912 matches found
The Siemens power monitoring system there are two information disclosure security vulnerability-vulnerability warning-the black bar safety net
Positive Technologies security experts to review Siemens SICAM PASpower automation systemafter the solution is found, Siemens SICAM PAS, the presence of two information disclosure VulnerabilityCVE-2 0 1 6-5 ! Security experts to the West door company to report a safety issue, Siemens immediately...
CVE-2016-5849
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage...
CVE-2016-5849
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage...
CVE-2016-5848
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges...
CVE-2016-5848
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges...
Design/Logic Flaw
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage...
Default credentials
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges...
CVE-2016-5848
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges...
CVE-2016-5849
CVE-2016-5849 affects Siemens SICAM PAS up to version 8.07, where an authenticated local attacker can obtain sensitive configuration information from the SICAM PAS database file if the database is in a stopped state. The issue is an information exposure vulnerability (not remote-exploit) requirin...
CVE-2016-5848
CVE-2016-5848 affects Siemens SICAM PAS (Power Automation System) prior to version 8.08. The root cause is insufficiently protected credentials in the SICAM PAS database, enabling an authenticated local attacker with certain privileges to reconstruct user passwords. A related information-disclosu...
CVE-2016-5849
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage...
CVE-2016-5849: Exposure of Sensitive Information to an Unauthorized Actor
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage...
CVE-2016-5848: Exposure of Sensitive Information to an Unauthorized Actor
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges...
Siemens Patches Password Reconstruction Vulnerability in SICAM PAS
The Industrial Control Systems Cyber Emergency Response Team ICS-CERT cautioned users who work in electrical substations to update certain builds of energy automation software this week. ICS-CERT claims two vulnerabilities exist in the Siemens SICAM Power Automation System, or PAS, that could...
Siemens SICAM PAS Information Disclosure Vulnerability (CNVD-2016-04434)
SICAM PAS is an energy automation solution for the operation of substation equipment. It has open communication interfaces for power system control and control of industrial power supply equipment. An information disclosure vulnerability exists in Siemens SICAM PAS. An authenticated, local attack...
Siemens SICAM PAS Information Disclosure Vulnerabilities (Update B)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-182-02A Siemens SICAM PAS Vulnerabilities that was published November 29, 2016, on the NCCIC/ICS-CERT web site. Positive Technologies’ Ilya Karpov and Dmitry Sklyarov have identified two vulnerabilities in the...
Siemens SICAM PAS Information Disclosure Vulnerabilities (Update B)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-182-02A Siemens SICAM PAS Vulnerabilities that was published November 29, 2016, on the NCCIC/ICS-CERT web site. Positive Technologies’ Ilya Karpov and Dmitry Sklyarov have identified two vulnerabilities in the...
PT-2016-33: Privilege Gaining in Siemens SICAM PAS
The specialists of the Positive Research center have detected a Privilege Gaining vulnerability in Siemens SICAM PAS. SICAM PAS has a factory account with hardcoded passwords, which allows attackers to gain privileged access to the database via TCP port 2638. How to fix Update your software up to...
PT-2016-29: Information Disclosure in Siemens SICAM PAS
The specialists of the Positive Research center have detected an Information Disclosure vulnerability in Siemens SICAM PAS. Siemens SICAM PAS allows local users to obtain sensitive configuration information by leveraging database stoppage. How to fix Please contact the Siemens Energy Customer...
PT-2016-3179 · Siemens · Siemens Sicam Pas
Name of the Vulnerable Software and Affected Versions: Siemens SICAM PAS versions prior to 8.07 Description: The issue is related to insufficient password protection in databases, which could allow a local attacker with certain database privileges to calculate passwords. Additionally, it may enab...