Lucene search
+L

2147 matches found

Vulnrichment
Vulnrichment
added 2024/04/24 2:0 p.m.15 views

CVE-2024-4111 Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been...

9CVSS6.9AI score0.01453EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
added 2024/04/23 9:0 p.m.22 views

CVE-2024-4066 Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow

A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is...

9CVSS7AI score0.01757EPSS
SaveExploits1References4
Cvelist
Cvelist
added 2024/04/23 9:0 p.m.27 views

CVE-2024-4066 Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow

A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is...

9CVSS9AI score0.01757EPSS
SaveExploits1References4
Cvelist
Cvelist
added 2024/04/23 8:0 p.m.34 views

CVE-2024-4065 Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...

9CVSS9AI score0.01643EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
added 2024/04/23 8:0 p.m.18 views

CVE-2024-4065 Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...

9CVSS7.1AI score0.01643EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
added 2024/04/23 8:0 p.m.17 views

CVE-2024-4064 Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely...

9CVSS7.2AI score0.01757EPSS
SaveExploits1References4
CVE
CVE
added 2024/04/23 12:0 a.m.74 views

CVE-2024-33211

CVE-2024-33211 : The Tenda FH1206 device (V1.2.0.8(8155)_EN) has a stack-based buffer overflow via the PPPOEPassword parameter in ip/goform/QuickIndex. Root cause: unchecked input length leading to stack overflow. Affected component is the QuickIndex handling; CVSS 3.1 vector indicates network at...

7.3CVSS7.7AI score0.00434EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2024/04/23 12:0 a.m.79 views

CVE-2024-33215

CVE-2024-33215 affects the Tenda FH1206 router (V1.2.0.8(8155)_EN). The vulnerability is a stack-based buffer overflow via the mitInterface parameter in the function path ip/goform/addressNat . Root cause: likely insufficient input length validation on mitInterface. Impact, per CVSS: High confide...

9.8CVSS7.7AI score0.00701EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
added 2024/04/17 10:53 p.m.31 views

CVE-2023-4234 Ofono: sms decoder stack-based buffer overflow remote code execution vulnerability within the decode_submit_report() function

A flaw was found in ofono, an Open Source Telephony on Linux. A stack overflow bug is triggered within the decodesubmitreport function during the SMS decoding. It is assumed that the attack scenario is accessible from a compromised modem, a malicious base station, or just SMS. There is a bound...

8.1CVSS8.3AI score0.01149EPSS
SaveExploits1References1
Vulnrichment
Vulnrichment
added 2024/04/17 12:0 p.m.12 views

CVE-2024-3910 Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.91307. Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched...

9CVSS7AI score0.0173EPSS
SaveExploits1References4
Cvelist
Cvelist
added 2024/04/17 12:0 p.m.27 views

CVE-2024-3910 Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.91307. Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched...

9CVSS8.9AI score0.0173EPSS
SaveExploits1References4
Cvelist
Cvelist
added 2024/04/17 11:31 a.m.20 views

CVE-2024-3909 Tenda AC500 execCommand formexeCommand stack-based overflow

A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...

9CVSS9AI score0.01676EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
added 2024/04/17 11:31 a.m.15 views

CVE-2024-3909 Tenda AC500 execCommand formexeCommand stack-based overflow

A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...

9CVSS7AI score0.01676EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
added 2024/04/17 11:0 a.m.15 views

CVE-2024-3907 Tenda AC500 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.91307. It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...

9CVSS7AI score0.01906EPSS
SaveExploits1References4
Cvelist
Cvelist
added 2024/04/17 11:0 a.m.28 views

CVE-2024-3907 Tenda AC500 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.91307. It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...

9CVSS9AI score0.01906EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
added 2024/04/17 10:31 a.m.13 views

CVE-2024-3906 Tenda AC500 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.91307. It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely...

9CVSS6.9AI score0.01658EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
added 2024/04/17 10:31 a.m.13 views

CVE-2024-3905 Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.91307. It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely...

9CVSS7.1AI score0.01773EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
added 2024/04/16 8:0 p.m.13 views

CVE-2024-3882 Tenda W30E fromRouteStatic stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25633. It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS7AI score0.01447EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
added 2024/04/16 7:31 p.m.14 views

CVE-2024-3881 Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25633 and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...

9CVSS7AI score0.01459EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2024/04/16 7:31 p.m.34 views

CVE-2024-3881 Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25633 and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...

9CVSS9AI score0.01459EPSS
SaveExploits0References4
Rows per page
Query Builder