34 matches found
CVE-2023-7017 CVE-2023-7017
Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to...
CVE-2023-7017
CVE-2023-7017 affects Sciener locks with BLE-based firmware updates. The vulnerability is that the firmware update mechanism does not authenticate or validate updates delivered via Bluetooth Low Energy, enabling a challenge request to be sent to the lock to prepare for an update (instead of an un...
Sciener firmware security vulnerability
Sciener is a smart lock firmware from Sciener. The Sciener firmware has a security vulnerability that stems from the fact that the AES key for the pairing between the lock and the wireless keypad is not unique and can be reused...
Sciener locks firmware security vulnerability
Sciener is a smart lock firmware from Sciener. A security vulnerability exists in the Sciener locks firmware, which stems from the fact that the firmware update mechanism does not validate the firmware update request if the firmware update is passed to the lock via the Bluetooth Low Energy servic...
Sciener-based locks Security Vulnerabilities
Sciener is a smart lock firmware from Sciener. A security vulnerability exists in Sciener-based locks that stems from support for plaintext message processing, allowing an attacker to pass unencrypted malicious commands to the lock...
PT-2024-15176 · Unknown · Sciener-Based Locks
Name of the Vulnerable Software and Affected Versions: Sciener-based locks affected versions not specified Description: The issue allows unencrypted malicious commands to be passed to the lock over Bluetooth Low Energy, as some Sciener-based locks support plaintext message processing. These...
Sciener firmware security vulnerability
Sciener is a smart lock firmware from Sciener. A security vulnerability exists in the Sciener firmware that originates from allowing an attacker to brute-force unlockKey characters...
Sciener server security vulnerability
Sciener is a smart lock firmware from Sciener. A security vulnerability exists in the Sciener server that stems from not validating connection requests from GatewayG2, which allows an attacker to obtain the unlockKey field via a simulated attack...
PT-2024-15180 · Unknown · Sciener Locks
Name of the Vulnerable Software and Affected Versions: Sciener locks affected versions not specified Description: The firmware update mechanism of the locks does not authenticate or validate firmware updates when they are passed through the Bluetooth Low Energy service. An attacker can send a...
PT-2024-15172 · Sciener · Sciener Firmware
Name of the Vulnerable Software and Affected Versions: TTLock App affected versions not specified Description: The issue arises from the TTLock App's failure to properly verify the device it is communicating with, allowing a device that spoofs the MAC address of a lock to connect and compromise t...
PT-2024-15171 · Kontrol +2 · Kontrol +3
Name of the Vulnerable Software and Affected Versions: Sciener firmware affected versions not specified Description: The issue concerns the use of a non-unique AES key in the pairing process between locks using Sciener firmware and wireless keypads. This key can be reused, potentially compromisin...
Sceiner firmware locks and associated devices are vulnerable to encryption downgrade and arbitrary file upload attacks
Overview Sciener is a company that develops software and hardware for electronic locks that are marketed under many different brands. Their hardware works in tandem with an app, called the TTLock app, which is also produced by Sciener. The TTLock app utilizes Bluetooth connections to connect to...
PT-2024-15143 · Sciener · Sciener Firmware
Name of the Vulnerable Software and Affected Versions: TTLock App affected versions not specified Description: The TTLock App has an issue where virtual keys and settings are only deleted on the client side. If these deleted items are preserved, they can still be used to access the lock after the...
PT-2024-15174 · Kontrol +2 · Kontrol +3
Name of the Vulnerable Software and Affected Versions: Sciener firmware affected versions not specified Description: The issue concerns the unlockKey character in locks using Sciener firmware, which can be compromised through brute force attacks by sending repeated challenge requests. This affect...