Lucene search
K

13 matches found

BDU FSTEC
BDU FSTEC
added 2024/09/18 12:0 a.m.5 views

The vulnerability of the web servers of the microprogramming software for communication modules of SIMATIC CP, SIPLUS ET, and SIPLUS NET CP allows a perpetrator to cause service interruptions.

The vulnerability of the web servers of microprogramming software for communication modules of SIMATIC CP, SIPLUS ET, and SIPLUS NET CP is related to the use of memory after it is freed. Exploiting this vulnerability can allow a malicious actor to cause service failures remotely...

7.8CVSS7.1AI score0.00954EPSS
Exploits0References4Affected Software22
NVD
NVD
added 2024/02/13 9:15 a.m.32 views

CVE-2023-51440

A vulnerability has been identified in SIMATIC CP 343-1 6GK7343-1EX30-0XE0 All versions, SIMATIC CP 343-1 Lean 6GK7343-1CX10-0XE0 All versions, SIPLUS NET CP 343-1 6AG1343-1EX30-7XE0 All versions, SIPLUS NET CP 343-1 Lean 6AG1343-1CX10-2XE0 All versions. Affected products incorrectly validate TCP...

7.5CVSS7.5AI score0.00597EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2024/02/13 9:0 a.m.13 views

CVE-2023-51440

A vulnerability has been identified in SIMATIC CP 343-1 6GK7343-1EX30-0XE0 All versions, SIMATIC CP 343-1 Lean 6GK7343-1CX10-0XE0 All versions, SIPLUS NET CP 343-1 6AG1343-1EX30-7XE0 All versions, SIPLUS NET CP 343-1 Lean 6AG1343-1CX10-2XE0 All versions. Affected products incorrectly validate TCP...

7.5CVSS7AI score0.00597EPSS
Exploits0References1
BDU FSTEC
BDU FSTEC
added 2023/12/19 12:0 a.m.5 views

The vulnerability of the web server of the microprogramming software for communication modules of SIMATIC CP, SIPLUS NET CP 1543-1, and the servo drive system SINAMICS S210 allows a intruder to cause service interruptions.

The vulnerability of the web server of the microprogramming software for communication modules of SIMATIC CP, SIPLUS NET CP 1543-1, and the servo drive system SINAMICS S210 is related to the lack of a mechanism for releasing memory. Exploiting this vulnerability could allow an attacker, operating...

7.8CVSS7.2AI score0.00956EPSS
Exploits0References2
NVD
NVD
added 2021/09/14 11:15 a.m.21 views

CVE-2021-33737

A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 343-1 ERPC All versions, SIMATIC CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP...

7.8CVSS0.01022EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2021/09/14 12:0 a.m.5 views

PT-2021-20312 · Siemens · Simatic Cp 343-1 +6

Name of the Vulnerable Software and Affected Versions: SIMATIC CP 343-1 incl. SIPLUS variants All versions SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions SIMATIC CP 343-1 ERPC All versions SIMATIC CP 343-1 Lean incl. SIPLUS variants All versions SIMATIC CP 443-1 versions prior to V3...

7.8CVSS7.4AI score0.01022EPSS
Exploits0References2
Prion
Prion
added 2020/04/14 8:15 p.m.17 views

Code injection

A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALAN...

5CVSS7.4AI score0.01327EPSS
Exploits0References1Affected Software1
NVD
NVD
added 2016/11/18 9:59 p.m.21 views

CVE-2016-8562

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

7.5CVSS5.3AI score0.03624EPSS
Exploits0References5
Prion
Prion
added 2016/11/18 9:59 p.m.20 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Users with elevated privileges to TIA-Portal and project data on the engineering station could possibly get privileged access on affected devices...

6CVSS6.8AI score0.01585EPSS
Exploits0References4
Prion
Prion
added 2016/11/18 9:59 p.m.24 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

3.5CVSS6.8AI score0.03624EPSS
Exploits0References4
Cvelist
Cvelist
added 2016/11/18 9:0 p.m.34 views

CVE-2016-8562

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

5.1AI score0.03624EPSS
Exploits0References4
CVE
CVE
added 2016/11/18 9:0 p.m.1007 views

CVE-2016-8562

Siemens SIMATIC CP 1543-1 and SIPLUS NET CP 1543-1 (versions before 2.0.28) are affected by CVE-2016-8562. Under special conditions, SNMP variables on port 161/UDP, which should be read-only, can be written, potentially reducing availability or causing denial-of-service. The ICS advisory notes th...

7.5CVSS5.4AI score0.03624EPSS
In wildExploits0References5Affected Software1
ATTACKERKB
ATTACKERKB
added 2016/11/18 12:0 a.m.29 views

CVE-2016-8562

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

7.5CVSS6.1AI score0.03624EPSS
In wildExploits0References5