Lucene search
+L

966 matches found

CVE
CVE
added 2026/01/15 8:20 p.m.67 views

CVE-2026-21906

CVE-2026-21906 overview (Junos OS SRX Series) A vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS on SRX Series can be triggered by a specific ICMP packet routed through a GRE tunnel when PowerMode IPsec (PMI) and GRE performance acceleration are enabled. An unauthe...

8.7CVSS6.7AI score0.00517EPSS
SaveExploits0References3Affected Software1
EUVD
EUVD
added 2026/01/15 8:19 p.m.14 views

EUVD-2026-2687

A Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability in the SIP application layer gateway ALG of Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC allows an unauthenticated network-based attacker sending specific SIP messages over TCP to crash the flow...

8.7CVSS6.5AI score0.0039EPSS
SaveExploits0References3
ATTACKERKB
ATTACKERKB
added 2026/01/15 8:19 p.m.5 views

CVE-2026-21905

A Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability in the SIP application layer gateway ALG of Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC allows an unauthenticated network-based attacker sending specific SIP messages over TCP to crash the flow...

8.7CVSS5.5AI score0.0039EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2026/01/15 8:19 p.m.71 views

CVE-2026-21905

CVE-2026-21905 affects Juniper Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC. The vulnerability is a loop with an unreachable exit condition in the SIP application layer gateway (ALG) that can be triggered by processing multiple SIP messages over TCP. This causes the flow management...

8.7CVSS6.6AI score0.0039EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2026/01/15 8:16 p.m.52 views

CVE-2025-60007 Junos OS: A specifically crafted 'show chassis' command causes chassisd to crash

A NULL Pointer Dereference vulnerability in the chassis daemon chassisd of Juniper Networks Junos OS on MX, SRX and EX Series allows a local attacker with low privileges to cause a Denial-of-Service DoS. When a user executes the 'show chassis' command with specifically crafted options, chassisd...

6.8CVSS0.00138EPSS
SaveExploits0References2
CVE
CVE
added 2026/01/15 8:16 p.m.39 views

CVE-2025-60007

The CVE-2025-60007 entry describes a NULL pointer dereference in Juniper Networks Junos OS chassisd (chassis daemon) on MX, SRX, and EX Series. A local attacker with low privileges can crash chassisd by issuing a crafted show chassis command, causing the affected components (except the Routing En...

6.8CVSS5.8AI score0.00138EPSS
SaveExploits0References2Affected Software1
EUVD
EUVD
added 2026/01/15 8:16 p.m.13 views

EUVD-2026-2703

A NULL Pointer Dereference vulnerability in the chassis daemon chassisd of Juniper Networks Junos OS on MX, SRX and EX Series allows a local attacker with low privileges to cause a Denial-of-Service DoS. When a user executes the 'show chassis' command with specifically crafted options, chassisd...

6.8CVSS6AI score0.00138EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2026/01/15 12:00 a.m.13 views

PT-2026-3130

Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS versions prior to 22.4R3-S7 Juniper Networks Junos OS versions 23.2 before 23.2R2-S3 Juniper Networks Junos OS versions 23.4 before 23.4R2-S4 Juniper Networks Junos OS versions 24.2 before 24.2R2 Description A Double...

8.7CVSS6.6AI score0.0039EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2026/01/15 12:00 a.m.20 views

PT-2026-3129

Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS on SRX Series versions 23.2R2-S2 through 23.2R2-S4 Juniper Networks Junos OS on SRX Series versions 23.4R2-S1 through 23.4R2-S4 Juniper Networks Junos OS on SRX Series versions prior to 24.2R2-S2 Juniper Networks Juno...

8.7CVSS6.6AI score0.0039EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2026/01/15 12:00 a.m.30 views

PT-2026-3119

Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC versions prior to 21.2R3-S10 Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC versions 21.4 through 21.4R3-S12 Juniper Networks Junos OS o...

8.7CVSS6.6AI score0.0039EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2026/01/15 12:00 a.m.15 views

PT-2026-3120

Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS on SRX Series versions prior to 21.4R3-S12 Juniper Networks Junos OS on SRX Series versions 22.4 before 22.4R3-S8 Juniper Networks Junos OS on SRX Series versions 23.2 before 23.2R2-S5 Juniper Networks Junos OS on SRX...

8.7CVSS6.7AI score0.00517EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2026/01/14 12:00 a.m.6 views

Juniper Junos OS Vulnerability (JSA106018)

The version of Junos OS installed on the remote host is affected by a vulnerability as referenced in the JSA106018 advisory. - A Double Free vulnerability in the flow processing daemon flowd of Juniper Networks Junos OS on SRX and MX Series allows an unauthenticated, network-based attacker to cau...

8.7CVSS5.8AI score0.0039EPSS
SaveExploits0References2
RedhatCVE
RedhatCVE
added 2025/10/10 4:20 p.m.16 views

CVE-2025-52960

A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific SIP...

8.2CVSS6.8AI score0.00309EPSS
SaveExploits0References1
EUVD
EUVD
added 2025/10/09 6:30 p.m.12 views

EUVD-2025-33402

A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...

8.2CVSS6.4AI score0.00309EPSS
SaveExploits0References2
OSV
OSV
added 2025/10/09 4:15 p.m.12 views

CVE-2025-59968

A Missing Authorization vulnerability in the Juniper Networks Junos Space Security Director allows an unauthenticated network-based attacker to read or modify metadata via the web interface. Tampering with this metadata can result in managed SRX Series devices permitting network traffic that...

7.7CVSS5.8AI score0.00284EPSS
SaveExploits0References2
OSV
OSV
added 2025/10/09 4:15 p.m.24 views

CVE-2025-52960

A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...

8.2CVSS5.8AI score0.00309EPSS
SaveExploits0References2
NVD
NVD
added 2025/10/09 4:15 p.m.39 views

CVE-2025-52960

A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...

8.2CVSS0.00309EPSS
SaveExploits0References2
OSV
OSV
added 2025/10/09 4:15 p.m.22 views

CVE-2025-11198

A Missing Authentication for Critical Function vulnerability in Juniper Networks Security Director Policy Enforcer allows an unauthenticated, network-based attacker to replace legitimate vSRX images with malicious ones. If a trusted user initiates deployment, Security Director Policy Enforcer wil...

8.5CVSS5.8AI score0.00255EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/10/09 3:48 p.m.7 views

CVE-2025-59968 Junos Space Security Director: Insufficient authorization for sensitive resources in web interface

A Missing Authorization vulnerability in the Juniper Networks Junos Space Security Director allows an unauthenticated network-based attacker to read or modify metadata via the web interface. Tampering with this metadata can result in managed SRX Series devices permitting network traffic that...

8.6CVSS6.5AI score0.00284EPSS
SaveExploits0References2
CVE
CVE
added 2025/10/09 3:40 p.m.60 views

CVE-2025-52960

CVE-2025-52960 affects Juniper Networks Junos OS on SRX Series and MX Series, caused by a Buffer Copy without Checking Size in the SIP ALG (flowd/mspmand). The underlying issue occurs when memory utilization is high and specific SIP packets arrive, crashing the flowd process and causing a DoS; th...

8.2CVSS6.2AI score0.00309EPSS
SaveExploits0References2Affected Software1
Rows per page
Query Builder