Lucene search
+L

115 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/14 12:00 a.m.•11 views

CVE-2020-25152: Session Fixation

A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges...

8.1CVSS7.5AI score0.01281EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/14 12:00 a.m.•13 views

CVE-2020-25150: Relative Path Traversal

A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute...

9CVSS8AI score0.01529EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/14 12:00 a.m.•10 views

CVE-2020-25154: URL Redirection to Untrusted Site

An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites...

6.1CVSS6.3AI score0.00663EPSS
SaveExploits0References2
osv_cve
osv_cve
•added 2021/08/25 12:15 p.m.•24 views

CVE-2021-33883

A Cleartext Transmission of Sensitive Information vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to obtain sensitive information by snooping on the network traffic. The exposed data includes critical values for a pump's internal configuration...

7.5CVSS5.9AI score0.00832EPSS
SaveExploits1References2
The Hacker News
The Hacker News
•added 2021/08/25 10:28 a.m.•67 views

B. Braun Infusomat Pumps Could Let Attackers Remotely Alter Medication Dosages

Cybersecurity researchers have disclosed five previously unreported security vulnerabilities affecting B. Braun's Infusomat Space Large Volume Pump and SpaceStation that could be abused by malicious parties to tamper with medication doses without any prior authentication. McAfee, which discovered...

10CVSS0.4AI score0.0558EPSS
SaveExploits4
CNNVD
CNNVD
•added 2021/08/25 12:00 a.m.•26 views

B.Braun SpaceCom2 code-related vulnerabilities

The B. Braun SpaceCom2 is a hardware device from B. Braun, Germany, designed to connect to external devices to record data in a patient data management system, PC, or USB memory stick. A security vulnerability exists in versions of the B. Braun SpaceCom2 prior to 012U000062, which allows a remote...

9.1CVSS8.6AI score0.00984EPSS
SaveExploits1References6
Positive Technologies
Positive Technologies
•added 2020/10/22 12:00 a.m.•11 views

PT-2020-6692

Name of the Vulnerable Software and Affected Versions B. Braun Melsungen AG SpaceCom versions L81/U61 and earlier B. Braun Melsungen AG Data module compactplus versions A10 and A11 Description The issue is related to the configuration import mechanism, which allows attackers with command line...

7.2CVSS0.00249EPSS
SaveExploits0References6
Prion
Prion
•added 2017/06/30 3:29 a.m.•29 views

Open redirect

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module integrated as part number 8713142U, software versions prior to Version 012U000040, and SpaceStation part number 8713140U with...

5.8CVSS6.1AI score0.00954EPSS
SaveExploits0References1
NVD
NVD
•added 2017/06/30 3:29 a.m.•40 views

CVE-2017-6018

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module integrated as part number 8713142U, software versions prior to Version 012U000040, and SpaceStation part number 8713140U with...

6.1CVSS6.2AI score0.00954EPSS
SaveExploits0References1
CVE
CVE
•added 2017/06/30 2:35 a.m.•71 views

CVE-2017-6018

Summary : CVE-2017-6018 describes an open redirect in B. Braun Medical’s SpaceCom module, used with SpaceStation docking stations. Affected products/versions : SpaceCom module integrated in SpaceStation (part 8713142U) and SpaceStation with SpaceCom module (part 8713160U), both with software vers...

6.1CVSS6.2AI score0.00954EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2017/06/30 2:35 a.m.•49 views

CVE-2017-6018

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module integrated as part number 8713142U, software versions prior to Version 012U000040, and SpaceStation part number 8713140U with...

6.2AI score0.00954EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2017/06/30 12:00 a.m.•10 views

PT-2017-16835

Name of the Vulnerable Software and Affected Versions B. Braun Medical SpaceStation with SpaceCom module versions prior to 012U000040 B. Braun Medical SpaceStation versions prior to 012U000040 with installed SpaceCom module Description An open redirect issue was discovered in the B. Braun Medical...

6.1CVSS0.00954EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/06/30 12:00 a.m.•13 views

CVE-2017-6018: URL Redirection to Untrusted Site

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module integrated as part number 8713142U, software versions prior to Version 012U000040, and SpaceStation part number 8713140U with...

6.1CVSS6.3AI score0.00954EPSS
SaveExploits0References2
CNVD
CNVD
•added 2017/05/24 12:00 a.m.•16 views

B. Braun SpaceCom Module Open Redirect Vulnerability

The B. Braun SpaceCom Module is a product designed to facilitate the exchange of information in healthcare systems by connecting hospital network systems to external clinical systems, entering data, medical history, service information, etc. to connected workstations. B. An open redirection...

6.1CVSS6.6AI score0.00954EPSS
SaveExploits0References1
ICS
ICS
•added 2017/03/23 12:00 a.m.•71 views

ICSMA-17-082-02_B. Braun Medical SpaceCom Open Redirect Vulnerability

OVERVIEW This advisory was originally posted to the NCCIC Portal on March 23, 2017, and is being released to the ICS-CERT web site. Marc Ruef and Rocco Gagliardi of scip AG have identified an open redirect vulnerability in B. Braun Medical’s SpaceCom module, which is integrated into the...

6.1CVSS6.4AI score0.00954EPSS
SaveExploits0References2
Rows per page