Lucene search
+L

4843 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/09 12:00 a.m.•9 views

CVE-2021-40359: Improper Limitation of a Pathname to a Restricted Directory

A vulnerability has been identified in OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd4, OpenPCS 7 V9.1 All versions, SIMATIC BATCH V8.2 All versions, SIMATIC BATCH V9.0 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC NET PC Software V14 All versions, SIMATIC NET PC...

7.7CVSS5.6AI score0.01174EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2021/11/09 12:00 a.m.•24 views

Siemens SIMATIC PCS 7和SIMATIC WinCC 路径遍历漏洞

Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, a German company. SIMATIC PCS 7 is a process control system and SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. A path traversal vulnerability exists in SIMATIC PCS 7 and SIMATIC WinCC. The...

9.9CVSS5.8AI score0.01274EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/09 12:00 a.m.•6 views

CVE-2020-10054: Improper Input Validation

A vulnerability has been identified in SIMATIC RTLS Locating Manager All versions V2.12. The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the...

5.5CVSS5.6AI score0.00208EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2021/11/09 12:00 a.m.•19 views

PT-2021-22877 · Siemens · Openpcs 7 +5

Name of the Vulnerable Software and Affected Versions: OpenPCS 7 versions 7.0 through 9.1 SIMATIC BATCH versions 8.2 through 9.1 SIMATIC NET PC Software versions 14 through 17 SIMATIC PCS 7 versions 8.2 through 9.1 SIMATIC Route Control versions 8.2 through 9.1 SIMATIC WinCC versions 7.4 through ...

7.7CVSS7.3AI score0.01174EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/09 12:00 a.m.•10 views

CVE-2020-10052: Insertion of Sensitive Information into Log File

A vulnerability has been identified in SIMATIC RTLS Locating Manager All versions V2.12. The affected application writes sensitive data, such as usernames and passwords in log files. A local attacker with access to the log files could use this information to launch further attacks...

5.5CVSS5.7AI score0.00232EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2021/11/09 12:00 a.m.•3 views

PT-2021-9135

Name of the Vulnerable Software and Affected Versions SIMATIC RTLS Locating Manager versions prior to V2.12 Description A vulnerability has been identified where the affected application writes sensitive data, such as database credentials, in configuration files. A local attacker with access to t...

5.5CVSS0.00155EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2021/11/09 12:00 a.m.•8 views

PT-2021-9134

Name of the Vulnerable Software and Affected Versions SIMATIC RTLS Locating Manager versions prior to V2.12 Description A vulnerability has been identified where the affected application writes sensitive data, such as usernames and passwords, in log files. A local attacker with access to the log...

5.5CVSS0.00232EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2021/11/09 12:00 a.m.•8 views

PT-2021-9136

Name of the Vulnerable Software and Affected Versions SIMATIC RTLS Locating Manager versions prior to V2.12 Description A issue has been identified where the application does not properly handle the import of large configuration files. This could allow a local attacker to import a specially craft...

5.5CVSS0.00208EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/09 12:00 a.m.•4 views

CVE-2021-40358: Improper Limitation of a Pathname to a Restricted Directory

A vulnerability has been identified in SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions V9.0 SP3 UC04, SIMATIC PCS 7 V9.1 All versions V9.1 SP1, SIMATIC WinCC V15 and earlier All versions V15 SP1 Update 7, SIMATIC WinCC V16 All versions V16 Update 5, SIMATIC WinCC V17 All versions...

9.9CVSS5.6AI score0.01274EPSS
SaveExploits0References3
ICS
ICS
•added 2021/11/09 12:00 a.m.•175 views

Siemens SIMATIC WinCC (Update E)

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

9.9CVSS7.5AI score0.01274EPSS
SaveExploits0References12
ICS
ICS
•added 2021/11/09 12:00 a.m.•57 views

Siemens SIMATIC RTLS Locating Manager

1. EXECUTIVE SUMMARY CVSS v3 5.5 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SIMATIC RTLS Locating Manager Vulnerabilities: Insertion of Sensitive Information into Log File, Cleartext Storage of Sensitive Information, Improper Input Validation 2. RISK EVALUATION Successful...

5.5CVSS6AI score0.00232EPSS
SaveExploits0References11
NVD
NVD
•added 2021/10/12 10:15 a.m.•40 views

CVE-2021-27395

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

8.1CVSS0.00801EPSS
SaveExploits0References1
Prion
Prion
•added 2021/10/12 10:15 a.m.•33 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

5.5CVSS7.8AI score0.00801EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2021/10/12 9:49 a.m.•46 views

CVE-2021-27395

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

8.1AI score0.00801EPSS
SaveExploits0References1
CVE
CVE
•added 2021/10/12 9:49 a.m.•64 views

CVE-2021-27395

CVE-2021-27395 affects Siemens SIMATIC Process Historian (versions 2013 and earlier; 2014 before SP3 Update 6; 2019; 2020). The issue is missing authentication on interfaces used for critical functions, enabling a malicious user to insert, modify, or delete data. CVSS v3 base score is 9.8 (vector...

8.1CVSS7.8AI score0.00801EPSS
SaveExploits0References1Affected Software4
Positive Technologies
Positive Technologies
•added 2021/10/12 12:00 a.m.•4 views

PT-2021-17434

Name of the Vulnerable Software and Affected Versions SIMATIC Process Historian versions prior to 2014 SP3 Update 6 SIMATIC Process Historian 2019 versions SIMATIC Process Historian 2020 versions Description A vulnerability has been identified in the software where an interface used for critical...

8.1CVSS0.00801EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2021/10/12 12:00 a.m.•21 views

Siemens Simatic Process Historian 访问控制错误漏洞

Siemens Simatic Process Historian is a centralized archiving system from Siemens, Germany. An authentication vulnerability exists in Siemens SIMATIC Process Historian, which arises from a lack of authentication of interfaces used for critical functions in the software, and can be exploited by an...

8.1CVSS5.7AI score0.00801EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/10/12 12:00 a.m.•5 views

CVE-2021-27395: Missing Authentication for Critical Function

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

8.1CVSS5.7AI score0.00801EPSS
SaveExploits0References2
ICS
ICS
•added 2021/10/12 12:00 a.m.•67 views

Siemens SIMATIC Process Historian

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC Process Historian Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could enable the execution of...

8.1CVSS8.6AI score0.00801EPSS
SaveExploits0References11
Positive Technologies
Positive Technologies
•added 2021/10/06 12:00 a.m.•18 views

PT-2021-7272 · Siemens · Simatic Step 7

Name of the Vulnerable Software and Affected Versions: SIMATIC STEP 7 TIA Portal V15 All versions SIMATIC STEP 7 TIA Portal V16 All versions V16 Update 5 SIMATIC STEP 7 TIA Portal V17 All versions V17 Update 2 Description: A vulnerability has been identified due to improper access control in the...

7.8CVSS7.7AI score0.0024EPSS
SaveExploits0References5
Rows per page
Query Builder