14 matches found
EUVD-2026-31752
A security vulnerability has been detected in Totolink CA750-PoE 6.2c.510. Impacted is the function setNetworkDiag of the file /cgi-bin/cstecgi.cgi of the component Setting Handler. The manipulation of the argument NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop is...
EUVD-2023-28202
Malicious code in bioql PyPI...
CVE-2023-24143
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagTracertHop parameter in the setNetworkDiag function...
CVE-2023-24139
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagHost parameter in the setNetworkDiag function...
CVE-2023-24142
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingSize parameter in the setNetworkDiag function...
CVE-2023-24140
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingNum parameter in the setNetworkDiag function...
Command injection
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingNum parameter in the setNetworkDiag function...
CVE-2023-24140
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingNum parameter in the setNetworkDiag function...
CVE-2023-24142
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingSize parameter in the setNetworkDiag function...
CVE-2023-24140
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingNum parameter in the setNetworkDiag function...
CVE-2023-24143
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagTracertHop parameter in the setNetworkDiag function...
CVE-2023-24142
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagPingSize parameter in the setNetworkDiag function...
CVE-2023-24143
CVE-2023-24143 affects TOTOLINK CA300-PoE (V6.2c.884). A command injection vulnerability exists in the NetDiagTracertHop parameter of the setNetworkDiag function. The CVSS v3.1 base score is 9.8 (CRITICAL) with network access, no authentication, no user interaction required, and impacts to confid...
CVE-2023-24143
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the NetDiagTracertHop parameter in the setNetworkDiag function...