Lucene search
+L

23374 matches found

Vulnrichment
Vulnrichment
•added 2024/04/27 11:31 a.m.•39 views

CVE-2024-4249 Tenda i21 wifiSSIDget formwrlSSIDget stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS8.6AI score0.01349EPSS
SaveExploits0References4
CVE
CVE
•added 2024/04/27 11:31 a.m.•80 views

CVE-2024-4249

The CVE-2024-4249 entry affects Tenda i21 firmware 1.0.0.14(4656). The vulnerable component is the function formwrlSSIDget in the file /goform/wifiSSIDget, where manipulating the argument ssidIndex causes a stack-based buffer overflow. The vulnerability can be exploited remotely, and public explo...

9CVSS8.6AI score0.01349EPSS
SaveExploits0References4Affected Software1
NVD
NVD
•added 2024/04/27 11:15 a.m.•45 views

CVE-2024-4248

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. This issue affects the function formQosManageuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability...

9CVSS8.9AI score0.01349EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2024/04/27 10:31 a.m.•23 views

CVE-2024-4248 Tenda i21 formQosManage_user stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. This issue affects the function formQosManageuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability...

9CVSS8.6AI score0.01349EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2024/04/27 10:31 a.m.•51 views

CVE-2024-4248 Tenda i21 formQosManage_user stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. This issue affects the function formQosManageuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability...

9CVSS9AI score0.01349EPSS
SaveExploits0References4
NVD
NVD
•added 2024/04/27 10:15 a.m.•28 views

CVE-2024-4247

A vulnerability has been found in Tenda i21 1.0.0.144656 and classified as critical. This vulnerability affects the function formQosManageauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier...

9CVSS8.8AI score0.01453EPSS
SaveExploits0References4
CVE
CVE
•added 2024/04/27 9:31 a.m.•93 views

CVE-2024-4247

CVE-2024-4247 affects Tenda i21 (firmware 1.0.0.14(4656)). The vulnerability is in the formQosManage_auto function; manipulating the ssidIndex parameter triggers a stack-based buffer overflow. Exploitation is described as remote. Connected advisories reiterate the same details and point to VDB-26...

9CVSS8.5AI score0.01453EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
•added 2024/04/27 9:31 a.m.•37 views

CVE-2024-4247 Tenda i21 formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.144656 and classified as critical. This vulnerability affects the function formQosManageauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier...

9CVSS9AI score0.01453EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2024/04/27 9:31 a.m.•25 views

CVE-2024-4247 Tenda i21 formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.144656 and classified as critical. This vulnerability affects the function formQosManageauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier...

9CVSS8.5AI score0.01453EPSS
SaveExploits0References4
NVD
NVD
•added 2024/04/27 9:15 a.m.•29 views

CVE-2024-4246

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.144656. This affects the function formQosManageDoubleauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was...

9CVSS8.9AI score0.01349EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2024/04/27 8:31 a.m.•26 views

CVE-2024-4246 Tenda i21 formQosManageDouble_auto stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.144656. This affects the function formQosManageDoubleauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was...

9CVSS8.6AI score0.01349EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2024/04/27 8:31 a.m.•42 views

CVE-2024-4246 Tenda i21 formQosManageDouble_auto stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.144656. This affects the function formQosManageDoubleauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was...

9CVSS9AI score0.01349EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2024/04/27 7:31 a.m.•22 views

CVE-2024-4245 Tenda i21 formQosManageDouble_user stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.144656. Affected by this issue is the function formQosManageDoubleuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this...

9CVSS8.6AI score0.01349EPSS
SaveExploits0References4
CVE
CVE
•added 2024/04/27 7:31 a.m.•81 views

CVE-2024-4245

CVE-2024-4245 concerns a vulnerability in Tenda i21 1.0.0.14(4656) where the function formQosManageDouble_user is affected. The issue arises from improper handling of the argument ssidIndex , which leads to a stack-based buffer overflow. The vulnerability is described as allowing remote exploitat...

9CVSS8.6AI score0.01349EPSS
SaveExploits0References4Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•6 views

CVE-2024-4291: Stack-based Buffer Overflow

A vulnerability was found in Tenda A301 15.13.08.12multiTDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated...

9CVSS8.8AI score0.01453EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•9 views

CVE-2024-4251: Stack-based Buffer Overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buff...

9CVSS8.8AI score0.01349EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•9 views

CVE-2024-4249: Stack-based Buffer Overflow

A vulnerability was found in Tenda i21 1.0.0.144656. It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS8.7AI score0.01349EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•7 views

CVE-2024-4248: Stack-based Buffer Overflow

A vulnerability was found in Tenda i21 1.0.0.144656 and classified as critical. This issue affects the function formQosManageuser. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability...

9CVSS8.7AI score0.01349EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•7 views

CVE-2024-4247: Stack-based Buffer Overflow

A vulnerability has been found in Tenda i21 1.0.0.144656 and classified as critical. This vulnerability affects the function formQosManageauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier...

9CVSS8.6AI score0.01453EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/27 12:00 a.m.•7 views

CVE-2024-4246: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.144656. This affects the function formQosManageDoubleauto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was...

9CVSS8.7AI score0.01349EPSS
SaveExploits0References3
Rows per page
Query Builder