966 matches found
CVE-2026-21906
CVE-2026-21906 overview (Junos OS SRX Series) A vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS on SRX Series can be triggered by a specific ICMP packet routed through a GRE tunnel when PowerMode IPsec (PMI) and GRE performance acceleration are enabled. An unauthe...
EUVD-2026-2687
A Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability in the SIP application layer gateway ALG of Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC allows an unauthenticated network-based attacker sending specific SIP messages over TCP to crash the flow...
CVE-2026-21905
A Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability in the SIP application layer gateway ALG of Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC allows an unauthenticated network-based attacker sending specific SIP messages over TCP to crash the flow...
CVE-2026-21905
CVE-2026-21905 affects Juniper Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC. The vulnerability is a loop with an unreachable exit condition in the SIP application layer gateway (ALG) that can be triggered by processing multiple SIP messages over TCP. This causes the flow management...
CVE-2025-60007 Junos OS: A specifically crafted 'show chassis' command causes chassisd to crash
A NULL Pointer Dereference vulnerability in the chassis daemon chassisd of Juniper Networks Junos OS on MX, SRX and EX Series allows a local attacker with low privileges to cause a Denial-of-Service DoS. When a user executes the 'show chassis' command with specifically crafted options, chassisd...
CVE-2025-60007
The CVE-2025-60007 entry describes a NULL pointer dereference in Juniper Networks Junos OS chassisd (chassis daemon) on MX, SRX, and EX Series. A local attacker with low privileges can crash chassisd by issuing a crafted show chassis command, causing the affected components (except the Routing En...
EUVD-2026-2703
A NULL Pointer Dereference vulnerability in the chassis daemon chassisd of Juniper Networks Junos OS on MX, SRX and EX Series allows a local attacker with low privileges to cause a Denial-of-Service DoS. When a user executes the 'show chassis' command with specifically crafted options, chassisd...
PT-2026-3130
Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS versions prior to 22.4R3-S7 Juniper Networks Junos OS versions 23.2 before 23.2R2-S3 Juniper Networks Junos OS versions 23.4 before 23.4R2-S4 Juniper Networks Junos OS versions 24.2 before 24.2R2 Description A Double...
PT-2026-3129
Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS on SRX Series versions 23.2R2-S2 through 23.2R2-S4 Juniper Networks Junos OS on SRX Series versions 23.4R2-S1 through 23.4R2-S4 Juniper Networks Junos OS on SRX Series versions prior to 24.2R2-S2 Juniper Networks Juno...
PT-2026-3119
Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC versions prior to 21.2R3-S10 Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC versions 21.4 through 21.4R3-S12 Juniper Networks Junos OS o...
PT-2026-3120
Name of the Vulnerable Software and Affected Versions Juniper Networks Junos OS on SRX Series versions prior to 21.4R3-S12 Juniper Networks Junos OS on SRX Series versions 22.4 before 22.4R3-S8 Juniper Networks Junos OS on SRX Series versions 23.2 before 23.2R2-S5 Juniper Networks Junos OS on SRX...
Juniper Junos OS Vulnerability (JSA106018)
The version of Junos OS installed on the remote host is affected by a vulnerability as referenced in the JSA106018 advisory. - A Double Free vulnerability in the flow processing daemon flowd of Juniper Networks Junos OS on SRX and MX Series allows an unauthenticated, network-based attacker to cau...
CVE-2025-52960
A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific SIP...
EUVD-2025-33402
A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...
CVE-2025-59968
A Missing Authorization vulnerability in the Juniper Networks Junos Space Security Director allows an unauthenticated network-based attacker to read or modify metadata via the web interface. Tampering with this metadata can result in managed SRX Series devices permitting network traffic that...
CVE-2025-52960
A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...
CVE-2025-52960
A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...
CVE-2025-11198
A Missing Authentication for Critical Function vulnerability in Juniper Networks Security Director Policy Enforcer allows an unauthenticated, network-based attacker to replace legitimate vSRX images with malicious ones. If a trusted user initiates deployment, Security Director Policy Enforcer wil...
CVE-2025-59968 Junos Space Security Director: Insufficient authorization for sensitive resources in web interface
A Missing Authorization vulnerability in the Juniper Networks Junos Space Security Director allows an unauthenticated network-based attacker to read or modify metadata via the web interface. Tampering with this metadata can result in managed SRX Series devices permitting network traffic that...
CVE-2025-52960
CVE-2025-52960 affects Juniper Networks Junos OS on SRX Series and MX Series, caused by a Buffer Copy without Checking Size in the SIP ALG (flowd/mspmand). The underlying issue occurs when memory utilization is high and specific SIP packets arrive, crashing the flowd process and causing a DoS; th...