Lucene search
+L

4182 matches found

Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.14 views

Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2252)

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253. This plugin only works with Tenable.ot. Please visit...

6.1CVSS5.5AI score0.01253EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.17 views

Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2256)

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257. This plugin only works with Tenable.ot. Please visit...

7.8CVSS5.5AI score0.03609EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.41 views

Siemens SIMATIC S7-1200 Cross-Site Request Forgery (CVE-2015-5698)

Cross-site request forgery CSRF vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. This plugin only works with Tenable.ot. Please visit...

7.5CVSS5.5AI score0.03339EPSS
SaveExploits2References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.24 views

Siemens SIMATIC S7-1500 Protection Mechanism Failure (CVE-2016-2201)

Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network...

5.3CVSS6.3AI score0.02917EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.22 views

Siemens Industrial Real-Time Devices Improper Input Validation (CVE-2019-10923)

A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family incl. SIPLUS NET variants,...

7.5CVSS7.3AI score0.01401EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.26 views

Siemens SIMATIC S7-300 Denial of Service (CVE-2015-2177)

Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service defect-mode transition via crafted packets on 1 TCP port 102 or 2 Profibus. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...

7.8CVSS5.5AI score0.3468EPSS
SaveExploits5References7
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.24 views

Siemens SIMATIC S7-1500 CPU Improper Input Validation (CVE-2018-16559)

A vulnerability has been identified in SIMATIC S7-1500 CPU All versions = V2.0 and V2.5, SIMATIC S7-1500 CPU All versions = V1.8.5. Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device...

7.8CVSS7.1AI score0.01986EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.17 views

Siemens SIMATIC Controller Web Servers Uncaught Exception (CVE-2020-15796)

A vulnerability has been identified in SIMATIC ET 200SP Open Controller incl. SIPLUS variants V20.8, SIMATIC S7-1500 Software Controller V20.8. The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a...

7.5CVSS7.3AI score0.01591EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.61 views

Siemens SIMATIC S7-1200 and S7-1500 CPU Families Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2020-15782)

A vulnerability has been identified in SIMATIC Drive Controller family All versions V2.9.2, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V21.9, SIMATIC S7-1200 CPU family incl...

9.8CVSS8.5AI score0.05184EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.29 views

Siemens SIMATIC, SIMOCODE, SINAMICS, SITOP, and TIM Out-of-Bounds Read (CVE-2019-6568)

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with...

7.5CVSS7.1AI score0.01401EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.40 views

Siemens SIMATIC S7-1200 CPU Family Denial of Service (CVE-2013-2780)

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to UDP port 161 aka the SNMP port. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

7.8CVSS5.5AI score0.02392EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.17 views

Siemens SIMATIC S7-1500 Open Redirect (CVE-2014-2248)

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. This plugin only works with Tenable.ot. Please visi...

4.3CVSS5.8AI score0.02204EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.17 views

Siemens SIMATIC S7-1500 & S7-1200 Cross-Site Request Forgery (CVE-2014-2249)

Cross-site request forgery CSRF vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. This plugin only works...

5.8CVSS5.5AI score0.01344EPSS
SaveExploits1References7
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.26 views

Siemens SIMATIC S7-1200 Improper Privilege Management (CVE-2016-2846)

Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a user program block protection mechanism via unspecified vectors. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable...

6.5CVSS6.6AI score0.01691EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.31 views

Siemens SIMATIC S7-1500 Improper Input Validation (CVE-2016-2200)

Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service STOP mode transition via crafted packets on TCP port 102. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300...

7.8CVSS7.4AI score0.06371EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.30 views

Siemens SIMATIC Denial of Service (CVE-2012-3016)

Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

7.8CVSS5.8AI score0.03464EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.17 views

Siemens SIMATIC S7-200 SMART CPU Family Uncontrolled Resource Consumption (CVE-2020-7584)

A vulnerability has been identified in SIMATIC S7-200 SMART CPU family All versions = V2.2 = V2.2 V2.5.1. Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service...

7.5CVSS7.1AI score0.01044EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.28 views

Siemens SIMATIC Improper Certificate Validation (CVE-2012-3037)

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate. This plugin only works with Tenable.ot. Plea...

4.3CVSS7.2AI score0.01472EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.60 views

Siemens SIMATIC Products Use of a Broken or Risky Cryptographic Algorithm (CVE-2019-10929)

Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices. This plugin only work...

5.9CVSS6AI score0.00978EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.19 views

Siemens SIMATIC S7-1200 Insufficient Entropy in PRNG (CVE-2014-2250)

The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...

8.3CVSS5.6AI score0.03156EPSS
SaveExploits1References4
Rows per page
Query Builder