53 matches found
PT-2021-20312 · Siemens · Simatic Cp 343-1 +6
Name of the Vulnerable Software and Affected Versions: SIMATIC CP 343-1 incl. SIPLUS variants All versions SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions SIMATIC CP 343-1 ERPC All versions SIMATIC CP 343-1 Lean incl. SIPLUS variants All versions SIMATIC CP 443-1 versions prior to V3...
CVE-2020-28391
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...
CVE-2020-25226
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The web server of the affected devices contains a vulnerability that may lead to a buffer overflow...
CVE-2020-15799
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...
Hardcoded credentials
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...
CVE-2020-25226
Siemens SCALANCE X products are affected by CVE-2020-25226: heap-based/buffer overflow in the devices’ web server. Affected: SCALANCE X-200 (incl. SIPLUS NET) below v5.2.5, SCALANCE X-200IRT below v5.5.0, and SCALANCE X-300 below v4.1.0 (X-300 also affected by CVE-2020-15800 per ICS advisory). Ex...
CVE-2020-15799
A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...
CVE-2020-28391
Summary: CVE-2020-28391 affects Siemens SCALANCE X switches (X-200, X-200IRT, X-200RNA; incl. SIPLUS NET variants). Root cause: after factory reset, devices normally generate a new unique key, but when used with C-PLUG they ship a hardcoded private RSA key, enabling a man-in-the-middle and decryp...
PT-2021-2204 · Siemens · C-Plug +2
Name of the Vulnerable Software and Affected Versions: SCALANCE X-200 switch family incl. SIPLUS NET variants versions prior to V5.2.5 SCALANCE X-200IRT switch family incl. SIPLUS NET variants versions prior to V5.5.0 SCALANCE X-200RNA switch family versions prior to V3.2.7 Description: A...
CVE-2019-10939
A vulnerability has been identified in TIM 3V-IE incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE Advanced incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE DNP3 incl. SIPLUS NET variants All versions V3.3, TIM 4R-IE incl. SIPLUS NET variants All versions V2.8, TIM 4R-IE DNP3 incl...
Code injection
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALAN...
CVE-2019-10939
The CVE-2019-10939 issue affects Siemens TIM 3V-IE, TIM 3V-IE Advanced, TIM 3V-IE DNP3, TIM 4R-IE, and TIM 4R-IE DNP3 (SIPLUS NET variants) with open debug port exposure under the condition that the device IP is 192.168.1.2. The root cause is an open debug port that can be accessed by a network-a...
CVE-2019-10939
A vulnerability has been identified in TIM 3V-IE incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE Advanced incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE DNP3 incl. SIPLUS NET variants All versions V3.3, TIM 4R-IE incl. SIPLUS NET variants All versions V2.8, TIM 4R-IE DNP3 incl...
CVE-2019-13933
A vulnerability has been identified in SCALANCE X204RNA HSR, SCALANCE X204RNA PRP, SCALANCE X204RNA EEC HSR, SCALANCE X204RNA EEC PRP, SCALANCE X204RNA EEC PRP/HSR, SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-...
Siemens SIPLUS NET CP443-1 Communications Adapter Detection
Binary data 750305.prm...
Siemens SIPLUS NET CP443-5 Extended Communications Adapter Detection
Binary data 750307.prm...
Siemens SIPLUS NET CSM 1277 Communications Adapter Detection
Binary data 750142.prm...
Siemens SIPLUS NET CP343-1 ADVANCED Communications Adapter Detection
Binary data 750270.prm...