Lucene search
K

29 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.4 views

EUVD-2017-2368

Malware in sbrugna...

7.8CVSS7.7AI score0.00735EPSS
Exploits1References5
EUVD
EUVD
added 2025/10/07 12:30 a.m.6 views

EUVD-2017-2370

Malware in sbrugna...

8.8CVSS8.8AI score0.02569EPSS
Exploits1References5
EUVD
EUVD
added 2025/10/07 12:30 a.m.4 views

EUVD-2017-2369

Malware in sbrugna...

8.8CVSS8.8AI score0.02569EPSS
Exploits1References5
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2017-2366

Malware in sbrugna...

7.8CVSS7.7AI score0.00735EPSS
Exploits1References5
Prion
Prion
added 2021/07/15 4:15 p.m.14 views

Design/Logic Flaw

Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...

5CVSS7.7AI score0.01317EPSS
Exploits1References2
CVE
CVE
added 2021/07/15 3:4 p.m.39 views

CVE-2020-12733

Summary of CVE-2020-12733 : A vulnerability in DEPSTECH WiFi Digital Microscope 3 (uses Shenzhen PENGLIXIN components) allows a TELNET connection using the molinkadmin password for the molink account. Documented across multiple sources (NVD, Red Hat, CVE listings, CNNVD) with consistent descripti...

7.5CVSS7.6AI score0.01317EPSS
Exploits1References2Affected Software1
Cvelist
Cvelist
added 2021/07/15 3:4 p.m.27 views

CVE-2020-12733

Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...

7.7AI score0.01317EPSS
Exploits1References2
CNVD
CNVD
added 2019/06/20 12:0 a.m.3 views

Unspecified vulnerability in SHEKAR Technology Endoscope (CNVD-2019-18874)

SHEKAR Technology Endoscope is a portable endoscopic device from SHEKAR Technology, China. A security vulnerability exists in SHEKAR Technology Endoscope. An attacker can exploit the vulnerability to modify the default SSID and password, causing users to be unable to access the device or cause...

6.5CVSS6.8AI score0.01865EPSS
Exploits1References1
CNVD
CNVD
added 2019/06/20 12:0 a.m.3 views

Unspecified Vulnerability in SHEKAR Technology Endoscope

SHEKAR Technology Endoscope is a portable endoscopic device from SHEKAR Technology, China. A security vulnerability exists in the SHEKAR Technology Endoscope. An attacker could exploit the vulnerability to obtain video content and images or cause other harm...

6.5CVSS6.8AI score0.01625EPSS
Exploits1References1
CNVD
CNVD
added 2019/06/20 12:0 a.m.5 views

SHEKAR Technology Endoscope Buffer Overflow Vulnerability (CNVD-2019-18879)

SHEKAR Technology Endoscope is a portable endoscopic device from SHEKAR Technology, China. A buffer overflow vulnerability exists in SHEKAR Technology Endoscope. The vulnerability originates when a networked system or product performs an operation on memory without properly validating data...

8.8CVSS7.4AI score0.02569EPSS
Exploits1References1
CNVD
CNVD
added 2019/06/20 12:0 a.m.3 views

SHEKAR Technology Endoscope License Issue Vulnerability

SHEKAR Technology Endoscope is a portable endoscopic device from SHEKAR Technology, China. An authorization issue vulnerability exists in SHEKAR Technology Endoscope. The vulnerability arises from a lack of authentication measures or insufficient authentication strength in a networked system or...

6.5CVSS7.1AI score0.0207EPSS
Exploits1References1
CNVD
CNVD
added 2019/06/20 12:0 a.m.2 views

SHEKAR Technology Endoscope Buffer Overflow Vulnerability

SHEKAR Technology Endoscope is a portable endoscopic device from SHEKAR Technology, China. A buffer overflow vulnerability exists in SHEKAR Technology Endoscope. The vulnerability originates when a networked system or product performs an operation on memory without properly validating data...

7.8CVSS7.4AI score0.00735EPSS
Exploits1References1
NVD
NVD
added 2019/06/17 10:15 p.m.21 views

CVE-2017-10723

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows...

8.8CVSS9.2AI score0.02569EPSS
Exploits1References3
NVD
NVD
added 2019/06/17 10:15 p.m.19 views

CVE-2017-10721

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has Telnet functionality enabled by default. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car...

6.5CVSS6.5AI score0.01625EPSS
Exploits1References3
NVD
NVD
added 2019/06/17 10:15 p.m.18 views

CVE-2017-10722

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is...

7.8CVSS8AI score0.00735EPSS
Exploits1References3
NVD
NVD
added 2019/06/17 10:15 p.m.18 views

CVE-2017-10724

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows...

8.8CVSS9.2AI score0.02569EPSS
Exploits1References3
NVD
NVD
added 2019/06/17 10:15 p.m.18 views

CVE-2017-10718

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that any malicious user connecting to the device can change the default SSID and password thereby denying the owner an access to his/her own device. This device acts as an Endoscop...

6.5CVSS6.6AI score0.01865EPSS
Exploits1References3
Prion
Prion
added 2019/06/17 10:15 p.m.12 views

Design/Logic Flaw

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has Telnet functionality enabled by default. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car...

4CVSS6.4AI score0.01625EPSS
Exploits1References3
Prion
Prion
added 2019/06/17 10:15 p.m.12 views

Stack overflow

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is...

4.6CVSS8AI score0.00735EPSS
Exploits1References3
Cvelist
Cvelist
added 2019/06/17 9:39 p.m.25 views

CVE-2017-10722

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is...

8AI score0.00735EPSS
Exploits1References3
Rows per page
Query Builder