Lucene search
+L

316 matches found

Prion
Prion
•added 2019/03/26 3:29 p.m.•30 views

Hardcoded credentials

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...

5CVSS7AI score0.0156EPSS
SaveExploits0References1Affected Software1
NVD
NVD
•added 2019/03/26 3:29 p.m.•37 views

CVE-2014-5434

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...

9.8CVSS9.6AI score0.0156EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/03/26 3:17 p.m.•32 views

CVE-2014-5432

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...

9.6AI score0.02573EPSS
SaveExploits0References1
CVE
CVE
•added 2019/03/26 3:17 p.m.•63 views

CVE-2014-5432

CVE-2014-5432 affects Baxter SIGMA Spectrum Infusion System v6.05 (model 35700BAX) with Wireless Battery Module (WBM) v16. The root cause includes unauthenticated remote SSH access (Port 22) and related credential exposure. Consequences: remote attacker could modify WBM configuration and retrieve...

9.8CVSS9.3AI score0.02573EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/03/26 3:07 p.m.•35 views

CVE-2014-5433

An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16, which may allow an attacker to gain access the hos...

9.9AI score0.02062EPSS
SaveExploits0References1
CVE
CVE
•added 2019/03/26 3:07 p.m.•75 views

CVE-2014-5433

CVE-2014-5433 affects Baxter’s SIGMA Spectrum Infusion System (Version 6.05, model 35700BAX) with the Wireless Battery Module (WBM) Version 16. The connected disclosures describe multiple issues: a hard-coded password enabling unauthorized management access (CWE-259), an authentication bypass tie...

9.8CVSS9.7AI score0.02062EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/03/26 2:59 p.m.•37 views

CVE-2014-5434

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...

9.6AI score0.0156EPSS
SaveExploits0References1
CVE
CVE
•added 2019/03/26 2:59 p.m.•56 views

CVE-2014-5434

The CVE-2014-5434 entry concerns Baxter’s SIGMA Spectrum Infusion System: version 6.05 (model 35700BAX) with Wireless Battery Module (WBM) version 16, which contains a default, hard-coded credential used with FTP. The vulnerability allows remote access in some vectors (three vulnerabilities remot...

9.8CVSS9.3AI score0.0156EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/26 12:00 a.m.•9 views

CVE-2014-5433: Cleartext Storage of Sensitive Information

An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16, which may allow an attacker to gain access the hos...

9.8CVSS6.2AI score0.02062EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/26 12:00 a.m.•4 views

CVE-2014-5434: Use of Hard-coded Password

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new...

9.8CVSS5.8AI score0.0156EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/26 12:00 a.m.•10 views

CVE-2014-5431: Use of Hard-coded Password

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password...

6.8CVSS5.8AI score0.00378EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/26 12:00 a.m.•7 views

CVE-2014-5432: DEPRECATED: Authentication Bypass Issues

Baxter SIGMA Spectrum Infusion System version 6.05 model 35700BAX with wireless battery module WBM version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access...

9.8CVSS5.9AI score0.02573EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2019/03/26 12:00 a.m.•3 views

PT-2019-7130

Name of the Vulnerable Software and Affected Versions Baxter SIGMA Spectrum Infusion System version 6.05 Description The issue concerns a default account with hard-coded credentials used in conjunction with the FTP protocol. It is specified that no files can be transferred to or from the wireless...

9.8CVSS0.0156EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/03/26 12:00 a.m.•4 views

PT-2019-7128

Name of the Vulnerable Software and Affected Versions Baxter SIGMA Spectrum Infusion System version 6.05 Description The issue allows remote access via Port 22/SSH without authentication, enabling a remote attacker to make unauthorized configuration changes to the wireless battery module WBM and...

9.8CVSS0.02573EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/03/26 12:00 a.m.•2 views

PT-2019-7127

Name of the Vulnerable Software and Affected Versions Baxter SIGMA Spectrum Infusion System version 6.05 Description The issue concerns a hard-coded password in the wireless battery module of the Baxter SIGMA Spectrum Infusion System. This password provides access to basic biomedical information,...

6.8CVSS0.00378EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/03/26 12:00 a.m.•3 views

PT-2019-7129

Name of the Vulnerable Software and Affected Versions Baxter SIGMA Spectrum Infusion System version 6.05 Description An unauthenticated remote attacker may be able to execute commands to view wireless account credentials stored in cleartext, potentially allowing access to the host network...

9.8CVSS0.02062EPSS
SaveExploits0References2
NVD
NVD
•added 2018/12/09 7:29 p.m.•23 views

CVE-2018-19983

An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.. Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending...

6.5CVSS6.5AI score0.00463EPSS
SaveExploits0References1
CVE
CVE
•added 2018/12/09 7:00 p.m.•74 views

CVE-2018-19983

CVE-2018-19983 affects Sigma Design Z-Wave devices (S0 through S2). An attacker can perform a DoS by repeatedly sending divided Nonce Get frames (0x98 0x81). In S0, upon receiving a Nonce Get, the node generates and sends a new nonce, then waits; if another Nonce Get arrives, the previous nonce i...

6.5CVSS6.4AI score0.00463EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2018/12/09 7:00 p.m.•37 views

CVE-2018-19983

An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.. Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending...

6.5AI score0.00463EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2018/12/09 12:00 a.m.•2 views

PT-2018-15185

Name of the Vulnerable Software and Affected Versions Sigma Design Z-Wave S0 through S2 devices Description An issue was discovered in Sigma Design Z-Wave devices, where an attacker can conduct a Denial of Service DoS attack against the Z-Wave S0 Security version product. The attack involves...

6.5CVSS0.00463EPSS