2014-0779: Improper Restriction of Operations within the Bounds of a Memory Buffer
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
CVE-2013-2824
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to...
StruxureWare SCADA Expert ClearSCADA Detection
Binary data scadaappclearscadainstalled.nbin...
CVE-2013-2824: Undefined Security Weakness
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to...