•added 2014/11/26 12:00 a.m.•6 views

CVE-2014-8552: Exposure of Sensitive Information to an Unauthorized Actor

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets...

5CVSS6AI score0.02047EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2014/11/26 12:00 a.m.•4 views

PT-2014-8612

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC WinCC versions 7.0 through 7.3 before Update 2 Siemens SIMATIC PCS 7 versions 7.1 through 8.1 Siemens TIA Portal version 13 before Update 6 Description The issue allows remote attackers to execute arbitrary code via crafted...

10CVSS0.05271EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2014/11/26 12:00 a.m.•3 views

PT-2014-8613

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC WinCC versions 7.0 through 7.0 SP3 Siemens SIMATIC WinCC versions 7.2 through 7.2 before Update 9 Siemens SIMATIC WinCC versions 7.3 through 7.3 before Update 2 Siemens SIMATIC PCS 7 versions 7.1 through 7.1 SP4 Siemens SIMATIC...

5CVSS0.02047EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/11/26 12:00 a.m.•5 views

CVE-2014-8551: Improper Control of Generation of Code

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets...

10CVSS6.5AI score0.05271EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2013/03/03 12:00 a.m.•30 views

PT-2013-43: Hard-coded credentials in Siemens WinCC and SIMATIC PCS 7

The specialists of the Positive Research center have detected a vulnerability in Siemens WinCC and SIMATIC PCS 7 related to hard-coded credentials used in the login system . Attackers with network access and knowledge of the credentials could log into the Web Navigator Web applications as an...

7.5CVSS6.7AI score0.01934EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2013/01/13 12:00 a.m.•29 views

PT-2013-42: SQL Injection in Siemens WinCC and SIMATIC PCS 7

The specialists of the Positive Research center have detected "SQL Injection" vulnerability in Siemens WinCC and SIMATIC PCS 7. The WinCC Web Navigator 7.2 and Runtime Client OPC protocol have input filtering in the login screen an attacker can overcome, allowing injection of SQL statements into...

10CVSS7.3AI score0.01784EPSS
SaveExploits0References5
ICS
ICS
•added 2012/04/26 6:00 a.m.•79 views

Siemens SIMATIC STEP 7 DLL Vulnerability

Overview Siemens has released a software update for a DLL hijacking vulnerability in SIMATIC STEP 7 and SIMATIC PCS 7 software. Previous versions of SIMATIC STEP 7 and PCS 7 allowed the loading of malicious DLL files into the STEP 7 project folder that can be used to attack the system on which ST...