Lucene search
K

7 matches found

Positive Technologies
Positive Technologies
added 2026/01/06 12:0 a.m.2 views

PT-2026-1449

Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec...

8.7CVSS7.8AI score0.00066EPSS
Exploits1References7
OSV
OSV
added 2025/09/08 2:13 p.m.3 views

GO-2025-3930 Soft Serve vulnerable to arbitrary file writing through SSH API in github.com/charmbracelet/soft-serve

Soft Serve vulnerable to arbitrary file writing through SSH API in github.com/charmbracelet/soft-serve...

7.7CVSS6.8AI score0.00116EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2025/09/08 12:0 a.m.1 views

PT-2025-36651

Soft Serve vulnerable to arbitrary file writing through SSH API in github.com/charmbracelet/soft-serve...

7.7CVSS7AI score0.00116EPSS
Exploits0References3
NVD
NVD
added 2025/09/04 10:42 a.m.3 views

CVE-2025-58355

Soft Serve is a self-hostable Git server for the command line. In versions 0.9.1 and below, attackers can create or override arbitrary files with uncontrolled data through its SSH API. This issue is fixed in version 0.10.0...

7.7CVSS0.00116EPSS
Exploits0References1
OSV
OSV
added 2022/12/13 4:15 p.m.2 views

CVE-2022-46834

Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the...

6.5CVSS5.8AI score
Exploits0References1
CNNVD
CNNVD
added 2022/06/28 12:0 a.m.1 views

Motorola Solutions ACE1000 数据伪造问题漏洞

The Motorola Solutions ACE1000 is a remote terminal unit RTU from Motorola Solutions USA. The Motorola Solutions ACE1000 RTU is vulnerable to a data forgery issue, which arises from an attacker communicating with the Motorola ACE1000 RTU via SSH or Web UI, who could push a malicious firmware imag...

7.2CVSS7.5AI score0.00106EPSS
Exploits0References6
Sick AG
Sick AG
added 2021/06/25 10:0 a.m.5 views

Inadequate SSH configuration in SICK Visionary-S CX

SICK received a report that informed SICK about an Inadequate Encryption Strength vulnerability in the SICK product “SICK Visionary-S CX” concerning the internal SSH interface solely used by SICK for recovering returned devices. Currently SICK is not aware of any public exploits specifically...

3.7CVSS7AI score0.00072EPSS
Exploits0