added 2017/07/07 5:29 p.m.13 views

CVE-2017-6868

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

8.1CVSS8.2AI score0.04174EPSS
SaveExploits0References4
Prion
Prion
added 2017/07/07 5:29 p.m.14 views

Authentication flaw

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

6.8CVSS8AI score0.04174EPSS
SaveExploits0References4Affected Software1
OSV
OSV
added 2017/07/07 5:29 p.m.6 views

CVE-2017-6868

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

8.1CVSS5.8AI score0.04174EPSS
SaveExploits0References4
CVE
CVE
added 2017/07/07 5:0 p.m.52 views

CVE-2017-6868

CVE-2017-6868 affects Siemens SIMATIC CP 44x-1 RNA modules (all versions before 1.4.1). An unauthenticated remote attacker who can reach Port 102/TCP and where the CP configuration file is stored on the RNA’s CPU may perform administrative actions on the CP through an improper authentication flaw...

8.1CVSS8AI score0.04174EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2017/07/07 5:0 p.m.24 views

CVE-2017-6868

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

8.1AI score0.04174EPSS
SaveExploits0References4
ThreatPost
ThreatPost
added 2017/06/23 2:7 p.m.13 views

Siemens Patches Two Vulnerabilities in SIMATIC CP and XHQ

Siemens patched two vulnerabilities in products commonly found in industrial control system setups this week. If exploited the flaws could allow an attacker to perform administrative actions or gain read access to sensitive data on affected systems. Siemens patched one issue .PDF on Tuesday and t...

0.8AI score
SaveExploits0References3
ICS
ICS
added 2017/06/22 12:0 a.m.35 views

Siemens SIMATIC CP 44x-1 Redundant Network Access Modules

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC CP 44x-1 Redundant Network Access RNA modules Vulnerability: Improper Authentication AFFECTED PRODUCTS The following versions of the SIMATIC CP 44x-1 RNA, which connect SIMATIC S7-400 CPUs t...

8.1CVSS8.8AI score0.04174EPSS
SaveExploits0References3
CNVD
CNVD
added 2017/06/21 12:0 a.m.6 views

Siemens SIMATIC CP 44x-1 RNA Module Unauthorized Operation Vulnerability

The Siemens SIMATIC CP 44x-1 RNA is a communication processor with integrated firewall, VPN, security protocols, data encryption, and other security features that provides network connectivity and secure communication for s7-1500 controllers. An unauthorized operation vulnerability exists in the...

8.1CVSS6.8AI score0.04174EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2017/05/19 12:0 a.m.81 views

Siemens SIMATIC WinCC (TIA Portal) 13 < 13 SP2 / 14 < 14 SP1 Multiple DoS

Binary data scadasiemenstiawincc13SP214SP1.nbin...

6.5CVSS6AI score0.00469EPSS
SaveExploits0References6
Prion
Prion
added 2017/05/11 10:29 a.m.20 views

Design/Logic Flaw

A vulnerability was discovered in Siemens SIMATIC WinCC V7.3 before Upd 11 and V7.4 before SP1, SIMATIC WinCC Runtime Professional V13 before SP2 and V14 before SP1, SIMATIC WinCC TIA Portal Professional V13 before SP2 and V14 before SP1 that could allow an authenticated, remote attacker who is...

4CVSS5AI score0.01923EPSS
SaveExploits0References3Affected Software3
NVD
NVD
added 2017/05/11 10:29 a.m.22 views

CVE-2017-6867

A vulnerability was discovered in Siemens SIMATIC WinCC V7.3 before Upd 11 and V7.4 before SP1, SIMATIC WinCC Runtime Professional V13 before SP2 and V14 before SP1, SIMATIC WinCC TIA Portal Professional V13 before SP2 and V14 before SP1 that could allow an authenticated, remote attacker who is...

4.9CVSS5.1AI score0.01923EPSS
SaveExploits0References3
Prion
Prion
added 2017/05/11 10:29 a.m.26 views

Design/Logic Flaw

Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI...

6.1CVSS6.1AI score0.00906EPSS
SaveExploits0References4Affected Software65
CVE
CVE
added 2017/05/11 10:0 a.m.62 views

CVE-2017-6867

CVE-2017-6867 affects Siemens SIMATIC WinCC family (WinCC v7.3 before Update 11, WinCC v7.4 before SP1; WinCC Runtime Professional v13 before SP2, v14 before SP1; WinCC (TIA Portal) Professional v13 before SP2, v14 before SP1). The issue is improper input validation allowing an authenticated remo...

4.9CVSS5.4AI score0.01923EPSS
SaveExploits0References3Affected Software3
CVE
CVE
added 2017/05/11 10:0 a.m.86 views

CVE-2017-6865

CVE-2017-6865 is a DoS vulnerability in Siemens PROFINET DCP handling affecting multiple Siemens products (WinCC, STEP 7/TIA Portal, PCS 7, WinAC/WinCC flexible, SCT, SINEMA, SINUMERIK, etc.). The root cause is improper input validation, where specially crafted PROFINET DCP broadcast packets on a...

6.5CVSS6AI score0.00469EPSS
SaveExploits0References2Affected Software16
CVE
CVE
added 2017/05/11 10:0 a.m.107 views

CVE-2017-2681

CVE-2017-2681 affects Siemens PROFINET DCP; specially crafted DCP packets on a local Layer-2 Ethernet can cause denial of service in affected devices. The issue primarily impacts SIMATIC HMI Multi Panels, HMI Mobile Panels, and S7-300/S7-400 families, plus a wide range of PROFINET-enabled product...

7.1CVSS6.1AI score0.00906EPSS
SaveExploits0References5Affected Software1
Cvelist
Cvelist
added 2017/05/11 10:0 a.m.31 views

CVE-2017-6865

A vulnerability has been identified in Primary Setup Tool PST All versions V4.2 HF1, SIMATIC Automation Tool All versions V3.0, SIMATIC NET PC-Software All versions V14 SP1, SIMATIC PCS 7 V8.1 All versions, SIMATIC PCS 7 V8.2 All versions V8.2 SP1, SIMATIC STEP 7 TIA Portal V13 All versions V13...

6.2AI score0.00469EPSS
SaveExploits0References2
ICS
ICS
added 2017/05/09 12:0 a.m.44 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update E)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

7.1CVSS0.3AI score0.01149EPSS
SaveExploits0References69
ICS
ICS
added 2017/05/09 12:0 a.m.36 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update H)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

7.1CVSS0.3AI score0.01149EPSS
SaveExploits0References75
ICS
ICS
added 2017/05/09 12:0 a.m.45 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update F)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

6.5CVSS0.1AI score0.00469EPSS
SaveExploits0References40
ICS
ICS
added 2017/05/09 12:0 a.m.111 views

Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional

CVSS v3 4.9 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC WinCC and SIMATIC WinCC Runtime Professional Vulnerability: Denial of Service AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following versions of SIMATIC WinCC, SIMATI...

4.9CVSS5.6AI score0.01923EPSS
SaveExploits0References3