Lucene search
+L

124 matches found

CVE
CVE
added 2019/04/17 1:40 p.m.110 views

CVE-2019-6575

CVE-2019-6575 affects Siemens industrial products using OPC UA, including SIMATIC CP443-1 OPC UA, ET 200 Open Controller CPU 1515SP PC2, HMI Outdoor Panels (7"/15"), HMI Comfort Panels (4"–22"), KTP Mobile Panels, IPC DiagMonitor, NET PC Software, RF188C, RF600R, S7‑1500 family, WinCC OA/Runtime,...

7.8CVSS7.4AI score0.01646EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
added 2019/04/09 12:00 a.m.11 views

PT-2019-2034 · Siemens · Simatic Hmi Comfort Outdoor Panels 7" & 15" +16

Name of the Vulnerable Software and Affected Versions: SIMATIC CP 443-1 OPC UA versions prior to the fixed version SIMATIC ET 200SP Open Controller CPU 1515SP PC2 versions prior to V2.7 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15.1 Upd 4 SIMATIC HMI Comfort Panels 4" - 22"...

7.8CVSS7.5AI score0.01646EPSS
SaveExploits0References3
CNVD
CNVD
added 2018/03/22 12:00 a.m.21 views

Denial of Service Vulnerability in Multiple Siemens Products (CNVD-2018-06025)

The SIMATIC CP 343-1 Advanced is an Ethernet communication module that supports PROFINET, the new generation of automation bus standards based on industrial Ethernet technology. 1500 is a programmable logic controller. A denial of service vulnerability exists in several Siemens products. An...

6.5CVSS6.7AI score0.00547EPSS
SaveExploits0References1
OpenVAS
OpenVAS
added 2018/02/20 12:00 a.m.147 views

Siemens SIMATIC CP Device Detection (FTP)

This script performs FTP based detection of Siemens SIMATIC CP devices. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

7.1AI score
SaveExploits0
OpenVAS
OpenVAS
added 2018/02/01 12:00 a.m.13 views

Siemens SIMATIC CP Device Detection (SNMP)

This script performs SNMP based detection of Siemens SIMATIC CP devices. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...

7.1AI score
SaveExploits0
OpenVAS
OpenVAS
added 2018/02/01 12:00 a.m.22 views

Siemens SIMATIC CP Device Detection Consolidation

Consolidation of Siemens SIMATIC CP device detections. Copyright C 2018 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free software; you ca...

7.1AI score
SaveExploits0References1
OpenVAS
OpenVAS
added 2018/02/01 12:00 a.m.102 views

Siemens SIMATIC CP Device Detection (HTTP)

This script performs HTTP based detection of Siemens SIMATIC CP devices. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...

7.1AI score
SaveExploits0
NVD
NVD
added 2017/07/07 5:29 p.m.15 views

CVE-2017-6868

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

8.1CVSS8.2AI score0.04174EPSS
SaveExploits0References4
Prion
Prion
added 2017/07/07 5:29 p.m.17 views

Authentication flaw

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

6.8CVSS8AI score0.04174EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2017/07/07 5:00 p.m.28 views

CVE-2017-6868

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

8.1AI score0.04174EPSS
SaveExploits0References4
ThreatPost
ThreatPost
added 2017/06/23 2:07 p.m.14 views

Siemens Patches Two Vulnerabilities in SIMATIC CP and XHQ

Siemens patched two vulnerabilities in products commonly found in industrial control system setups this week. If exploited the flaws could allow an attacker to perform administrative actions or gain read access to sensitive data on affected systems. Siemens patched one issue .PDF on Tuesday and t...

0.8AI score
SaveExploits0References3
ICS
ICS
added 2017/06/22 12:00 a.m.39 views

Siemens SIMATIC CP 44x-1 Redundant Network Access Modules

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC CP 44x-1 Redundant Network Access RNA modules Vulnerability: Improper Authentication AFFECTED PRODUCTS The following versions of the SIMATIC CP 44x-1 RNA, which connect SIMATIC S7-400 CPUs t...

8.1CVSS8.8AI score0.04174EPSS
SaveExploits0References3
zdt
zdt
added 2017/01/12 12:00 a.m.55 views

Siemens SIMATIC CP 343-1 Advanced IKEv1 Cipher Suite Configuration Vulnerability

The SIMATIC CP 343-1 Advanced product allows configuration of the IKEv1 cipher suite configuration, which specifies the IKE and Encapsulating Security Payload ESP supported algorithms, with one cipher for each setting. It is evaluated that the configuration is not consistent with the supported...

6.9AI score
SaveExploits0
Prion
Prion
added 2016/11/23 11:59 a.m.22 views

Server side request forgery (ssrf)

A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...

6.8CVSS7AI score0.01089EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2016/11/23 11:00 a.m.37 views

CVE-2016-8672

A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...

5.1AI score0.01852EPSS
SaveExploits0References1
CNVD
CNVD
added 2016/11/21 12:00 a.m.8 views

SIEMENS SIMATIC CP 1543-1 Device Privilege Elevation Vulnerability

The SIEMENS SIMATIC CP 1543-1 is a communication processor with integrated firewall, VPN, security protocols, data encryption, and other security features that provides network connectivity and secure communication for s7-1500 controllers. An elevation of privilege vulnerability exists in the...

6.6CVSS7.5AI score0.01585EPSS
SaveExploits0References1
NVD
NVD
added 2016/11/18 9:59 p.m.25 views

CVE-2016-8562

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

7.5CVSS5.3AI score0.03624EPSS
SaveExploits0References5
Prion
Prion
added 2016/11/18 9:59 p.m.24 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Users with elevated privileges to TIA-Portal and project data on the engineering station could possibly get privileged access on affected devices...

6CVSS6.8AI score0.01585EPSS
SaveExploits0References4
Prion
Prion
added 2016/11/18 9:59 p.m.28 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

3.5CVSS6.8AI score0.03624EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2016/11/18 9:00 p.m.43 views

CVE-2016-8562

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

5.1AI score0.03624EPSS
SaveExploits0References4
Rows per page
Query Builder