Lucene search
+L

610 matches found

NVD
NVD
added 2017/08/05 5:29 p.m.26 views

CVE-2017-9855

An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...

9.8CVSS9.6AI score0.01583EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.24 views

CVE-2017-9856

An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device...

9.8CVSS9.3AI score0.00664EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.32 views

CVE-2017-9862

An issue was discovered in SMA Solar Technology products. When signed into Sunny Explorer with a wrong password, it is possible to create a debug report, disclosing information regarding the application and allowing the attacker to create and save a .txt file with contents to his liking. An...

7.5CVSS7.4AI score0.01724EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.24 views

CVE-2017-9863

An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cross-site request forgery can be used to change settings in the inverters for example, issuing a POST request to change the user password. All Sunny Explorer...

8.8CVSS8.6AI score0.00696EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.21 views

CVE-2017-9860

An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the invert...

10CVSS9.2AI score0.02244EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.22 views

CVE-2017-9852

An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company but a...

9.8CVSS9.7AI score0.01716EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.28 views

CVE-2017-9859

An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This...

9.8CVSS9.4AI score0.01127EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.22 views

CVE-2017-9864

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis...

7.5CVSS7.5AI score0.01512EPSS
SaveExploits0References3
Prion
Prion
added 2017/08/05 5:29 p.m.22 views

Information disclosure

DISPUTED An issue was discovered in SMA Solar Technology products. When signed into Sunny Explorer with a wrong password, it is possible to create a debug report, disclosing information regarding the application and allowing the attacker to create and save a .txt file with contents to his liking...

5CVSS6.7AI score0.01724EPSS
SaveExploits0References3
Prion
Prion
added 2017/08/05 5:29 p.m.17 views

Design/Logic Flaw

DISPUTED An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analys...

5CVSS7AI score0.01512EPSS
SaveExploits0References3
Prion
Prion
added 2017/08/05 5:29 p.m.18 views

Authentication flaw

DISPUTED An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, et...

4.3CVSS7.2AI score0.00689EPSS
SaveExploits0References3
Prion
Prion
added 2017/08/05 5:29 p.m.23 views

Design/Logic Flaw

DISPUTED An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, t...

10CVSS7AI score0.02244EPSS
SaveExploits0References3
NVD
NVD
added 2017/08/05 5:29 p.m.19 views

CVE-2017-9858

An issue was discovered in SMA Solar Technology products. By sending crafted packets to an inverter and observing the response, active and inactive user accounts can be determined. This aids in further attacks such as a brute force attack as one now knows exactly which users exist and which do no...

7.5CVSS7.4AI score0.02058EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2017/08/05 5:00 p.m.26 views

CVE-2017-9857

An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, etc. can be...

8.2AI score0.00689EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2017/08/05 5:00 p.m.39 views

CVE-2017-9864

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis...

7.5AI score0.01512EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
added 2017/08/05 5:00 p.m.17 views

CVE-2017-9851

An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...

7.1AI score0.01865EPSS
SaveExploits0References3
CVE
CVE
added 2017/08/05 5:00 p.m.55 views

CVE-2017-9862

SMA Solar Technology Sunny Explorer information-disclosure (CVE-2017-9862) affects Sunny Boy TLST-21/TL-21 and Sunny Tripower TL-10/TL-30. When signing in with an incorrect password, a debug report can be created that exposes application information and allows saving a .txt file with arbitrary co...

7.5CVSS7.3AI score0.01724EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2017/08/05 5:00 p.m.34 views

CVE-2017-9859

An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This...

9.4AI score0.01127EPSS
SaveExploits0References3
CVE
CVE
added 2017/08/05 5:00 p.m.61 views

CVE-2017-9858

CVE-2017-9858 affects SMA Solar Technology inverters (Sunny Boy TLST-21, TL-21; Sunny Tripower TL-10, TL-30). By sending crafted packets to the inverter and observing responses, an attacker can determine which user accounts are active or inactive, enabling brute-force planning. The vendor notes t...

7.5CVSS7.4AI score0.02058EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2017/08/05 5:00 p.m.66 views

CVE-2017-9853

SMA Solar Technology inverters (Sunny Boy TLST-21/TL-21 and Sunny Tripower TL-10/TL-30) are affected by a weak password policy: no complexity or length requirements and a maximum 12-character limit, making strong passwords impossible. The CVE details state that this could allow password-related a...

9.8CVSS9.3AI score0.01716EPSS
SaveExploits0References3Affected Software1
Rows per page
Query Builder