Lucene search
+L

4182 matches found

Positive Technologies
Positive Technologies
added 2023/05/09 12:0 a.m.7 views

PT-2023-21995 · Siemens · Simatic Cloud Connect 7 Cc712 +1

Name of the Vulnerable Software and Affected Versions: SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1 Description: A vulnerability has been identified where the web-based management of affected devices does not properly validate user...

7.2CVSS7.5AI score0.01535EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2023/05/09 12:0 a.m.9 views

Siemens SIMATIC Cloud Connect 信息泄露漏洞

SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. An information disclosure vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be...

7.5CVSS6.2AI score0.00718EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2023/05/09 12:0 a.m.16 views

Siemens SIMATIC Cloud Connect 路径遍历漏洞

SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A path traversal vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited by a...

3.8CVSS6.8AI score0.00684EPSS
SaveExploits0References3
NCSC
NCSC
added 2023/05/09 12:0 a.m.20 views

Vulnerabilities fixed in Siemens products

Siemens has fixed vulnerabilities in SIMATIC Cloud Connect, Siveillance, SINEC, Solid Edge and Scalance products. The vulnerabilities potentially enable a malicious party to launch attacks execute attacks that could result in the following categories of damage: Denial-of-Service DoS Manipulation ...

9.9CVSS8.2AI score0.1654EPSS
SaveExploits6
CNNVD
CNNVD
added 2023/05/09 12:0 a.m.11 views

Siemens SIMATIC Cloud Connect 安全漏洞

SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. An information disclosure vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be...

5.3CVSS6.2AI score0.00646EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2023/05/09 12:0 a.m.12 views

Siemens SIMATIC Cloud Connect 命令注入漏洞

SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A command injection vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited b...

7.2CVSS8.4AI score0.01535EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2023/05/09 12:0 a.m.11 views

PT-2023-22162 · Siemens · Simatic Cloud Connect 7 Cc712 +1

Name of the Vulnerable Software and Affected Versions: SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.0 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.0 Description: A path traversal vulnerability has been identified in the upload feature of the web-based management of the affected...

3.8CVSS3.8AI score0.00684EPSS
SaveExploits0References2
ICS
ICS
added 2023/05/09 12:0 a.m.33 views

Siemens SIMATIC Cloud Connect 7

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

7.6CVSS7.8AI score0.01535EPSS
SaveExploits0References12
CNNVD
CNNVD
added 2023/05/09 12:0 a.m.14 views

Siemens SIMATIC Cloud Connect 安全漏洞

SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. Siemens SIMATIC Cloud Connect 7 suffers from a use of hard-coded password vulnerability that could be...

4.3CVSS6.8AI score0.00387EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.46 views

Siemens SIMATIC CP Out-of-Bounds Read (CVE-2020-9272)

ProFTPD 1.3.7 has an out-of-bounds OOB read vulnerability in modcap via the captext.c captotext function. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...

7.5CVSS6.2AI score0.0211EPSS
SaveExploits0References9
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.18 views

Siemens SIMATIC NET CP Modules Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2021-33737)

A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 343-1 ERPC All versions, SIMATIC CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP...

7.8CVSS7.1AI score0.01056EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.37 views

Siemens SIMATIC CP Use After Free (CVE-2020-9273)

In ProFTPD 1.3.7, it is possible to corrupt the memory pool by interrupting the data transfer channel. This triggers a use-after-free in allocpool in pool.c, and possible remote code execution. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...

9CVSS6.7AI score0.12045EPSS
SaveExploits1References14
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.12 views

Siemens SIMATIC CP Cleartext Storage of Sensitive Information (CVE-2021-33716)

A vulnerability has been identified in SIMATIC CP 1543-1 incl. SIPLUS variants All versions V3.0, SIMATIC CP 1545-1 All versions V1.1. An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext. This plugin only works with Tenable.ot...

6.5CVSS6.4AI score0.00253EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.24 views

Siemens SIMATIC CP 1543-1 Improper Privilege Management (CVE-2016-8561)

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Users with elevated privileges to TIA-Portal and project data on the engineering station could possibly get privileged access on affected devices. This plugin only works with...

6.6CVSS6.4AI score0.01585EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.16 views

Siemens SIMATIC CP 44x-1 RNA Uncontrolled Resource Consumption (CVE-2022-27640)

A vulnerability has been identified in SIMATIC CP 442-1 RNA All versions V1.5.18, SIMATIC CP 443-1 RNA All versions V1.5.18. The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming...

6.5CVSS6.4AI score0.00354EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.31 views

Siemens SIMATIC NET CP 443-1 OPC UA Concurrent Execution Using Shared Resource with Improper Synchronization (CVE-2016-4955)

ntpd in NTP 4.x before 4.2.8p8, when autokey is enabled, allows remote attackers to cause a denial of service peer-variable clearing and association outage by sending 1 a spoofed crypto-NAK packet or 2 a packet with an incorrect MAC value at a certain time. This plugin only works with Tenable.ot...

5.9CVSS6.2AI score0.08771EPSS
SaveExploits0References17
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.33 views

Siemens SIMATIC NET CP 443-1 OPC UA Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2017-6458)

Multiple buffer overflows in the ctlput functions in NTP before 4.2.8p10 and 4.3.x before 4.3.94 allow remote authenticated users to have unspecified impact via a long variable. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. ...

8.8CVSS7.8AI score0.06515EPSS
SaveExploits0References9
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.35 views

Siemens SIMATIC NET CP 443-1 OPC UA Improper Input Validation (CVE-2016-4956)

ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service interleaved-mode transition and time change via a spoofed broadcast packet. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-1548. This plugin only works with Tenable.ot. Please visit...

5.3CVSS6.6AI score0.16351EPSS
SaveExploits0References18
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.40 views

Siemens SIMATIC Communication Processor (CVE-2015-8214)

A vulnerability has been identified in SIMATIC NET CP 342-5 incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Advanced incl. SIPLUS variants All versions V3.0.44, SIMATIC NET CP 343-1 Lean incl. SIPLUS variants All versions V3.1.1, SIMATIC NET CP 343-1 Standard incl. SIPLUS variants All...

9.7CVSS5.3AI score0.02149EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.41 views

Siemens Industrial Products Deadlock (CVE-2022-43767)

A vulnerability has been identified in SIMATIC CP 1242-7 V2 All versions, SIMATIC CP 1243-1 All versions, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions, SIMATIC CP 1243-7 LTE EU All versions, SIMATIC CP 1243-7 LTE US All...

7.5CVSS7.1AI score0.00723EPSS
SaveExploits0References3
Rows per page
Query Builder