9 matches found
Security Bulletin: Multiple security vulnerabilities in IBM Business Automation Manager Open Editions
Summary In addition to many updates of operating system level packages, the following security vulnerabilities are addressed in IBM Business Automation Manager Open Editions 8.0.9 Vulnerability Details CVEID:CVE-2017-9096 DESCRIPTION: The XML parsers in iText before 5.5.12 and 7.x before 7.0.3 do...
CVE-2025-59103
The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users...
EUVD-2025-206370
The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users...
CVE-2025-59103 Weak Default Passwords for SSH Access in dormakaba access manager
The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users...
CVE-2025-59103
The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users...
CVE-2025-53963
CVE-2025-53963 affects Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. An SSH server on port 22 uses a weak default root password (ionadmin) with no enforced password-change policy, allowing a network-connected attacker to achieve root code execution. Notes across sources indicate the vu...
CVE-2025-49599
Huawei EG8141A5 devices through V5R019C00S100, EG8145V5 devices through V5R019C00S100, and EG8145V5-V2 devices through V5R021C00S184 allow the Epuser account to disable ONT firewall functionality, e.g., to remove the default blocking of the SSH and TELNET TCP ports, aka HWNO-56Q3...
CVE-2019-15017
The SSH service is enabled on the Zingbox Inspector versions 1.294 and earlier, exposing SSH to the local network. When combined with PAN-SA-2019-0027, this can allow an attacker to authenticate to the service using hardcoded credentials...
CVE-2017-17877
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local development, the device is publicly available via IPv6 TCP port 22 over the internet with stateless address autoconfiguration by default, which makes it easier for remote attackers to obtain access by...