13 matches found
Siemens RUGGEDCOM ROS Improper Input Validation (CVE-2025-40935)
Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device. This plugin only works with Tenable.ot...
Network Mirroring in Siemens RUGGEDCOM Incorrect Provision of Specified Functionality (CVE-2023-24845)
The affected products insufficiently block data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior. This plugin onl...
Resource Allocation in Siemens RUGGEDCOM Allocation of Resources Without Limits or Throttling (CVE-2023-39269)
The web server of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause total loss of availability of the web server, which might recover after the attack is over. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM ROS Devices Observable Timing Discrepancy (CVE-2021-42016)
A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sensitive data. If a threat actor were to exploit this, the data integrity and security could be compromised. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM ROS Devices Integer Overflow or Wraparound (CVE-2021-42019)
Within a third-party component, the process to allocate partition size fails to check memory boundaries. Therefore, if a large amount is requested by an attacker, due to an integer-wrap around, it could result in a small size being allocated instead. This plugin only works with Tenable.ot. Please...
Siemens RUGGEDCOM ROS Devices Improper Neutralization of Input During Web Page Generation (CVE-2021-37208)
Improper neutralization of special characters on the web server configuration page could allow an attacker, in a privileged position, to retrieve sensitive information via cross-site scripting. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...
Siemens RUGGEDCOM ROS Devices Improper Check for Unusual or Exceptional Conditions (CVE-2021-42020)
The third-party component, in its TFTP functionality fails to check for null terminations in file names. If an attacker were to exploit this, it could result in data corruption, and possibly a hard-fault of the application. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM ROS Information Disclosure Vulnerability (CNVD-2024-31236)
Siemens RuggedCom ROS is an operating system from Siemens, Germany, used in the RuggedCom series of switches. An information disclosure vulnerability exists in Siemens RUGGEDCOM ROS, which can be exploited by an attacker to retrieve a MACSEC key and access decrypt Ethernet frames sent by an...
Siemens RUGGEDCOM ROS
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens RUGGEDCOM ROS has an unspecified vulnerability (CNVD-2022-17784)
Siemens RuggedCom ROS is an operating system used in the RuggedCom family of switches from Siemens, Germany. Siemens RUGGEDCOM ROS has a security vulnerability that could be exploited by attackers to act as a man-in-the-middle and eavesdrop on encrypted communications...
Siemens RUGGEDCOM 安全特征问题漏洞
Siemens RuggedCom ROS is an operating system used in the RuggedCom family of switches from Siemens, Germany. Siemens RUGGEDCOM ROS has a security vulnerability that could be exploited by attackers to act as a man-in-the-middle and eavesdrop on encrypted communications...
CVE-2014-2590
The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service interface outage via crafted HTTP packets...
CVE-2014-1966
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service device outage via crafted packets...