13294 matches found
CVE-2024-23138
A maliciously crafted DWG file when parsed through Autodesk DWG TrueView can be used to cause a Stack-based Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process...
CVE-2024-1941
Delta Electronics CNCSoft-B versions 1.0.0.4 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code...
CVE-2024-1783
A vulnerability classified as critical has been found in Totolink LR1200GB 9.1.0u.6619B20230130/9.3.5u.6698B20230810. Affected is the function loginAuth of the file /cgi-bin/cstecgi.cgi of the component Web Interface. The manipulation of the argument httphost leads to stack-based buffer overflow...
CVE-2024-1002
A vulnerability classified as critical was found in Totolink N200RE 9.3.5u.6139B20201216. Affected by this vulnerability is the function setIpPortFilterRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ePort leads to stack-based buffer overflow. The attack can be launched...
CVE-2024-1004
A vulnerability, which was classified as critical, was found in Totolink N200RE 9.3.5u.6139B20201216. This affects the function loginAuth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument httphost leads to stack-based buffer overflow. It is possible to initiate the attack remotel...
CVE-2024-1001
A vulnerability classified as critical has been found in Totolink N200RE 9.3.5u.6139B20201216. Affected is the function main of the file /cgi-bin/cstecgi.cgi. The manipulation leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the...
CVE-2024-1003
A vulnerability, which was classified as critical, has been found in Totolink N200RE 9.3.5u.6139B20201216. Affected by this issue is the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument lang leads to stack-based buffer overflow. The attack may be launched...
CVE-2024-10123
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compareparentcontroltime of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be...
CVE-2024-10130
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. Th...
CVE-2024-10661
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit...
CVE-2024-10283
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched...
CVE-2024-10351
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack...
CVE-2024-10434
A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ateTendamfgcheckusb/ateTendamfgcheckusb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attac...
CVE-2024-10281
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotel...
CVE-2024-10698
A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The...
CVE-2024-36290
A buffer overflow vulnerability exists in the login.cgi Gotochidx functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to stack-based buffer overflow. An attacker can make an unauthenticated HTTP request to trigger this vulnerability...
CVE-2024-6965
A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has be...
CVE-2024-6963
A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the publi...
CVE-2024-24963
A stack-based buffer overflow vulnerability exists in the Programming Software Connection FileSelect functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to stack-based buffer overflow. An attacker can send an unauthenticated packet to trigger this...
CVE-2024-2489
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has...