Lucene search
+L

33 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/10/07 12:00 a.m.•4 views

CVE-2025-11388: Stack-based Buffer Overflow

A vulnerability was identified in Tenda AC15 15.03.05.18. This impacts an unknown function of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used...

9CVSS8.3AI score0.00799EPSS
SaveExploits1References6
CNNVD
CNNVD
•added 2025/10/07 12:00 a.m.•17 views

Tenda AC15 安全漏洞

Tenda AC15 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in October 2015, which supports 802.11ac protocol and is mainly designed for home network environment. Tenda AC15 has a stack buffer overflow vulnerability, which originates from the parameter newVersion i...

9CVSS8.3AI score0.00799EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2025/10/07 12:00 a.m.•18 views

PT-2025-40979

Name of the Vulnerable Software and Affected Versions Tenda AC15 version 15.03.05.18 Description A flaw exists in Tenda AC15 version 15.03.05.18 that allows remote attackers to trigger a stack-based buffer overflow. The issue is related to the manipulation of the newVersion argument within the...

9CVSS8.8AI score0.00799EPSS
SaveExploits1References10
OSV
OSV
•added 2025/10/06 7:15 a.m.•20 views

CVE-2025-11324

A vulnerability was identified in Tenda AC18 15.03.05.196318. Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is public...

8.7CVSS6.5AI score0.00827EPSS
SaveExploits1References5
NVD
NVD
•added 2025/10/06 7:15 a.m.•35 views

CVE-2025-11324

A vulnerability was identified in Tenda AC18 15.03.05.196318. Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is public...

9CVSS0.00827EPSS
SaveExploits1References5
CVE
CVE
•added 2025/10/06 6:32 a.m.•48 views

CVE-2025-11324

CVE-2025-11324 affects Tenda AC18 (firmware 15.03.05.19(6318)). The vulnerability is a stack-based buffer overflow in an unknown function within /goform/setNotUpgrade caused by improper handling of the newVersion parameter. Exploitation can be performed remotely; a public exploit exists. Affected...

9CVSS8.3AI score0.00827EPSS
SaveExploits1References5Affected Software1
Cvelist
Cvelist
•added 2025/10/06 6:32 a.m.•33 views

CVE-2025-11324 Tenda AC18 setNotUpgrade stack-based overflow

A vulnerability was identified in Tenda AC18 15.03.05.196318. Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is public...

9CVSS0.00827EPSS
SaveExploits1References5
Vulnrichment
Vulnrichment
•added 2025/10/06 6:32 a.m.•14 views

CVE-2025-11324 Tenda AC18 setNotUpgrade stack-based overflow

A vulnerability was identified in Tenda AC18 15.03.05.196318. Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is public...

9CVSS8.3AI score0.00827EPSS
SaveExploits1References5
EUVD
EUVD
•added 2025/10/06 6:32 a.m.•27 views

EUVD-2025-32512

A vulnerability was identified in Tenda AC18 15.03.05.196318. Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is public...

9CVSS6.9AI score0.00827EPSS
SaveExploits1References6
CNNVD
CNNVD
•added 2025/10/06 12:00 a.m.•19 views

Tenda AC18 安全漏洞

Tenda AC18 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in July 2016, mainly for villas and large home users. Tenda AC18 has a stack buffer overflow vulnerability, which originates from the parameter newVersion in the file /goform/setNotUpgrade fails to correct...

9CVSS8.3AI score0.00827EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•31 views

PT-2025-40855

Name of the Vulnerable Software and Affected Versions Tenda AC18 version 15.03.05.196318 Description A stack-based buffer overflow exists in an unknown functionality of the file /goform/setNotUpgrade. Manipulation of the newVersion argument can trigger this issue, allowing for remote attacks. A...

9CVSS9.1AI score0.00827EPSS
SaveExploits1References10
Positive Technologies
Positive Technologies
•added 2025/10/06 12:00 a.m.•20 views

PT-2025-41606

Name of the Vulnerable Software and Affected Versions Tenda AC7 version 15.03.06.44 Description A stack-based buffer overflow exists in the Tenda AC7 router firmware. The issue is located in an unknown function within the /goform/setNotUpgrade endpoint. Manipulation of the newVersion argument...

9.8CVSS7.9AI score0.00866EPSS
SaveExploits1References16
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/10/06 12:00 a.m.•11 views

CVE-2025-11324: Stack-based Buffer Overflow

A vulnerability was identified in Tenda AC18 15.03.05.196318. Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is public...

9CVSS8.3AI score0.00827EPSS
SaveExploits1References6
Rows per page
Query Builder