Lucene search
+L

4843 matches found

NCSC
NCSC
•added 2021/07/13 12:00 a.m.•27 views

Vulnerabilities fixed in Siemens SIMATIC

Siemens has fixed vulnerabilities in Simatic products. The vulnerabilities potentially enable a malicious person to launch attacks execute attacks that result in the following categories of damage: Denial-of-Service DoS Manipulation of data Circumvention of security measure Remote code execution...

10CVSS6.6AI score0.9166EPSS
SaveExploits27
ICS
ICS
•added 2021/07/13 12:00 a.m.•75 views

Siemens SIMATIC Software Products (Update B)

1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION : Low attack complexity Vendor : Siemens Equipment : SIMATIC Software Products Vulnerability : Incorrect Permission Assignment for Critical Resource 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-194-06...

8.8CVSS8.8AI score0.00228EPSS
SaveExploits0References11
NVD
NVD
•added 2021/06/28 1:15 p.m.•35 views

CVE-2021-31337

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products SINAMICS SL15...

9.8CVSS0.01678EPSS
SaveExploits0References1
Prion
Prion
•added 2021/06/28 1:15 p.m.•37 views

Authentication flaw

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products SINAMICS SL15...

6.8CVSS9.4AI score0.01678EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2021/06/28 1:15 p.m.•11 views

CVE-2021-31337

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products SINAMICS SL15...

9.8CVSS7.1AI score0.01678EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2021/06/28 12:24 p.m.•47 views

CVE-2021-31337

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products SINAMICS SL15...

9.7AI score0.01678EPSS
SaveExploits0References1
CVE
CVE
•added 2021/06/28 12:24 p.m.•80 views

CVE-2021-31337

The CVE-2021-31337 issue concerns the Telnet service of the SIMATIC HMI Comfort Panels component. The Telnet service does not require authentication, potentially allowing a remote attacker to gain access if the service is enabled. Affected products/versions include SINAMICS SL150 (all versions), ...

9.8CVSS9.4AI score0.01678EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/06/28 12:00 a.m.•9 views

CVE-2021-31337: Missing Authentication for Critical Function

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products SINAMICS SL15...

9.8CVSS6AI score0.01678EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2021/06/28 12:00 a.m.•26 views

PT-2021-19246

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels affected versions not specified SINAMICS SL150: All versions SINAMICS SM150: All versions SINAMICS SM150i: All versions Description The issue concerns the Telnet service of the SIMATIC HMI Comfort Panels system...

9.8CVSS6.9AI score0.01678EPSS
SaveExploits0References3
OSV
OSV
•added 2021/06/08 8:15 p.m.•15 views

CVE-2021-31340

A vulnerability has been identified in SIMATIC RF166C All versions V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V4.0. Affected devices do not properly handle large numbers of incoming connections. A...

7.5CVSS5.7AI score0.00988EPSS
SaveExploits0References1
NVD
NVD
•added 2021/06/08 8:15 p.m.•34 views

CVE-2021-31340

A vulnerability has been identified in SIMATIC RF166C All versions V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V4.0. Affected devices do not properly handle large numbers of incoming connections. A...

7.5CVSS0.00988EPSS
SaveExploits0References1
Prion
Prion
•added 2021/06/08 8:15 p.m.•26 views

Code injection

A vulnerability has been identified in SIMATIC RF166C All versions V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V4.0. Affected devices do not properly handle large numbers of incoming connections. A...

5CVSS7.3AI score0.00988EPSS
SaveExploits0References1Affected Software25
attackerkb
attackerkb
•added 2021/06/08 8:15 p.m.•12 views

CVE-2021-31340

A vulnerability has been identified in SIMATIC RF166C All versions V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V4.0. Affected devices do not properly handle large numbers of incoming connections. A...

7.5CVSS6.8AI score0.00988EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2021/06/08 7:47 p.m.•37 views

CVE-2021-31340

A vulnerability has been identified in SIMATIC RF166C All versions V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V4.0. Affected devices do not properly handle large numbers of incoming connections. A...

7.5AI score0.00988EPSS
SaveExploits0References1
CVE
CVE
•added 2021/06/08 7:47 p.m.•80 views

CVE-2021-31340

CVE-2021-31340 affects Siemens SIMATIC RF devices (RF166C/185C/186C/186CI/188C/188CI; RF360R; Reader RF610R/615R/650R/680R/685R) with multiple versions vulnerable to Uncontrolled Resource Consumption (CWE-400) causing Denial-of-Service by not handling large numbers of incoming connections. Affect...

7.5CVSS7.3AI score0.00988EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/06/08 12:00 a.m.•6 views

CVE-2021-31340: Uncontrolled Resource Consumption

A vulnerability has been identified in SIMATIC RF166C All versions V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V1.1 and V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V3.0 V4.0. Affected devices do not properly handle large numbers of incoming connections. A...

7.5CVSS5.6AI score0.00988EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2021/06/08 12:00 a.m.•21 views

Siemens SIMATIC 多款产品资源管理错误漏洞

The SIMATIC RF185C, RF186C/CI and RF188C/CI are communication modules for direct connection of image recognition systems to PROFINET IO/Ethernet and OPC UA.The SIMATIC RF300R is a compact RFID reader. A denial of service vulnerability exists in Siemens SIMATIC RFID Readers. An attacker could...

7.5CVSS5.6AI score0.00988EPSS
SaveExploits0References4
ICS
ICS
•added 2021/06/08 12:00 a.m.•112 views

Siemens SIMATIC NET CP 443-1 OPC UA

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC NET CP 443-1 OPC UA Vulnerabilities: Improper Input Validation, Improper Restriction of Operations within the Bounds of a Memory Buffer, Incorrect Calculation, Classic Buffer...

9.8CVSS9.4AI score0.17245EPSS
SaveExploits2References11
ICS
ICS
•added 2021/06/08 12:00 a.m.•58 views

Siemens SIMATIC RFID (Update B)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SIMATIC RF Products Vulnerability: Uncontrolled Resource Consumption 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-21-159-13 Siemens SIMATIC RFID Readers...

7.5CVSS7.7AI score0.00988EPSS
SaveExploits0References11
ICS
ICS
•added 2021/06/08 12:00 a.m.•83 views

Siemens SIMATIC TIM libcurl

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC TIM libcurl Vulnerabilities: Exposure of Sensitive Information to an Unauthorized Actor, Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of these...

7.5CVSS8.5AI score0.04631EPSS
SaveExploits2References11
Rows per page
Query Builder