128943 matches found
CVE-2020-7134
A remote access to sensitive data vulnerability was discovered in HPE IOT + GCP versions: 1.4.0, 1.4.1, 1.4.2, 1.2.4.2...
CVE-2020-7567
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke t...
CVE-2020-7541
A CWE-425: Direct Request 'Forced Browsing' vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules see security notification for affected versions, that could cause disclosure of sensitive data when sending a...
CVE-2020-7003
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is transmitted over some web applications in clear text...
CVE-2020-7232
Evoko Home devices 1.31 through 1.37 allow remote attackers to obtain sensitive information such as usernames and password hashes via a WebSocket request, as demonstrated by the sockjs/224/uf1psgff/websocket URI at a wss:// URL...
CVE-2020-7944
In Continuous Delivery for Puppet Enterprise CD4PE before 3.4.0, changes to resources or classes containing Sensitive parameters can result in the Sensitive parameters ending up in the impact analysis report...
CVE-2020-7513
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 Firmware version 1.5.2 and older which could allow an attacker to intercept traffic and read configuration data...
CVE-2020-12004
The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway versions prior to 8.0.10 and Ignition 7 Gateway versions prior to 7.9.14, allowing an attacker to obtain sensitive information...
CVE-2020-12048
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...
CVE-2020-12051
The CentralAuth extension through REL134 for MediaWiki allows remote attackers to obtain sensitive hidden account information via an api.php?action=query=globaluserinfo= request. In other words, the information can be retrieved via the action API even though access would be denied when simply...
CVE-2020-12024
Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to th...
CVE-2020-12127
An information disclosure vulnerability in the /cgi-bin/ExportAllSettings.sh endpoint of the WAVLINK WN530H4 M30H4.V5030.190403 allows an attacker to leak router settings, including cleartext login details, DNS settings, and other sensitive information without authentication...
CVE-2020-12118
The keygen protocol implementation in Binance tss-lib before 1.2.0 allows attackers to generate crafted h1 and h2 parameters in order to compromise a signing round or obtain sensitive information from other parties...
CVE-2020-12037
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
CVE-2020-12070
The Advanced Woo Search plugin version through 1.99 for Wordpress suffers from a sensitive information disclosure vulnerability in every ajax search request via the sql field to includes/class-aws-search.php...
CVE-2020-12016
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account...
CVE-2020-12492
Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information...
CVE-2020-12478
TeamPass 2.1.27.36 allows an unauthenticated attacker to retrieve files from the TeamPass web root. This may include backups or LDAP debug files...
CVE-2020-12003
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 an...
CVE-2020-12012
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials f...