Cross site scripting
A vulnerability has been identified in SICAM GridEdge Essential ARM All versions V2.6.6, SICAM GridEdge Essential Intel All versions V2.6.6, SICAM GridEdge Essential with GDS ARM All versions V2.6.6, SICAM GridEdge Essential with GDS Intel All versions V2.6.6. The affected software does not apply...
CVE-2022-30231
CVE-2022-30231 affects Siemens SICAM GridEdge Essential products (ARM/Intel variants, with/without GDS) and SICAM GridEdge Classic in affected ranges, where prior to v2.6.6 a resource-leak exposes password hashes of other users upon request. The vulnerability enables an authenticated user to retr...
CVE-2022-30231
A vulnerability has been identified in SICAM GridEdge Classic All versions V2.6.6. The affected application discloses password hashes of other users upon request. This could allow an authenticated user to retrieve another user's password hash...
CVE-2022-30230
CVE-2022-30230 affects Siemens SICAM GridEdge components (Essential ARM/Intel, with/without GDS) prior to version 2.6.6. The vulnerability arises from missing authentication for privileged functions, allowing an unauthenticated attacker to create a new user with administrative permissions. The is...
CVE-2022-30230
A vulnerability has been identified in SICAM GridEdge Classic All versions V2.6.6. The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions...
CVE-2022-30229
A vulnerability has been identified in SICAM GridEdge Classic All versions V2.6.6. The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of a user, such as credentials, in case that user's id is known...
CVE-2022-30229
CVE-2022-30229 affects Siemens SICAM GridEdge (Classic) and related variants prior to v2.6.6, where the product does not require authentication for privileged functions. An unauthenticated attacker could alter user data (e.g., credentials) if the user ID is known. The CVSS details in public recor...
CVE-2022-30228
CVE-2022-30228 affects Siemens SICAM GridEdge Classic (all versions
CVE-2022-30228
A vulnerability has been identified in SICAM GridEdge Classic All versions V2.6.6. The affected software does not apply cross-origin resource sharing CORS restrictions for critical operations. In case an attacker tricks a legitimate user into accessing a special resource a malicious request could...
Siemens SICAM GridEdge Essential 安全漏洞
SICAM GridEdge enables your existing IEC61850 devices to have IoT functionality with just a few clicks.A resource leak vulnerability exists in Siemens SICAM GridEdge, which stems from the fact that the affected software discloses the password hash of another user upon request, which can be...
Siemens SICAM GridEdge Essential 授权问题漏洞
SICAM GridEdge enables IoT functionality in your existing IEC 61850 devices with just a few clicks.Siemens SICAM GridEdge is vulnerable to an authentication error, which stems from the fact that the affected software does not require authenticated access to privileged functions and can be exploit...
Siemens SICAM GridEdge Essential 访问控制错误漏洞
SICAM GridEdge enables IoT functionality in your existing IEC 61850 devices with just a few clicks.An authentication error vulnerability in Siemens SICAM GridEdge results from the fact that the affected software does not authenticate access to privileged functions, which can be exploited to creat...
Siemens SICAM GridEdge
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SICAM GridEdge Essential ARM Vulnerabilities: Missing Authentication for Critical Function, Resource Leak 2. RISK EVALUATION Successful exploitation of these vulnerabilities could...
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices lies in the lack of protective measures for the website structure, allowing attackers to carry out cross-site scripting attacks.
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multi-functional measuring devices is related to the lack of measures taken to protect the website structure. Exploiting this vulnerability could allow a remote attacker to perform cross-site scripting attacks...
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices lies in the insufficient cleaning of user data in the GET request parameter, allowing attackers to perform cross-site scripting attacks.
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices lies in insufficient cleaning of user data in the GET request parameter. Exploiting this vulnerability allows a remote attacker to perform cross-site scripting attacks using a specially created link...
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices, which stems from the transmission of data in an open manner via the HTTP protocol, allows attackers to intercept traffic and disrupt the operation of the devices.
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices lies in the transmission of data in an open manner via the HTTP protocol. Exploiting this vulnerability can allow a remote attacker to intercept traffic and disrupt the operation of the device...
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices lies in their ability to bypass the authentication process using capture-replay techniques for intercepted parameters. This allows attackers to gain access to the device’s control interface.
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices lies in the ability to bypass the authentication process by using capture-replay techniques to intercept and replay captured parameters. Exploiting this vulnerability can allow an intruder to gain...
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices arises from incorrect validation of certain GET and POST requests. This allows a perpetrator to trigger a service failure or execute arbitrary code.
The vulnerability of Siemens SICAM P850 and Siemens SICAM P855 multifunctional measuring devices is related to the improper verification of certain GET and POST requests. Exploiting this vulnerability can allow an attacker to trigger service failures or execute arbitrary codes...
CVE-2022-29879
A vulnerability has been identified in SICAM T All versions V3.0. The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow authenticated users to access critical device information...
CVE-2022-29881
A vulnerability has been identified in SICAM T All versions V3.0. The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow unauthenticated users to extract internal configuration details...