Siemens SIMATIC S7-400 Input Validation Vulnerability
Siemens SIMATIC S7-400 is a programmable logic controller for manufacturing and process automation from Siemens, Germany. An input validation vulnerability exists in the Siemens SIMATIC S7-400 product, which can be exploited by an attacker to cause a service crash via a specially crafted packet...
Siemens SIMATIC STEP 7 Information Disclosure Vulnerability
Siemens SIMATIC STEP 7 TIA Portal is a suite of programming software for SIMATIC controllers from Siemens, Germany. The software provides PLC programming, design option packages and advanced drive technology. A security vulnerability exists in Siemens SIMATIC STEP 7 TIA Portal versions prior to...
Siemens SIMATIC S7-400 Input Validation Vulnerability
Siemens SIMATIC S7-400 is a programmable logic controller for manufacturing and process automation from Siemens, Germany. An input validation vulnerability exists in the Siemens SIMATIC S7-400. An attacker can exploit this vulnerability by sending specially crafted packets to TCP port 102 to caus...
Siemens SIMATIC HMI Device Detection (SNMP)
SNMP based detection of Siemens SIMATIC HMI devices. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...
Siemens SIMATIC HMI Device Detection Consolidation
Consolidation of Siemens SIMATIC HMI device detections. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...
Siemens SIMATIC HMI Device Detection (HTTP)
HTTP based detection of Siemens SIMATIC HMI devices. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...
Siemens SIMATIC S7 (Update A)
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC S7 Vulnerability: Resource Exhaustion 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-317-05 Siemens SIMATIC S7 that...
ICSA-18-317-06 Siemens SIMATIC STEP 7 (TIA Portal)
1. EXECUTIVE SUMMARY CVSS v3 4.0 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: SIMATIC STEP 7 TIA Portal Vulnerability: Unprotected Storage of Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to reconstruct passwords. 3...
PT-2018-2567 · Siemens · Simatic S7-400 Cpu 414-3 Dp +13
Name of the Vulnerable Software and Affected Versions: SIMATIC S7-400 CPU 412-1 DP V7 versions prior to V7.0.3 SIMATIC S7-400 CPU 412-2 DP V7 versions prior to V7.0.3 SIMATIC S7-400 CPU 412-2 PN V7 versions prior to V7.0.3 SIMATIC S7-400 CPU 414-2 DP V7 versions prior to V7.0.3 SIMATIC S7-400 CPU...
PT-2018-2566 · Siemens · Simatic S7-400 Cpu 416-2 Dp V7 +14
Name of the Vulnerable Software and Affected Versions: SIMATIC S7-400 CPU 412-1 DP V7 All versions SIMATIC S7-400 CPU 412-2 DP V7 All versions SIMATIC S7-400 CPU 412-2 PN V7 All versions V7.0.3 SIMATIC S7-400 CPU 414-2 DP V7 All versions SIMATIC S7-400 CPU 414-3 DP V7 All versions SIMATIC S7-400...
Siemens SIMATIC Panels
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC Panels Vulnerabilities: Path Traversal, Open Redirect 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow download of arbitrary files from the...
ICSA-18-317-07 Siemens SIMATIC IT Production Suite
1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SIMATIC IT Production Suite Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to compromise confidentiality, integrity and...
Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal)
1. EXECUTIVE SUMMARY CVSS v3 4.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC Panels and SIMATIC WinCC TIA Portal Vulnerability: Code Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker with network...
CVE-2018-13805
A vulnerability has been identified in SIMATIC ET 200SP Open Controller All versions = V2.0 and = V2.0 and = V2.0 and V2.5. An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to...
CVE-2018-13805
A vulnerability has been identified in SIMATIC ET 200SP Open Controller All versions = V2.0 and = V2.0 and = V2.0 and V2.5. An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to...
CVE-2018-13800
A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 All versions V4.2.3. The web interface could allow a Cross-Site Request Forgery CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a...
CVE-2018-13800
A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 All versions V4.2.3. The web interface could allow a Cross-Site Request Forgery CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a...
Design/Logic Flaw
A vulnerability has been identified in SIMATIC ET 200SP Open Controller All versions = V2.0 and = V2.0 and = V2.0 and V2.5. An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to...
Cross site request forgery (csrf)
A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 All versions V4.2.3. The web interface could allow a Cross-Site Request Forgery CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a...
CVE-2018-13800
A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 All versions V4.2.3. The web interface could allow a Cross-Site Request Forgery CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a...