Lucene search
+L

126 matches found

ThreatPost
ThreatPost
added 2014/11/11 12:40 p.m.17 views

Stuxnet's First Five Victims Provided Path to Natanz

Stuxnet’s first five victims were a carefully crafted list of targets that ultimately provided the attackers with the road map they needed to get inside a uranium enrichment plant in Natanz, Iran and disrupt the country’s nuclear program. Cobbled together from clues left behind by the infamous...

1.3AI score
SaveExploits0References1
ICS
ICS
added 2014/01/08 12:00 p.m.248 views

USB Malware Targeting Siemens Control Software (Update C)

Overview VirusBlokAda, an antivirus vendor based in Belarus, announcedVirusBlokAda, http://www.anti-virus.by/en/tempo.shtml, website last visited July 15, 2010. the discovery of malware that uses a zero-day vulnerability in Microsoft Windows processing of shortcut files. The malware utilizes this...

9.3CVSS8AI score0.91324EPSS
SaveExploits14References24
Cvelist
Cvelist
added 2013/04/02 10:00 a.m.42 views

CVE-2013-2741

importbuddy.php in the BackupBuddy plugin 1.3.4, 2.1.4, 2.2.25, 2.2.28, and 2.2.4 for WordPress does not require that authentication be enabled, which allows remote attackers to obtain sensitive information, or overwrite or delete files, via vectors involving a 1 direct request, 2 step=1 request,...

6.7AI score0.02563EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
added 2012/09/21 12:00 a.m.20 views

PT-2015-10: Privilege Gaining in Siemens SIMATIC STEP 7 (TIA Portal)

The specialists of the Positive Research center have detected a Privilege Gaining vulnerability in Siemens SIMATIC STEP 7 TIA Portal. Vulnerability exists in TIA Portal due to improper integrity protection of project-file fields containing user’s privileges, which allows attackers to modify user...

4.4CVSS6.6AI score0.00512EPSS
SaveExploits0References5
ICS
ICS
added 2012/04/26 6:00 a.m.71 views

Siemens SIMATIC STEP 7 DLL Vulnerability

Overview Siemens has released a software update for a DLL hijacking vulnerability in SIMATIC STEP 7 and SIMATIC PCS 7 software. Previous versions of SIMATIC STEP 7 and PCS 7 allowed the loading of malicious DLL files into the STEP 7 project folder that can be used to attack the system on which ST...

6.9CVSS7.5AI score0.00455EPSS
SaveExploits0References10
ThreatPost
ThreatPost
added 2011/08/08 2:44 p.m.27 views

Dillon Beresford Talked Siemens Vulnerabilities

NSS researcher Dillon Beresford continued his research into the security of SCADA and industrial control systems with a talk on vulnerabilities in Siemens Step 7 programmable logic controllers. Read more: Black Hat: Remote DOS, Backdoor, Easter Egg Among Newly Discovered Siemens Holes...

2.8AI score
SaveExploits0References1
Rows per page