Lucene search
+L

12 matches found

NVD
NVD
•added 2020/05/07 9:15 p.m.•21 views

CVE-2020-9474

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 allows remote code execution via the backup functionality in the web frontend. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

9CVSS9AI score0.01945EPSS
SaveExploits1References1
NVD
NVD
•added 2020/05/07 9:15 p.m.•21 views

CVE-2020-9475

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 allows local privilege escalation via a race condition in logrotate. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

7CVSS6.9AI score0.00264EPSS
SaveExploits1References1
Prion
Prion
•added 2020/05/07 9:15 p.m.•22 views

Race condition

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 allows local privilege escalation via a race condition in logrotate. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

6.9CVSS6.8AI score0.00264EPSS
SaveExploits1References1Affected Software1
Prion
Prion
•added 2020/05/07 9:15 p.m.•21 views

Remote code execution

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 allows remote code execution via the backup functionality in the web frontend. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

9CVSS8.9AI score0.01945EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
•added 2020/05/07 8:29 p.m.•28 views

CVE-2020-9475

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 allows local privilege escalation via a race condition in logrotate. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

6.9AI score0.00264EPSS
SaveExploits1References1
CVE
CVE
•added 2020/05/07 8:22 p.m.•81 views

CVE-2020-9474

The SG 150-0 Smart Gateway from S.Siedle & Soehne is affected prior to version 1.2.4. A remote code execution exists via the backup function in the web frontend, and an attacker with network access can escalate to root on the gateway. Remediation: upgrade to version 1.2.4 or later (as cited in CN...

9CVSS8.9AI score0.01945EPSS
SaveExploits1References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/05/07 12:00 a.m.•5 views

CVE-2020-9475: Concurrent Execution using Shared Resource with Improper Synchronization

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 allows local privilege escalation via a race condition in logrotate. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

7CVSS6.9AI score0.00264EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/05/07 12:00 a.m.•4 views

CVE-2020-9474: Download of Code Without Integrity Check

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 allows remote code execution via the backup functionality in the web frontend. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

9CVSS8.3AI score0.01945EPSS
SaveExploits1References2
NVD
NVD
•added 2020/04/06 3:15 p.m.•22 views

CVE-2020-9473

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 has a passwordless ftp ssh user. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

8.5CVSS6.4AI score0.01012EPSS
SaveExploits1References1
CVE
CVE
•added 2020/04/06 2:56 p.m.•66 views

CVE-2020-9473

CVE-2020-9473 affects the S. Siedle & Soehne SG 150-0 Smart Gateway older than 1.2.4. It documents a passwordless ftp/SSH user, allowing an attacker with network access to chain exploits and achieve root access on the gateway. CVSS metrics from the sources indicate high impact (I/H, A/H) with net...

8.5CVSS7AI score0.01012EPSS
SaveExploits1References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/06 12:00 a.m.•5 views

CVE-2020-9473: Missing Authentication for Critical Function

The S. Siedle & Soehne SG 150-0 Smart Gateway before 1.2.4 has a passwordless ftp ssh user. By using an exploit chain, an attacker with access to the network can get root access on the gateway...

8.5CVSS7AI score0.01012EPSS
SaveExploits1References2
OpenVAS
OpenVAS
•added 2016/11/02 12:00 a.m.•1915 views

SSH Brute Force Logins With Default Credentials Reporting

It was possible to login into the remote SSH server using default credentials. SPDX-FileCopyrightText: 2016 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

10CVSS7.6AI score0.90155EPSS
SaveExploits69References2
Rows per page
Query Builder