Lucene search
K

20 matches found

GithubExploit
GithubExploit
added 2026/03/19 3:19 p.m.153 views

Exploit for Uncontrolled Resource Consumption in Siemens 6Bk1602-0Aa12-0Tp0_Firmware

Web Exploitation Guide - Index Overview This guide provid...

10CVSS7.2AI score0.94439EPSS
Exploits434
Tenable Nessus
Tenable Nessus
added 2025/10/27 12:0 a.m.2 views

Siemens SIMATIC Devices Improper Input Validation (CVE-2024-26906)

x86/mm: Disallow vsyscall page read for copyfromkernelnofault. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503613; scriptversion"1.2";...

5.5CVSS7.3AI score0.00006EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2025/10/27 12:0 a.m.3 views

Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40978)

scsi: qedi: crash while reading debugfs attribute. The qedidbgdonotrecovercmdread function invokes sprintf directly on a user pointer, which results into the crash. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...

7.1CVSS6.7AI score0.00007EPSS
Exploits0References5
CNNVD
CNNVD
added 2025/05/13 12:0 a.m.1 views

Siemens MS/TP Point Pickup Module 输入验证错误漏洞

The Siemens MS/TP Point Pickup Module is a BACnet MS/TP protocol signal acquisition conversion module from Siemens, Germany. An input validation error vulnerability exists in the Siemens MS/TP Point Pickup Module that stems from improper handling of BACnet MSTP messages, which could result in a...

7.1CVSS6.5AI score0.00132EPSS
Exploits0References1
CNNVD
CNNVD
added 2025/05/13 12:0 a.m.2 views

Siemens OZW672 操作系统命令注入漏洞

The OZW device web server is used for remote monitoring of building controller devices, e.g. for monitoring heating control or air conditioning status. A code execution and SQL injection vulnerability exists in the Siemens OZW672 and OZW772 web servers, which can be exploited by an attacker to...

10CVSS9AI score0.01106EPSS
Exploits0References1
CNNVD
CNNVD
added 2024/12/10 12:0 a.m.2 views

Siemens CPCI85 Central Processing 安全漏洞

The SICAM A8000 RTU Remote Terminal Unit is a modular device for remote control and automation applications in all areas of energy supply. A firmware decryption vulnerability exists in the Siemens SICAM A8000 CP-8031 and CP-8050 due to the fact that the affected devices contain a secure element...

5.1CVSS7.2AI score0.00212EPSS
Exploits1References1
CNNVD
CNNVD
added 2022/07/12 12:0 a.m.2 views

Siemens SICAM A8000 CP-8000 资源管理错误漏洞

The SICAM A8000 RTU Remote Terminal Unit series is a modular device family for remote control and automation applications in all areas of energy supply.A security vulnerability exists in the Siemens SICAM A8000 CPC80, which stems from the fact that when using an HTTPS server under certain...

7.5CVSS5.7AI score0.01394EPSS
Exploits0References4
CNNVD
CNNVD
added 2022/05/12 12:0 a.m.2 views

Siemens SICAM T 安全漏洞

The SICAM P850 Multifunctional Measurement Device is used to collect, visualize, evaluate and transmit electrical measurement variables such as AC current, AC voltage, frequency, power, harmonics, etc. The SICAM P855 Multifunctional Device is used to collect, display and transmit measured...

9.8CVSS8.9AI score0.03324EPSS
Exploits0References7
GithubExploit
GithubExploit
added 2021/12/13 4:41 p.m.27 views

Exploit for Uncontrolled Resource Consumption in Siemens 6Bk1602-0Aa12-0Tp0_Firmware

Ansible role - log4shell !Maintainerhttps://img.shields.io...

10CVSS8.6AI score0.94358EPSS
Exploits343
GithubExploit
GithubExploit
added 2021/12/10 5:24 p.m.43 views

Exploit for Uncontrolled Resource Consumption in Siemens 6Bk1602-0Aa12-0Tp0_Firmware

CVE-2021-44228 checker This is the repository for checking fo...

10CVSS7.5AI score0.94358EPSS
Exploits343
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.16 views

Siemens WIN5100 Communications Adapter Detection

Binary data 762032.prm...

7.3AI score
Exploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.8 views

Siemens SIPLUS EM 1SI RS232/422 Detection

Binary data 750333.prm...

7.3AI score
Exploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.9 views

Siemens X200IRT Switch Detection

Binary data 762295.prm...

7.3AI score
Exploits0
CNVD
CNVD
added 2019/01/10 12:0 a.m.3 views

SIEMENS CP1604 and CP1616 Device Cross-Site Request Forgery Vulnerability

The SIEMENS CP1604 is used to connect a PCI-104 system to PROFINET IO.The SIEMENS CP1616 is an innovative product that is installed in a PC for PROFINET communication. A cross-site request forgery vulnerability exists in the SIEMENS CP1604 and CP1616 devices. Allows an attacker to trigger an...

6.5CVSS6.9AI score0.00165EPSS
Exploits0References1
CNVD
CNVD
added 2018/12/14 12:0 a.m.2 views

Siemens TIM 1531 IRC Authentication Vulnerability

The Siemens TIM 1531 IRC is a communication module from Siemens, Germany. A security vulnerability exists in the Siemens TIM 1531 IRC prior to version 2.0, which originates from the device failing to properly authenticate itself when connecting on port 102/tcp. An attacker could use this...

10CVSS6.9AI score0.02916EPSS
Exploits0References1
Tenable Nessus
Tenable Nessus
added 2017/08/14 12:0 a.m.14 views

Siemens S7-1200 Device State Change Request Detected

Binary data 700180.prm...

7.3AI score
Exploits0
OSV
OSV
added 2017/07/07 5:29 p.m.2 views

CVE-2017-6868

An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process CP of the RNA series module, if network access to Port 102/TCP is available a...

8.1CVSS5.8AI score
Exploits0References4
CNVD
CNVD
added 2016/11/21 12:0 a.m.1 views

SIEMENS SIMATIC CP 1543-1 Device Privilege Elevation Vulnerability

The SIEMENS SIMATIC CP 1543-1 is a communication processor with integrated firewall, VPN, security protocols, data encryption, and other security features that provides network connectivity and secure communication for s7-1500 controllers. An elevation of privilege vulnerability exists in the...

6.6CVSS7.5AI score0.00745EPSS
Exploits0References1
BDU FSTEC
BDU FSTEC
added 2015/06/15 12:0 a.m.3 views

The vulnerability of Siemens Ruggedcom WIN51 microprogrammed software allows a intruder to gain access to the switch with administrator privileges.

The vulnerability of Siemens Ruggedcom WIN51 microprogrammed software allows a malicious actor to bypass authentication procedures when using remote control services and gain access to the switch with administrator privileges...

10CVSS5.5AI score0.03435EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2013/06/24 12:0 a.m.12 views

Siemens Device Detection

Binary data 6893.prm...

7.3AI score
Exploits0
Rows per page
Query Builder