Lucene search
+L

242 matches found

OSV
OSV
added 2025/08/14 6:52 p.m.3 views

MAL-2025-29394 Malicious code in playwright-mutation-mysql-solis (npm)

The package playwright-mutation-mysql-solis was found to contain malicious code...

7.2AI score
SaveExploits0
Openbugbounty
Openbugbounty
added 2022/02/14 10:35 a.m.11 views

solisgardenshoa.com Cross Site Scripting vulnerability OBB-2372077

Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...

6.2AI score
SaveExploits0
CNVD
CNVD
added 2020/05/11 12:0 a.m.5 views

GNUTeca Path Traversal Vulnerability

Solis Gnuteca is a library management system from Solis Brazil. The system includes features such as e-mail alerts, automated inventory, location tracking and user registration. A path traversal vulnerability exists in Solis GNUTeca version 3.8. The vulnerability stems from the failure of a...

5.3CVSS6.8AI score0.01323EPSS
SaveExploits1References1
CNVD
CNVD
added 2020/05/11 12:0 a.m.1 views

Solis Gnuteca SQL Injection Vulnerability

Solis Gnuteca is a library management system from Solis Brazil. The system includes features such as e-mail alerts, automated inventory, location tracking and user registration. A SQL injection vulnerability exists in Solis Gnuteca version 3.8. The vulnerability stems from a database-based...

9.8CVSS8.2AI score0.01034EPSS
SaveExploits0References1
OSV
OSV
added 2020/05/09 7:15 p.m.4 views

CVE-2020-12765

Solis Miolo 2.0 allows index.php?module=install&action=view&item= Directory Traversal...

5.3CVSS6.1AI score0.01299EPSS
SaveExploits0References1
NVD
NVD
added 2020/05/09 7:15 p.m.16 views

CVE-2020-12765

Solis Miolo 2.0 allows index.php?module=install&action=view&item= Directory Traversal...

5.3CVSS5.4AI score0.01299EPSS
SaveExploits0References1
Prion
Prion
added 2020/05/09 7:15 p.m.19 views

Directory traversal

Solis Miolo 2.0 allows index.php?module=install&action=view&item= Directory Traversal...

5CVSS5.4AI score0.01299EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/05/09 6:35 p.m.29 views

CVE-2020-12765

Solis Miolo 2.0 allows index.php?module=install&action=view&item= Directory Traversal...

5.4AI score0.01299EPSS
SaveExploits0References1
CVE
CVE
added 2020/05/09 6:35 p.m.104 views

CVE-2020-12765

CVE-2020-12765 affects Solis Miolo 2.0, with a Directory Traversal vulnerability exposed via index.php?module=install&action=view&item=. The connected Red Hat entry corroborates the Solis Miolo 2.0 context and the path traversal behavior, but the available documents do not specify the exact affec...

5.3CVSS5.3AI score0.01299EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2017/02/13 10:59 p.m.20 views

CVE-2016-8355

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and...

9.9CVSS9.5AI score0.01491EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2017/02/13 10:59 p.m.2 views

CVE-2016-8358

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between...

8.5CVSS5.5AI score0.005EPSS
SaveExploits0References3
ATTACKERKB
ATTACKERKB
added 2017/02/13 10:59 p.m.3 views

CVE-2016-8355

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and...

9.9CVSS5.8AI score0.01491EPSS
SaveExploits0References3
OSV
OSV
added 2017/02/13 10:59 p.m.5 views

CVE-2016-8358

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between...

8.5CVSS5.8AI score0.005EPSS
SaveExploits0References2
Prion
Prion
added 2017/02/13 10:59 p.m.13 views

Design/Logic Flaw

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between...

6CVSS7.1AI score0.005EPSS
SaveExploits0References2Affected Software1
NVD
NVD
added 2017/02/13 10:59 p.m.21 views

CVE-2016-8358

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between...

8.5CVSS9AI score0.005EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2017/02/13 10:0 p.m.28 views

CVE-2016-8358

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between...

8.5AI score0.005EPSS
SaveExploits0References2
CVE
CVE
added 2017/02/13 10:0 p.m.42 views

CVE-2016-8358

CVE-2016-8358 concerns Smiths Medical CADD-Solis Medication Safety Software (versions 1.0, 2.0, 3.0, 3.1). The root issue is that the software does not verify identities at communication endpoints, enabling a potential man-in-the-middle to access the communication channel between endpoints. The v...

8.5CVSS8.3AI score0.005EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2017/02/13 10:0 p.m.43 views

CVE-2016-8355

The CVE-2016-8355 entry documents an elevation-of-privilege flaw in Smiths-Medical CADD-Solis Medication Safety Software (versions 1.0–3.1). An authenticated user can gain elevated privileges on the embedded SQL database, enabling modification of drug libraries, user management (add/delete users)...

9.9CVSS9.2AI score0.01491EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2017/02/13 10:0 p.m.23 views

CVE-2016-8355

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and...

9.5AI score0.01491EPSS
SaveExploits0References2
CNVD
CNVD
added 2016/12/03 12:0 a.m.6 views

Smiths-Medical CADD-Solis Medication Safety Software Security Bypass Vulnerability

Smiths-Medical, headquartered in Plymouth, Minnesota, is a subsidiary of Smiths Group, a company based in the U.K. CADD-Solis drug safety software, is an application used to set dose limits for infusion pumps. A security bypass vulnerability exists in Smiths-Medical CADD-Solis Medication Safety...

8.5CVSS7.4AI score0.005EPSS
SaveExploits0References1
Rows per page
Query Builder