17432 matches found
CVE-2024-2893: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The...
CVE-2024-2892: Stack-based Buffer Overflow
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The explo...
PT-2024-2597
Name of the Vulnerable Software and Affected Versions Tenda AC7 version 15.03.06.44 Description A critical issue affects the formWifiWpsOOB function of the /goform/WifiWpsOOB file, caused by a stack-based buffer overflow. The manipulation of the index argument leads to this overflow. The attack c...
CVE-2024-25137: Stack-based Buffer Overflow
In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which may lead to a stack overflow. The result of this stack-based buffer overflow can lead to denial-of-service conditions...
CVE-2023-51148: Stack-based Buffer Overflow
An issue in TRENDnet Trendnet AC1200 Dual Band PoE Indoor Wireless Access Point TEW-821DAP v.3.00b06 allows an attacker to execute arbitrary code via the 'mycli' command-line interface component...
CVE-2024-2895: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The explo...
openSUSE: Security Advisory for vim (SUSE-SU-2024:0871-1)
The remote host is missing an update for the SPDX-FileCopyrightText: 2024 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
CVE-2024-2856
The CVE-2024-2856 vulnerability affects Tenda AC10 firmware 16.03.10.13/16.03.10.20. The issue is in the function fromSetSysTime of /goform/SetSysTimeCfg, where manipulating the timeZone parameter causes a stack-based buffer overflow. It can be triggered remotely and public exploits have been dis...
CVE-2024-2855
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched...
CVE-2024-2852
A vulnerability was found in Tenda AC15 15.03.20multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated...
CVE-2024-2850 Tenda AC15 saveParentControlInfo stack-based overflow
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely...
CVE-2024-2850 Tenda AC15 saveParentControlInfo stack-based overflow
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely...
CVE-2024-2856: Stack-based Buffer Overflow
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be...
CVE-2024-2855: Stack-based Buffer Overflow
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched...
CVE-2024-2852: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC15 15.03.20multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated...
CVE-2024-2850: Stack-based Buffer Overflow
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely...
PT-2024-2420
Name of the Vulnerable Software and Affected Versions Tenda AC15 version 15.03.05.18 Description A critical issue affects the saveParentControlInfo function of the file /goform/saveParentControlInfo, leading to a stack-based buffer overflow when the urls argument is manipulated. This can be...
CVE-2024-1848
Heap-based Buffer Overflow, Memory Corruption, Out-Of-Bounds Read, Out-Of-Bounds Write, Stack-based Buffer Overflow, Type Confusion, Uninitialized Variable, Use-After-Free vulnerabilities exist in the file reading procedure in SOLIDWORKS Desktop on Release SOLIDWORKS 2024. These vulnerabilities...
CVE-2024-2815
CVE-2024-2815 affects Tenda AC15, specifically the R7WebsSecurityHandler in /goform/execCommand. The vulnerability stems from a stack-based buffer overflow caused by manipulating the password argument, enabling remote exploitation. Public exploit information is indicated in the entry. Connected s...
CVE-2024-2813
A vulnerability was found in Tenda AC15 15.03.20multi. It has been declared as critical. This vulnerability affects the function formfastsettingwifiset of the file /goform/fastsettingwifiset. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated...