Lucene search
+L

4647 matches found

ICS
ICS
•added 2011/06/10 12:00 a.m.•16 views

Siemens SIMATIC S7-1200 CPU V1/V2 Devices

SUMMARY SIMATIC S7-1200 CPU V1/V2 controllers contain two vulnerabilities that could allow an unauthenticated remote attacker - to trigger functions by record and playback of legitimate network communication, or - to place the controller in stop/defect state by causing a communications error...

7.2AI score
SaveExploits0References10
ThreatPost
ThreatPost
•added 2011/05/23 4:53 p.m.•19 views

Metasploit Holding On Siemens Exploits

UPDATE: A week after a security researcher decided to cancel a technical discussion of security holes in industrial control software from Siemens, Inc., public exploits for the vulnerabilities are on hold while the company works to shore up systems running its Simatic programmable logic controlle...

7.5AI score
SaveExploits0References4
ThreatPost
ThreatPost
•added 2011/05/19 4:12 p.m.•15 views

SCADA Holes Allowed Remote Takedown of Siemens Systems

Security researcher Dillon Beresford decided not to present a talk at the TakedownCon in Dallas on Thursday, citing concerns about mayhem that could have resulted. But in an e-mail, he told Threatpost that the vulnerabilities could allow remote attackers to start or stop Siemens Programmable Logi...

0.5AI score
SaveExploits0References5
CVE
CVE
•added 2010/07/22 10:00 a.m.•440 views

CVE-2010-2772

CVE-2010-2772 affects Siemens SIMATIC WinCC and SIMATIC PCS 7: a security bypass via default hard-coded SQL credentials allows remote attackers to access the backend database with administrative-like access. The vulnerability is tied to use of default credentials in the WinCC SQL server, permitti...

7.8CVSS7.2AI score0.0055EPSS
SaveIn wildExploits2References14Affected Software1
attackerkb
attackerkb
•added 2010/07/22 12:00 a.m.•79 views

CVE-2010-2772

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. Recent assessments: Assessed Attacker...

9.3CVSS5.5AI score0.91324EPSS
SaveIn wildExploits16References15
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2010/07/22 12:00 a.m.•4 views

CVE-2010-2772: Use of Hard-coded Credentials

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...

7.8CVSS8.2AI score0.0055EPSS
SaveExploits2References2
Tenable Nessus
Tenable Nessus
•added 2006/12/11 12:00 a.m.•17 views

Siemens SIMATIC PDM Detection

Binary data scadaappsiemenspdmdetect.nbin...

7.3AI score
SaveExploits0
Rows per page