6961 matches found
CVE-2024-25176
LuaJIT through 2.1 and OpenRusty luajit2 before v2.1-20240626 have a stack-buffer-overflow in ljstrfmtwfnum in ljstrfmtnum.c...
CVE-2024-25176
LuaJIT through 2.1 and OpenRusty luajit2 before v2.1-20240626 have a stack-buffer-overflow in ljstrfmtwfnum in ljstrfmtnum.c...
CVE-2024-25176
LuaJIT through 2.1 and OpenRusty luajit2 before v2.1-20240626 have a stack-buffer-overflow in ljstrfmtwfnum in ljstrfmtnum.c...
LuaJIT 安全漏洞
LuaJIT is a LuaJIT open source on-the-fly compiler for the Lua language. A security vulnerability exists in LuaJIT 2.1 and earlier versions, which stems from a stack buffer overflow in the ljstrfmtwfnum function in ljstrfmtnum.c. The vulnerability is caused by a stack buffer overflow in the...
CVE-2024-25176
LuaJIT through 2.1 and OpenRusty luajit2 before v2.1-20240626 have a stack-buffer-overflow in ljstrfmtwfnum in ljstrfmtnum.c...
CVE-2025-7091
A vulnerability was found in Belkin F9K1122 1.00.33. It has been classified as critical. Affected is the function formWlanMP of the file /goform/formWlanMP of the component webs. The manipulation of the argument...
CVE-2025-7090
A vulnerability, which was classified as critical, has been found in Belkin F9K1122 1.00.33. Affected by this issue is the function formConnectionSetting of the file /goform/formConnectionSetting of the component webs. The manipulation of the argument maxConn/timeOut leads to stack-based buffer...
Belkin F9K1122 安全漏洞
The Belkin F9K1122 is a WiFi signal extender from Belkin Canada. The Belkin F9K1122 suffers from a stack buffer overflow vulnerability that originates from the incorrect operation of the parameter pinCode in the file /goform/formWpsStart, no details of the vulnerability are provided at this time...
Belkin F9K1122 安全漏洞
The Belkin F9K1122 is a WiFi signal extender. The Belkin F9K1122 suffers from a stack buffer overflow vulnerability that results from the incorrect operation of the parameter submit-url-ok in the file /goform/formBSSetSitesurvey. No detailed vulnerability details are provided at this time...
Belkin F9K1122 安全漏洞
The Belkin F9K1122 is a WiFi signal extender. The Belkin F9K1122 suffers from a stack buffer overflow vulnerability that originates from the incorrect operation of the parameter submit-url-ok in the file /goform/formBSSetSitesurvey, for which no detailed vulnerability details are provided...
Tenda AC5 Stack Buffer Overflow Vulnerability (CNVD-2025-15273)
Tenda AC5 is a wireless router from Tenda, a Chinese company. The Tenda AC5 suffers from a stack buffer overflow vulnerability, which originates from the failure of the parameters time and timeZone in the file /goform/SetSysTimeCfg to correctly validate the length of the input data, which can be...
The vulnerability of the OAM service of the Nokia Single RAN network management platform allows a attacker to cause a service failure.
The vulnerability of the OAM service of the Nokia Single RAN network management platform is related to buffer overflow in the stack. Exploiting this vulnerability could allow a malicious actor to cause service interruptions...
SUSE SLES12: libicu-devel / libicu-doc / libicu52_1 / libicu52_1-32bit / etc (SUSE-SU-2025:02216-1)
The remote SUSE Linux SLES12 host has packages installed that are affected by a vulnerability as referenced in the SUSE- SU-2025:02216-1 advisory. - CVE-2025-5222: Fixed stack buffer overflow in the SRBRoot:addTag function bsc1243721 Tenable has extracted the preceding description block directly...
CVE-2025-6072 Stack Buffer Overflow in MQTTCore
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.Thi...
CVE-2025-6072 Stack Buffer Overflow in MQTTCore
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.Thi...
CVE-2025-6072
CVE-2025-6072 affects ABB RMC-100 and RMC-100 LITE. The root cause is a stack-based buffer overflow in the REST interface when processing JSON configuration, enabling overflow of the expiration date field (and related CVE-2025-6074 flow). Impact cited includes potential denial of service and expo...
CVE-2025-6073 Stack Buffer Overflow in MQTTCore
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer...
CVE-2025-6073
CVE-2025-6073 is a stack-based buffer overflow in ABB RMC-100 and RMC-100 LITE caused by REST interface exposure. It affects RMC-100 builds 2105457-043 to 2105457-045 and RMC-100 LITE builds 2106229-015 to 2106229-016. The issue is tied to CVE-2025-6074, which describes a related hard-coded key v...
CVE-2025-6073 Stack Buffer Overflow in MQTTCore
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer...